EFFECTS ON ERYTHROCYTE AGGREGATION AND BLOOD-COAGULATION FROM IOHEXOL SOLUTIONS WITH AND WITHOUT SODIUM-CHLORIDE - AN IN-VITRO STUDY ON THE ROLE OF ION CONCENTRATION AND OSMOLALITY

被引:0
作者
CHAI, CM [1 ]
ALMEN, T [1 ]
ASPELIN, P [1 ]
BAATH, L [1 ]
机构
[1] KAROLINSKA INST,HUDDINGE HOSP,S-14186 HUDDINGE,SWEDEN
关键词
CONTRAST MEDIA; NONIONIC; IOHEXOL; BLOOD; ERYTHROCYTE AGGREGATION; THROMBOSIS;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Solutions of the nonionic monomeric contrast medium iohexol (300 mg I/ml) with and without added NaCl were investigated for effects on red blood cell aggregation and blood coagulation. Three volumes of a test solution were mixed in test tubes with one volume of human blood. During 30 min samples of the mixture were taken for investigation. Six test solutions were used: 1) iohexol, 2) iohexol + glucose 280 mM, 3) iohexol + NaCl 150 mM, 4) glucose 280 mM, 5) glucose 140 mM + NaCl 75 mM, 6) NaCl 150 mM. Test solutions with NaCl caused no aggregation. Test solutions without NaCl always caused macroscopic red cell aggregates. These aggregates always disappeared when saline was added to the sample. The macroscopic red cell aggregates could be dispersed to microscopic aggregates by shaking the test tubes. During the next 30 min macroscopic aggregates returned in the glucose solution but not in the iohexol solutions. In 30 min, blood mixed with iohexol solutions never coagulated while blood layered on top of the same iohexol solutions always coagulated. Blood mixed with solutions 5 and 6, both without iohexol, always coagulated. It is concluded that adding 150 mM NaCl to iohexol did not eliminate its ability to anticoagulate whole blood, but inhibited its ability to aggregate red cells. This inhibition was not caused by the osmotic effects of the added NaCl.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 33 条
  • [1] DO NONIONIC CONTRAST-MEDIA INCREASE RED-CELL AGGREGATION AND CLOT FORMATION
    ASPELIN, P
    SCHMIDSCHONBEIN, H
    MALOTTA, H
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 : S326 - S333
  • [2] EFFECT OF IONIC AND NONIONIC CONTRAST-MEDIA ON RED-CELL AGGREGATION INVITRO
    ASPELIN, P
    SCHMIDSCHONBEIN, H
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1978, 19 (05): : 766 - 784
  • [3] ASPELIN P, 1989, PATIENT SAFETY ADVER, P79
  • [4] BAATH L, 1990, ACTA RADIOL, V31, P99
  • [5] NON-IONIC CONTRAST AGENTS, RED-CELL AGGREGATION AND COAGULATION
    DAWSON, P
    MCCARTHY, P
    ALLISON, DJ
    GARVEY, B
    BRADSHAW, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (730) : 963 - 965
  • [6] THE NEW LOW-OSMOLAR CONTRAST-MEDIA - A SIMPLE GUIDE
    DAWSON, P
    GRAINGER, RG
    PITFIELD, J
    [J]. CLINICAL RADIOLOGY, 1983, 34 (02) : 221 - 226
  • [7] CONTRAST, COAGULATION, AND FIBRINOLYSIS
    DAWSON, P
    HEWITT, P
    MACKIE, IJ
    MACHIN, SJ
    AMIN, S
    BRADSHAW, A
    [J]. INVESTIGATIVE RADIOLOGY, 1986, 21 (03) : 248 - 252
  • [8] BLOOD-CELL AGGREGATES WITH LOW-OSMOLALITY AND NONIONIC CONTRAST-MEDIA
    FISCHER, HW
    MORRIS, TW
    [J]. RADIOLOGY, 1987, 165 (02) : 583 - 583
  • [9] THROMBOEMBOLIC COMPLICATIONS IN CORONARY ANGIOGRAPHY ASSOCIATED WITH THE USE OF NONIONIC CONTRAST-MEDIUM
    GROLLMAN, JH
    LIU, CK
    ASTONE, RA
    LURIE, MD
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 14 (03): : 159 - 164
  • [10] THE EFFECT OF LOW-OSMOLAR IONIC AND NONIONIC CONTRAST-MEDIA ON HUMAN BLOOD-VISCOSITY, ERYTHROCYTE MORPHOLOGY, AND AGGREGATION BEHAVIOR
    HARDEMAN, MR
    GOEDHART, P
    KOEN, IY
    [J]. INVESTIGATIVE RADIOLOGY, 1991, 26 (09) : 810 - 819