CEREBRAL EMBOLISM DUE TO LEFT-VENTRICULAR PACEMAKER LEAD - REMOVAL WITH CARDIOPULMONARY BYPASS

被引:17
作者
LIEBOLD, A [1 ]
AEBERT, H [1 ]
MUSCHOLL, M [1 ]
BIRNBAUM, DE [1 ]
机构
[1] KLINIKUM UNIV REGENSBURG,DEPT CARDIOL,D-93042 REGENSBURG,GERMANY
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1994年 / 17卷 / 12期
关键词
CARDIAC PACEMAKER; LEAD MISPLACEMENT; CEREBRAL EMBOLISM; CARDIOPULMONARY BYPASS;
D O I
10.1111/j.1540-8159.1994.tb02387.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Malposition of a cardiac pacemaker lead within the left ventricle represents a source of early and late thromboembolic complications. We report a case of cerebral embolism, caused by an inadvertently misplaced left ventricular electrode, occurring 3 years after implantation. The lead was removed via a transaortic approach with extracorporeal circulation.
引用
收藏
页码:2353 / 2355
页数:3
相关论文
共 40 条
  • [21] Heparin-induced thrombocytopenia, left ventricular thrombus and cerebral embolism in the course of myocardial infarction
    Jakobs, D
    MEDIZINISCHE KLINIK, 2001, 96 (02) : 101 - 104
  • [22] Cardiopulmonary bypass and left ventricular systolic dysfunction impacts operative mortality differently in elderly and young patients
    Ngaage, Dumbor L.
    Cowen, Michael E.
    Cate, Alexander R.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (02) : 235 - 240
  • [23] Comparison between normothermic and mild hypothermic cardiopulmonary bypass in myocardial revascularization of patients with left ventricular dysfunction
    Yuksel, V.
    Canbaz, S.
    Ege, T.
    PERFUSION-UK, 2013, 28 (05): : 419 - 423
  • [24] In vitro air removal characteristics of two neonatal cardiopulmonary bypass systems: filtration may lead to fractionation of bubbles
    Stehouwer, Marco C.
    Kelder, Johannes C.
    van Oeveren, Willem
    de Vroege, Roel
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (09) : 688 - 696
  • [25] Comparison of myocardial revascularization without cardiopulmonary bypass to standard open heart technique in patients with left ventricular dysfunction
    Sternik, L
    Moshkovitz, Y
    Hod, H
    Mohr, R
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (01) : 123 - 128
  • [26] CASE 13-2016 Minimally Invasive Left Ventricular Assist Device Insertion Without Cardiopulmonary Bypass
    Bienia, Sebastian
    Feider, Andrew
    Griauzde, Rima
    Patel, Komal D.
    Minhaj, Mohammed M.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (06) : 1716 - 1726
  • [27] REMOVAL OF INFECTED DUAL CHAMBERED TRANSVENOUS PACEMAKER AND IMPLANTATION OF A NEW EPICARDIAL DUAL CHAMBERED DEVICE WITH CARDIOPULMONARY BYPASS - EXPERIENCE WITH 7 CASES
    ABAD, C
    MANZANO, JJ
    QUINTANA, J
    BOLANOS, J
    MANZANO, JL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (06): : 1272 - 1275
  • [28] A single dose of milrinone facilitates separation from cardiopulmonary bypass in patients with pre-existing left ventricular dysfunction
    Lobato, EB
    Florete, O
    Bingham, HL
    BRITISH JOURNAL OF ANAESTHESIA, 1998, 81 (05) : 782 - 784
  • [29] Left ventricular thrombosis caused cerebral embolism during venoarterial extracorporeal membrane oxygenation support: A case report
    Bai, Yao-Bang
    Zhao, Feng
    Wu, Zhen-Hua
    Shi, Guo-Ning
    Jiang, Nan
    WORLD JOURNAL OF CLINICAL CASES, 2024, 12 (05)
  • [30] A Nonocclusive, Inexpensive Pediatric Pulsatile Roller Pump for Cardiopulmonary Bypass, Extracorporeal Life Support, and Left/Right Ventricular Assist Systems
    Wang, Shigang
    Durandy, Yves
    Kunselman, Allen R.
    Uendar, Akif
    ARTIFICIAL ORGANS, 2013, 37 (01) : 48 - 56