Influence of Global and Local Membrane Curvature on Mechanosensitive Ion Channels: A Finite Element Approach

被引:52
作者
Bavi, Omid [1 ,2 ]
Cox, Charles D. [2 ]
Vossoughi, Manouchehr [1 ,3 ]
Naghdabadi, Reza [1 ,4 ]
Jamali, Yousef [5 ,6 ]
Martinac, Boris [2 ,7 ]
机构
[1] Sharif Univ Technol, Inst Nanosci & Nanotechnol, Tehran 8969414588, Iran
[2] Victor Chang Cardiac Res Inst, Mol Cardiol & Biophys Div, Mechanosensory Biophys Lab, Darlinghurst, NSW 2010, Australia
[3] Biochem & Bioenvironm Res Ctr, Tehran 8969414588, Iran
[4] Sharif Univ Technol, Dept Mech Engn, Tehran 8969414588, Iran
[5] Tarbiat Modares Univ, Dept Math & Biosci, Jalal Ale Ahmad Highway, Tehran 14115111, Iran
[6] Inst Res Fundamental Sci IPM, Sch Nanosci, Computat Phys Sci Res Lab, Tehran 193955531, Iran
[7] Univ New S Wales, Fac Med, St Vincents Clin Sch, Darlinghurst, NSW 2010, Australia
关键词
local bending; mechanosensitive ion channel; continuum mechanics; membrane local curvature; finite element;
D O I
10.3390/membranes6010014
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Mechanosensitive (MS) channels are ubiquitous molecular force sensors that respond to a number of different mechanical stimuli including tensile, compressive and shear stress. MS channels are also proposed to be molecular curvature sensors gating in response to bending in their local environment. One of the main mechanisms to functionally study these channels is the patch clamp technique. However, the patch of membrane surveyed using this methodology is far from physiological. Here we use continuum mechanics to probe the question of how curvature, in a standard patch clamp experiment, at different length scales (global and local) affects a model MS channel. Firstly, to increase the accuracy of the Laplace's equation in tension estimation in a patch membrane and to be able to more precisely describe the transient phenomena happening during patch clamping, we propose a modified Laplace's equation. Most importantly, we unambiguously show that the global curvature of a patch, which is visible under the microscope during patch clamp experiments, is of negligible energetic consequence for activation of an MS channel in a model membrane. However, the local curvature (R-L < 50) and the direction of bending are able to cause considerable changes in the stress distribution through the thickness of the membrane. Not only does local bending, in the order of physiologically relevant curvatures, cause a substantial change in the pressure profile but it also significantly modifies the stress distribution in response to force application. Understanding these stress variations in regions of high local bending is essential for a complete understanding of the effects of curvature on MS channels.
引用
收藏
页数:16
相关论文
共 54 条
[1]   Lipid-protein interactions: Lessons learned from stress [J].
Battle, A. R. ;
Ridone, P. ;
Bavi, N. ;
Nakayama, Y. ;
Nikolaev, Y. A. ;
Martinac, B. .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2015, 1848 (09) :1744-1756
[2]   Biophysical implications of lipid bilayer rheometry for mechanosensitive channels [J].
Bavi, Navid ;
Nakayama, Yoshitaka ;
Bavi, Omid ;
Cox, Charles D. ;
Qin, Qing-Hua ;
Martinac, Boris .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2014, 111 (38) :13864-13869
[3]   Gating Mechanism of Mechanosensitive Ion Channels Studied by Continuum Mechanics [J].
Bavi, Navid ;
Nomura, Takeshi ;
Qin, Qinghua ;
Martinac, Boris .
BIOPHYSICAL JOURNAL, 2014, 106 (02) :554A-555A
[4]   The effect of local bending on gating of MscL using a representative volume element and finite element simulation [J].
Bavi, Omid ;
Vossoughi, Manouchehr ;
Naghdabadi, Reza ;
Jamali, Yousef .
CHANNELS, 2014, 8 (04) :344-349
[5]   The Purified Mechanosensitive Channel TREK-1 Is Directly Sensitive to Membrane Tension [J].
Berrier, Catherine ;
Pozza, Alexandre ;
de lavalette, Agnes de Lacroix ;
Chardonnet, Solenne ;
Mesneau, Agnes ;
Jaxel, Christine ;
le Maire, Marc ;
Ghazi, Alexandre .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2013, 288 (38) :27307-27314
[6]   High-speed pressure clamp [J].
Besch, SR ;
Suchyna, T ;
Sachs, F .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2002, 445 (01) :161-166
[7]   The Structure of YnaI Implies Structural and Mechanistic Conservation in the MscS Family of Mechanosensitive Channels [J].
Boettcher, Bettina ;
Prazak, Vojtech ;
Rasmussen, Akiko ;
Black, Susan S. ;
Rasmussen, Tim .
STRUCTURE, 2015, 23 (09) :1705-1714
[8]   The MscS and MscL Families of Mechanosensitive Channels Act as Microbial Emergency Release Valves [J].
Booth, Ian R. ;
Blount, Paul .
JOURNAL OF BACTERIOLOGY, 2012, 194 (18) :4802-4809
[9]   Physical mechanism for gating and mechano sensitivity of the human TRAAK K+ channel [J].
Brohawn, Stephen G. ;
Campbell, Ernest B. ;
MacKinnon, Roderick .
NATURE, 2014, 516 (7529) :126-U345
[10]   Mechanosensitivity is mediated directly by the lipid membrane in TRAAK and TREK1 K+ channels [J].
Brohawn, Stephen G. ;
Su, Zhenwei ;
MacKinnon, Roderick .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2014, 111 (09) :3614-3619