SENSITIVE RADIOIMMUNOASSAY FOR THE DETERMINATION OF PLASMA ANGIOTENSIN-II IN HUMAN-SUBJECTS

被引:17
作者
KOBAYASHI, H
SHIMAMOTO, K
MORIGUCHI, O
MIYAHARA, M
机构
[1] Second Department of Internal Medicine, Sapporo Medical College, S-l W-16, Sapporo
来源
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION | 1979年 / 43卷 / 08期
关键词
Plasma angiotensin II concentration; Radioimmunoassay;
D O I
10.1253/jcj.43.727
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
A sensitive and specific radioimmunoassay for the determination of plasma angiotensin II was developed by using the antisera against synthetic angiotensin II in combination with labeled angiotensin II. This assay employs an acetone extraction procedure and detects as little as 0.8 pg per tube of angiotensin II. The mean (±S.E.) plasma angiotensin II concentration in 19 normal subjects was 14.4 ± 1.8 pg/ml in a state of overnight fasting and recumbency. In 13 normal subjects, in whom 40 mg of furosemide was injected intravenously, plasma angiotensin II concentration before and after 30 and 120 minutes in an upright position was 14.6 ±2.2, 56.6 ±5.7 and 74.3 ± 9.0 pg/ml, respectively. In 6 normal subjects, an infusion of isotonic saline, angiotensin II concentration reduced from 14.1 ± 3.7 to 9.2 ± 1.7 pg/ml. Thus, it was ascertained that the simplified radioimmunoassay method reported here using an acetone-petroleum ether extraction method was specific and highly sensitive. © 1979, The Japanese Circulation Society. All rights reserved.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 26 条
[1]  
BARRETT JD, 1977, CLIN CHEM, V23, P464
[2]   RADIOIMMUNOASSAY OF ANGIOTENSIN-2 [J].
BOYD, GW ;
LANDON, J ;
PEART, WS .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1969, 173 (1032) :327-+
[3]  
BOYD GW, 1967, LANCET, V2, P1002
[4]   MEASUREMENT OF ANGIOTENSIN-II IN BLOOD BY RADIOIMMUNOASSAY [J].
CAIN, MD ;
CATT, KJ ;
COGHLAN, JP .
CLINICA CHIMICA ACTA, 1972, 39 (01) :21-+
[5]   BLOOD ANGIOTENSIN 2 LEVELS OF NORMAL AND HYPERTENSIVE SUBJECTS [J].
CATT, KJ ;
CAIN, MD ;
ZIMMET, PZ ;
CRAN, E .
BRITISH MEDICAL JOURNAL, 1969, 1 (5647) :819-&
[6]  
CATT KJ, 1967, LANCET, V2, P1005
[7]  
CATT KJ, 1971, LANCET, V1, P459
[8]   USE OF POLYETHYLENE GLYCOL TO SEPARATE FREE AND ANTIBODY-BOUND PEPTIDE HORMONES IN RADIOIMMUNOASSAYS [J].
DESBUQUOIS, B ;
AURBACH, GD .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1971, 33 (05) :732-+
[9]   ESTIMATION OF ANGIOTENSIN II CONCENTRATION IN HUMAN PLASMA BY RADIOIMMUNOASSAY - SOME APPLICATIONS TO PHYSIOLOGICAL AND CLINICAL STATES [J].
DUSTERDIECK, G ;
MCELWEE, G .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1971, 2 (01) :32-+
[10]  
EMANUEL RL, 1973, J LAB CLIN MED, V81, P632