STORAGE-CONDITIONS OF BLOOD-SAMPLES AND PRIMER SELECTION AFFECT THE YIELD OF CDNA POLYMERASE CHAIN-REACTION PRODUCTS OF HEPATITIS-C VIRUS

被引:110
作者
CUYPERS, HTM
BRESTERS, D
WINKEL, IN
REESINK, HW
WEINER, AJ
HOUGHTON, M
VANDERPOEL, CL
LESLIE, PN
机构
[1] RED CROSS BLOOD BANK,AMSTERDAM,NETHERLANDS
[2] CHIRON CORP,EMERYVILLE,CA 94608
关键词
D O I
10.1128/JCM.30.12.3220-3224.1992
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We have noticed that suboptimal specimen processing and storage conditions may cause false-negative results in the detection of hepatitis C virus (HCV) RNA in plasma or serum. To establish the influence of specimen handling in a serological laboratory on the rate of detection of HCV RNA by the cDNA polymerase chain reaction (cDNA-PCR), we tested routine serum samples and fresh-frozen plasma samples from the same bleeding from confirmed anti-HCV-positive blood donors. When primers from the NS3/NS4 region were used, HCV RNA was detected in fresh-frozen plasma from 67% of the donors, whereas positive results were obtained with only 50% of the serum samples that had been subjected to routine serotogical procedures. Analysis of the same samples with primers from the highly conserved 5'-terminal region (5'-TR) revealed an HCV RNA detection rate of 92% for both the routine and the fresh-frozen samples. However, the yield of the amplification product in routine samples was strongly reduced compared with that in fresh-frozen plasma. Comparison of both primer sets for cDNA-PCR showed that the 5'-TR primer set was 10- to 100-fold more effective in detecting HCV RNA. We also analyzed the effect of storage of whole EDTA-blood and serum at room temperature and at 4-degrees-C on the yield of the amplification product. A rapid decline in detectable HCV RNA of 3 to 4 log units was observed within 14 days when whole blood and serum were stored at room temperature. By contrast, no perceptible reduction in the cDNA-PCR signal was found in freshly prepared serum stored at 4-degrees-C.
引用
收藏
页码:3220 / 3224
页数:5
相关论文
共 24 条
[1]   THE USE OF A RECOMBINANT IMMUNOBLOT ASSAY IN THE INTERPRETATION OF ANTI-HEPATITIS-C VIRUS REACTIVITY AMONG PROSPECTIVELY FOLLOWED PATIENTS, IMPLICATED DONORS, AND RANDOM DONORS [J].
ALTER, HJ ;
TEGTMEIER, GE ;
JETT, BW ;
QUAN, S ;
SHIH, JW ;
BAYER, WL ;
POLITO, A .
TRANSFUSION, 1991, 31 (08) :771-776
[2]  
BAGGIOLINI M, 1985, INT ARCH ALLER A IMM, V76, P143
[3]   DISAPPEARANCE OF HEPATITIS-C VIRUS-RNA IN PLASMA DURING INTERFERON-ALPHA-2B TREATMENT IN HEMOPHILIA PATIENTS [J].
BRESTERS, D ;
MAUSERBUNSCHOTEN, EP ;
CUYPERS, HTM ;
LELIE, PN ;
HAN, JH ;
JANSEN, PLM ;
HOUGHTON, M ;
REESINK, HW .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1992, 27 (03) :166-168
[4]   IMPACT OF SPECIMEN HANDLING AND STORAGE ON DETECTION OF HEPATITIS-C VIRUS-RNA [J].
BUSCH, MP ;
WILBER, JC ;
JOHNSON, P ;
TOBLER, L ;
EVANS, CS .
TRANSFUSION, 1992, 32 (05) :420-425
[5]  
CHAYAMA K, 1991, HEPATOLOGY, V13, P1040
[6]   GENETIC ORGANIZATION AND DIVERSITY OF THE HEPATITIS-C VIRUS [J].
CHOO, QL ;
RICHMAN, KH ;
HAN, JH ;
BERGER, K ;
LEE, C ;
DONG, C ;
GALLEGOS, C ;
COIT, D ;
MEDINASELBY, A ;
BARR, PJ ;
WEINER, AJ ;
BRADLEY, DW ;
KUO, G ;
HOUGHTON, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (06) :2451-2455
[7]   HEPATITIS-C VIRUS - THE MAJOR CAUSATIVE AGENT OF VIRAL NON-A, NON-B HEPATITIS [J].
CHOO, QL ;
WEINER, AJ ;
OVERBY, LR ;
KUO, G ;
HOUGHTON, M ;
BRADLEY, DW .
BRITISH MEDICAL BULLETIN, 1990, 46 (02) :423-441
[8]   ANALYSIS OF GENOMIC VARIABILITY OF HEPATITIS-C VIRUS [J].
CUYPERS, HTM ;
WINKEL, IN ;
VANDERPOEL, CL ;
REESINK, HW ;
LELIE, PN ;
HOUGHTON, M ;
WEINER, A .
JOURNAL OF HEPATOLOGY, 1991, 13 :S15-S19
[9]   A LONG-TERM STUDY OF HEPATITIS-C VIRUS-REPLICATION IN NON-A, NON-B HEPATITIS [J].
FARCI, P ;
ALTER, HJ ;
WONG, D ;
MILLER, RH ;
SHIH, JW ;
JETT, B ;
PURCELL, RH .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (02) :98-104
[10]   HCV CONFIRMATORY TESTING OF BLOOD-DONORS [J].
FOLLETT, EAC ;
DOW, BC ;
MCOMISH, F ;
YAP, PL ;
HUGHES, W ;
MITCHELL, R ;
SIMMONDS, P .
LANCET, 1991, 338 (8773) :1024-1024