Automatic Myotendinous Junction Identification in Ultrasound Images Based on Junction-Based Template Measurements

被引:0
|
作者
Zhou, Guang-Quan [1 ]
Hua, Shi-Hao [1 ]
He, Yikang [2 ]
Wang, Kai-Ni [1 ]
Zhou, Dandan [3 ]
Wang, Hongxing [2 ]
Wang, Ruoli [4 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, Nanjing 210096, Peoples R China
[2] Southeast Univ, Zhongda Hosp, Dept Rehabil Med, Nanjing 210096, Peoples R China
[3] Nanjing Univ Chinese Med, Affiliated Hosp Integrated Tradit Chinese & Wester, Dept Crit Care Med, Nanjing 210028, Peoples R China
[4] Royal Inst Technol, Dept Engn Mech, KTH MoveAbil Lab, S-10044 Stockholm, Sweden
关键词
Ultrasonic imaging; Junctions; Tendons; Muscles; Ultrasonic variables measurement; Speckle; Phase measurement; Myotendinous junction detection; ultrasound; hierarchical clustering; Hessian matrix; phase congruency; Gaussian templates;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tracking the myotendinous junction (MTJ) motion in consecutive ultrasound images is essential to assess muscle and tendon interaction and understand the mechanics' muscle-tendon unit and its pathological conditions during motion. However, the inherent speckle noises and ambiguous boundaries deter the reliable identification of MTJ, thus restricting their usage in human motion analysis. This study advances a fully automatic displacement measurement method for MTJ using prior shape knowledge on the Y-shape MTJ, precluding the influence of irregular and complicated hyperechoic structures in muscular ultrasound images. Our proposed method first adopts the junction candidate points using a combined measure of Hessian matrix and phase congruency, followed by a hierarchical clustering technique to refine the candidates approximating the position of the MTJ. Then, based on the prior knowledge of Y-shape MTJ, we finally identify the best matching junction points according to intensity distributions and directions of their branches using multiscale Gaussian templates and a Kalman filter. We evaluated our proposed method using the ultrasound scans of the gastrocnemius from 8 young, healthy volunteers. Our results present more consistent with the manual method in the MTJ tracking method than existing optical flow tracking methods, suggesting its potential in facilitating muscle and tendon function examinations with in vivo ultrasound imaging.
引用
收藏
页码:851 / 862
页数:12
相关论文
共 50 条
  • [21] Model-based visualization of ultrasound images
    Kogan, RG
    Desai, M
    Pien, H
    Grimson, E
    BATTLEFIELD BIOMEDICAL TECHNOLOGIES, 1999, 3712 : 84 - 92
  • [22] Wavelet based denoising techniques for ultrasound images
    Duskunovic, I
    Pizurica, A
    Stippel, G
    Philips, W
    Lemahieu, I
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2662 - 2665
  • [23] Semi-automatic methods for tracking the medial gastrocnemius muscle-tendon junction using ultrasound: a validation study
    Cenni, Francesco
    Bar-On, Lynn
    Monari, Davide
    Schless, Simon-Henri
    Kalkman, Barbara M.
    Aertbelien, Erwin
    Desloovere, Kaat
    Bruyninckx, Herman
    EXPERIMENTAL PHYSIOLOGY, 2020, 105 (01) : 120 - 131
  • [24] COMPUTER-AIDED DIAGNOSIS BASED ON SPECKLE PATTERNS IN ULTRASOUND IMAGES
    Moon, Woo Kyung
    Lo, Chung-Ming
    Huang, Chiun-Sheng
    Chen, Jeon-Hor
    Chang, Ruey-Feng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (07): : 1251 - 1261
  • [25] Junction Engineering-Based Modeling and Optimization of Deep Junction Silicon Single-Photon Avalanche Diodes for Device Scaling
    Lee, Haewon
    Choi, Hyejeong
    Yun, Ilgu
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2022, 69 (09) : 4970 - 4975
  • [26] Synthesizing Real-Time Ultrasound Images of Muscle Based on Biomechanical Simulation and Conditional Diffusion Network
    Song, Zhen
    Zhou, Yihao
    Wang, Jianfa
    Ma, Christina Zong-Hao
    Zheng, Yongping
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (11) : 1501 - 1513
  • [27] Design of the Clockless Logic Gates Based on Quantum Phase Slip Junction
    Malekpoor, Azam
    Hashemi, Seyed Amir
    Jit, Satyabrata
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (06)
  • [28] Markov Chain Signal Generation Based on Single Magnetic Tunnel Junction
    Yuan, Xihui
    Jian, Jiajia
    Chai, Zheng
    An, Suihuan
    Gao, Yawei
    Zhou, Xue
    Zhang, Jian Fu
    Zhang, Weidong
    Min, Tai
    IEEE ELECTRON DEVICE LETTERS, 2023, 44 (12) : 1963 - 1966
  • [29] Automatic Force-Based Probe Positioning for Precise Robotic Ultrasound Acquisition
    Jiang, Zhongliang
    Grimm, Matthias
    Zhou, Mingchuan
    Hu, Ying
    Esteban, Javier
    Navab, Nassir
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (11) : 11200 - 11211
  • [30] Fully automatic and segmentation-robust classification of breast tumors based on local texture analysis of ultrasound images
    Liu, Bo
    Cheng, H. D.
    Huang, Jianhua
    Tian, Jiawei
    Tang, Xianglong
    Liu, Jiafeng
    PATTERN RECOGNITION, 2010, 43 (01) : 280 - 298