A TECHNIQUE FOR MEASURING THE THERMAL-CONDUCTIVITY AND EVALUATING THE APPARENT CONDUCTIVITY CONCEPT IN BIOMATERIALS

被引:8
作者
ARKIN, H
HOLMES, KR
CHEN, MM
机构
[1] TECHNION ISRAEL INST TECHNOL, DEPT VET BIOSCI, IL-32000 HAIFA, ISRAEL
[2] TECHNION ISRAEL INST TECHNOL, DEPT AGR ENGN, IL-32000 HAIFA, ISRAEL
[3] UNIV ILLINOIS, FAC BIOENGN, DEPT VET BIOSCI, URBANA, IL 61801 USA
[4] UNIV ILLINOIS, FAC BIOENGN, DEPT MECH & IND ENGN, URBANA, IL 61801 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1989年 / 111卷 / 04期
关键词
D O I
10.1115/1.3168379
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A simple technique for measuring thermal conductivity of biomaterials is described. The method is based on depositing a pulse of heat into the material of choice, and fitting the subsequent local temperature decay to that predicted by a theoretical model. This transient method is most suitable in situations where frequent measurements of the thermal conductivity are desired. The method was evaluated by calculating the thermal conductivity of several inert materials. The measured conductivities compared well with published values. The developed technique was also used to examine the applicability of the "apparent conductivity" index to combine both conductive and blood-convective thermal effects in living, blood perfused tissues. Using both simulated and experimental results, it was shown that the changes in the apparent conductivity are highly correlated with changes in blood flow. However, quantitative application of this index must be restricted to conditions that are similar to those which existed at the time the apparent conductivity was measured.
引用
收藏
页码:276 / 282
页数:7
相关论文
共 17 条
  • [1] A SENSITIVITY ANALYSIS OF THE THERMAL PULSE DECAY METHOD FOR MEASUREMENT OF LOCAL TISSUE CONDUCTIVITY AND BLOOD PERFUSION
    ARKIN, H
    HOLMES, KR
    CHEN, MM
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (01): : 54 - 58
  • [2] COMPUTER-BASED SYSTEM FOR CONTINUOUS ONLINE MEASUREMENTS OF TISSUE BLOOD PERFUSION
    ARKIN, H
    HOLMES, KR
    CHEN, MM
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (01): : 38 - 45
  • [3] THERMAL PULSE DECAY METHOD FOR SIMULTANEOUS MEASUREMENT OF LOCAL THERMAL-CONDUCTIVITY AND BLOOD PERFUSION - A THEORETICAL-ANALYSIS
    ARKIN, H
    HOLMES, KR
    CHEN, MM
    BOTTJE, WG
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (03): : 208 - 214
  • [4] THEORY, MEASUREMENT, AND APPLICATION OF THERMAL PROPERTIES OF BIOMATERIALS
    BOWMAN, HF
    CRAVALHO, EG
    WOODS, M
    [J]. ANNUAL REVIEW OF BIOPHYSICS AND BIOENGINEERING, 1975, 4 : 43 - 80
  • [5] CARSLAW HS, 1959, CONDUCTION HEAT SOLI, pCH10
  • [6] PULSE-DECAY METHOD FOR MEASURING THE THERMAL-CONDUCTIVITY OF LIVING TISSUES
    CHEN, MM
    HOLMES, KR
    RUPINSKAS, V
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (04): : 253 - 260
  • [7] CURTIS SE, 1983, ENV MANAGEMENT ANIMA, pCH4
  • [8] GATES DM, 1970, PHYSL BEHAVIORAL TEM, P177
  • [9] THERMAL-CONDUCTIVITY AND H2O CONTENT IN RABBIT KIDNEY CORTEX AND MEDULLA
    HOLMES, KR
    RYAN, W
    CHEN, MM
    [J]. JOURNAL OF THERMAL BIOLOGY, 1983, 8 (04) : 311 - 313
  • [10] HOLMES KR, 1984, 1984 ADV BIOENG ASME, P5