THE BIOMECHANICS OF THE HUMAN PATELLA DURING PASSIVE KNEE FLEXION

被引:147
作者
HEEGAARD, J
LEYVRAZ, PF
CURNIER, A
RAKOTOMANANA, L
HUISKES, R
机构
[1] HOP ORTHOPED SUISSE ROMANDE,LAUSANNE,SWITZERLAND
[2] ECOLE POLYTECH FED LAUSANNE,LMA,DME,LAUSANNE,SWITZERLAND
[3] UNIV NIJMEGEN,INST ORTHOPAED,NIJMEGEN,NETHERLANDS
[4] ECOLE POLYTECH FED LAUSANNE,LGM,DP,LAUSANNE,SWITZERLAND
关键词
PATELLA; KNEE; KINEMATICS; STRESS; LARGE SLIP CONTACT;
D O I
10.1016/0021-9290(95)00059-Q
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The fundamental objectives of patello-femoral joint biomechanics include the determination of its kinematics and of its' dynamics, as a function of given control parameters like knee flexion or applied muscle forces. On the one hand, patellar tracking provides quantitative information about the joint's stability under given loading conditions, whereas patellar force analyses can typically indicate pathological stress distributions associated for instance with abnormal tracking. The determination of this information becomes especially relevant when facing the problem of evaluating surgical procedures in terms of standard (i.e. non-pathological) knee functionality. Classical examples of such procedures include total knee replacement (TKR) and elevation of the tibial tubercle (Maquet's procedure). Following this perspective, the current study was oriented toward an accurate and reliable determination of the human patella biomechanics during passive knee flexion. To this end, a comprehensive three-dimensional computer model, based on the finite element method, was developed for analyzing articular biomechanics. Unlike previously published studies on patello-femoral biomechanics, this model simultaneously computed the joint's kinematics, associated tendinous and ligamentous forces, articular contact pressures and stresses occurring in the joint during its motion. The components constituting the joint (i.e. bone, cartilage, tendons) were modeled using objective forms of non-linear elastic materials laws. A unilateral contact law allowing for large slip between the patella and the femur was implemented using an augmented Lagrangian formulation. Patellar kinematics computed for two knee specimens were close to equivalent experimental ones (average deviations below 0.5 degrees for the rotations and below 0.5 mm for the translations) and provided validation of the model on a specimen by specimen basis. The ratio between the quadriceps pulling force and the patellar tendon force was less than unity throughout the considered knee flexion range (30-150 degrees), with a minimum near 90 degrees of flexion for both specimens. The contact patterns evolved from the distal part of the retropatellar articular surface to the proximal pole during progressive flexion. The lateral facet bore more pressure than the medial one, with corresponding higher stresses (hydrostatic) in the lateral compartment of the patella. The forces acting on the patella were part of the problem unknowns, thus leading to more realistic loadings for the stress analysis, which was especially important when considering the wide range of variations of the contact pressure acting on the patella during knee flexion.
引用
收藏
页码:1265 / 1279
页数:15
相关论文
共 79 条
[1]   FORCE ANALYSIS OF THE PATELLAR MECHANISM [J].
AHMED, AM ;
BURKE, DL ;
HYDER, A .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (01) :69-85
[2]   INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .2. RETROPATELLAR SURFACE [J].
AHMED, AM ;
BURKE, DL ;
YU, A .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :226-234
[3]  
AHMED AM, 1989, 35TH P ANN M ORS, P202
[4]  
ALART P, 1991, COMPUT METHODS APPL, V9, P353
[5]   MODEL STUDIES OF THE STIFFNESS CHARACTERISTICS OF THE HUMAN KNEE-JOINT [J].
ANDRIACCHI, TP ;
MIKOSZ, RP ;
HAMPTON, SJ ;
GALANTE, JO .
JOURNAL OF BIOMECHANICS, 1983, 16 (01) :23-29
[6]  
[Anonymous], 1981, INTRO CONTINUUM MECH
[7]  
BANDI W, 1970, HELV CHIR ACTA S, V11, P1
[8]   LIGAMENT-BONE INTERACTION IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
HUISKES, R .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (03) :263-269
[9]  
BONNEL F, 1988, LAPPAREIL EXTENSEUR
[10]   PATELLAR TRACKING PATTERNS DURING ACTIVE AND PASSIVE KNEE EXTENSION - EVALUATION WITH MOTION-TRIGGERED CINE MR IMAGING [J].
BROSSMANN, J ;
MUHLE, C ;
SCHRODER, C ;
MELCHERT, UH ;
BULL, CC ;
SPIELMANN, RP ;
HELLER, M .
RADIOLOGY, 1993, 187 (01) :205-212