SECONDARY CERVICAL PERFORATION BY THE COPPER-T INTRA-UTERINE DEVICE

被引:4
作者
OVADIA, J
REICHMAN, J
GOLDMAN, JA
机构
[1] TEL AVIV UNIV, HASHARON HOSP, TEL AVIV, ISRAEL
[2] TEL AVIV UNIV, SACKLER SCH MED, RAMAT AVIV, ISRAEL
关键词
cervical perforation; intrauterine device;
D O I
10.1016/0028-2243(79)90135-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Cases [5] of cervical perforation were observed in women with a Copper-T intrauterine contraceptive device, over a period of 5 yr. In all cases, the distal end of the stem (vertical limb) of the T had perforated through the cervical wall into 1 of the vaginal fornices. Only 2 cases had symptoms leading to the discovery of the device, while the other 3 were discovered accidentally or on routine examination.
引用
收藏
页码:403 / 404
页数:2
相关论文
共 5 条
[1]   PERFORATION OF UTERUS BY COPPER-T AND COPPER-7 INTRAUTERINE CONTRACEPTIVE DEVICES [J].
CEDERQVIST, LL ;
LINDHE, BA ;
FUCHS, F .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1975, 54 (02) :183-189
[2]   CERVICAL PERFORATION BY COPPER-T INTRAUTERINE CONTRACEPTIVE DEVICE [J].
CEDERQVIST, LL ;
FUCHS, F .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1974, 119 (06) :854-855
[3]  
PAULSON JD, 1977, OBSTET GYNECOL, V50, P621
[4]   CERVICAL PERFORATION BY COPPER-T INTRAUTERINE DEVICE [J].
RIENPRAYURA, D ;
PHAOSAVASDI, S ;
SOMBOONSUK, A .
CONTRACEPTION, 1973, 7 (06) :515-521
[5]  
Schifrin B S, 1969, J Fla Med Assoc, V56, P184