Hearing threshold for pure tones above 20 kHz

被引:35
|
作者
Ashihara, Kaoru [1 ]
Kurakata, Kenji [1 ]
Mizunami, Tazu [1 ]
Matsushita, Kazuma [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, AIST Tsukuba Cent 6, Tsukuba, Ibaraki 3058566, Japan
[2] Natl Inst Technol & Evaluat, Tsukuba, Ibaraki 3050044, Japan
关键词
Threshold of hearing; Masked threshold; Subharmonic distortion; Ultrasound;
D O I
10.1250/ast.27.12
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Hearing thresholds for pure tones from 2 kHz to 28 kHz were measured. A 2AFC procedure combined with a 3-down 1-up transformed up-down method was employed to obtain threshold values that were less affected by listener's criterion of judgment. From some listeners, threshold values of 88 dB SPL or higher were obtained for a tone at 24 kHz, whereas thresholds could not be obtained from all participants at 26 kHz and above. Furthermore, thresholds were also measured under masking by a noise low-pass filtered at 20 kHz. At frequencies above 20 kHz, the difference of threshold values between with and without the masking noise was a few decibels, indicating that the tone detection was not affected by subharmonic components that might have appeared in the lower frequency regions. The results of measurement also showed that the threshold increased rather gradually for tones from 20 to 24 kHz whereas it increased sharply from 14 to 20 kHz.
引用
收藏
页码:12 / 19
页数:8
相关论文
共 36 条
  • [1] Threshold of hearing in free field for high-frequency tones from 1 to 20 kHz
    Kurakata, Kenji
    Ashihara, Kaoru
    Matsushita, Kazuma
    Tamai, Hideki
    Ihara, Yoshiyuki
    Kurakata, K. (kurakata-k@aist.go.jp), 1600, Acoustical Society of Japan (24): : 398 - 399
  • [2] Laser thermoelastic generation in metals above the melt threshold
    Every, A. G.
    Utegulov, Z. N.
    Veres, I. A.
    JOURNAL OF APPLIED PHYSICS, 2013, 114 (20)
  • [3] Effects of pulsed ultrasound at 20 kHz on the sonochemical degradation of mycotoxins
    Liu, Y.
    Li, M.
    Bai, F.
    Bian, K.
    WORLD MYCOTOXIN JOURNAL, 2019, 12 (04) : 357 - 366
  • [4] Ocular drug delivery using 20-kHz ultrasound
    Zderic, V
    Vaezy, S
    Martin, RW
    Clark, JI
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (06) : 823 - 829
  • [5] Disinfection of wastewater using a 20-kHz ultrasound unit
    Madge, BA
    Jensen, JN
    WATER ENVIRONMENT RESEARCH, 2002, 74 (02) : 159 - 169
  • [6] Neuroethology of the katydid T-cell I. Tuning and responses to pure tones
    Faure, PA
    Hoy, RR
    JOURNAL OF EXPERIMENTAL BIOLOGY, 2000, 203 (21) : 3225 - 3242
  • [7] Above-threshold dynamics of acoustic domains in liquid crystals
    Kapustina, O. A.
    JETP LETTERS, 2014, 100 (04) : 232 - 236
  • [8] Above-threshold dynamics of acoustic domains in liquid crystals
    O. A. Kapustina
    JETP Letters, 2014, 100 : 232 - 236
  • [9] Sonoelectrochemical (20 kHz) production of platinum nanoparticles from aqueous solutions
    Zin, Valentina
    Pollet, Bruno G.
    Dabala, Manuele
    ELECTROCHIMICA ACTA, 2009, 54 (28) : 7201 - 7206
  • [10] Flow effects on sonochemical oxidation activity in a 20 kHz ultrasonic horn system
    Fattahi, Kobra
    Dodier, Gabriel
    Robert, Etienne
    Boffito, Daria C.
    CHEMICAL ENGINEERING JOURNAL, 2024, 489