CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP

被引:1040
作者
HARRISON, DJ [1 ]
MANZ, A [1 ]
FAN, ZH [1 ]
LUDI, H [1 ]
WIDMER, HM [1 ]
机构
[1] CIBA GEIGY AG,FORSCH ANALYT,CH-4002 BASEL,SWITZERLAND
关键词
D O I
10.1021/ac00041a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of miniaturizing a chemical analysis system on a planar substrate has been demonstrated for a system utilizing electrokinetic phenomena for sample separation and solvent pumping. Using micromachining techniques, a complex manifold of capillary channels has been fabricated in a planar glass substrate and the separation of a mixture of fluorescein and caicein within the channels was achieved using electrophoresis. The maximum number of theoretical plates obtained was about 35 000 for caicein, with 5000 V applied, corresponding to 2100 V between the injection and fluorescence detection points in the channels. The number of theoretical plates observed was in agreement with theory, indicating no interactions between the analyte and the glass walls. The electroosmotic flow rate in the glass channels was (4.5 +/- 0.1) X 10(-4) cm2/(V.s) using a pH 8.5 50 mM boric acid, 50 mM Tris buffer, comparable to (5.87 +/- 0.08) X 10(-4) cm2/(V.s) measured in fused-silica capillaries. Solvent flow could be directed along a specified capillary by application of appropriate voltages, so that valveless switching of fluid flow between capillaries could be achieved. These results provide a foundation for the design of more complex sample treatment and separation systems Integrated on glass or silicon substrates.
引用
收藏
页码:1926 / 1932
页数:7
相关论文
共 31 条
  • [1] SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE
    CHENG, YF
    DOVICHI, NJ
    [J]. SCIENCE, 1988, 242 (4878) : 562 - 564
  • [2] DELAHAY P, 1948, B SOC CHIM FR, V15, P348
  • [3] NORMALLY CLOSED MICROVALVE AND MICROPUMP FABRICATED ON A SILICON-WAFER
    ESASHI, M
    SHOJI, S
    NAKANO, A
    [J]. SENSORS AND ACTUATORS, 1989, 20 (1-2): : 163 - 169
  • [4] CAPILLARY ELECTROPHORESIS
    EWING, AG
    WALLINGFORD, RA
    OLEFIROWICZ, TM
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (04) : A292 - +
  • [5] INTEGRATED MOVABLE MICROMECHANICAL STRUCTURES FOR SENSORS AND ACTUATORS
    FAN, LS
    TAI, YC
    MULLER, RS
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1988, 35 (06) : 724 - 730
  • [6] GALE RJ, 1990, BIOSENSOR TECHNOLOGY, P55
  • [7] A FLOW-INJECTION ANALYSIS SYSTEM FOR FERMENTATION MONITORING AND CONTROL
    GARN, M
    GISIN, M
    THOMMEN, C
    CEVEY, P
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) : 423 - 428
  • [8] INDUSTRIAL-PROCESS CONTROL BY FLOW-INJECTION ANALYSIS
    GISIN, M
    THOMMEN, C
    [J]. ANALYTICA CHIMICA ACTA, 1986, 190 (01) : 165 - 176
  • [9] THE USE OF CHEMICAL SENSORS IN INDUSTRY
    GRABER, N
    LUDI, H
    WIDMER, HM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 239 - 243
  • [10] ANALYSIS OF FACTORS CAUSING PEAK BROADENING IN CAPILLARY ZONE ELECTROPHORESIS
    HUANG, XH
    COLEMAN, WF
    ZARE, RN
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 95 - 110