Sniff-testing for indoor air contaminants from new buildings environment detecting by aspiration-type ion mobility spectrometry

被引:16
作者
Arnanthigo, Yonsuang [1 ]
Anttalainen, Osmo [2 ]
Safaei, Zahra [1 ]
Sillanpaa, Mika [1 ]
机构
[1] Lappeenranta Univ Technol, Sch Technol, Lab Green Chem, Sammonkatu 12, FI-50130 Mikkeli, Finland
[2] Environics Oy, Sammonkatu 12, FI-50130 Mikkeli, Finland
关键词
Ion mobility spectrometry; IMS; Indoor air pollution; Indoor air detection; Indoor air quality; Sniff test; Indoor air quality sensing;
D O I
10.1007/s12127-016-0189-0
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
New construction materials, building and car interiors, and furnishings typically cause air pollution by means of emitting toxic chemical substances indoors. The level of health hazard to the occupants depends on the emission rate of the pollutants, the period of occupant exposure to the pollutants and the concentration of the emitted toxic substances. Typical health effects induced by the indoor air contaminants include symptoms such as dizziness, light-headedness, concentration trouble, nausea, epistaxis, eyes, nose and throat irritation, dryness of nose and throat, and decreased mucous flow rate. Traditional offline indoor air detection techniques, namely, mass spectrometry (MS), gas chromatography (GC) and UV spectroscopy involve collection of indoor air samples from the field followed by laboratory analysis. Because these techniques are slow and time consuming, online indoor air detection and monitoring techniques which are fast, reliable and accurate enough to trigger more extensive analysis are required. In this paper, ion mobility spectrometry for an alternative indoor air detection technique is studied. An aspiration-type ion mobility spectrometer (IMS), in the form of a portable and handheld unit, is employed for the online detection of indoor air contaminants. By means of sniff tests performed on the 62 most commonly occurring indoor air contaminants, the sensitivity of aspiration-type IMS technique towards the indoor air contaminants and hence its suitability for indoor air quality detection is evaluated and demonstrated.
引用
收藏
页码:15 / 30
页数:16
相关论文
共 42 条
[21]   Enhancing capabilities of aspiration-type Ion Mobility Spectrometer using a Pulsed Sampling System and a heated transfer line [J].
Mikedi, K. ;
Pallis, G. C. ;
Koumoundouros, G. C. ;
Vamvakari, J. ;
Statheropoulos, G. ;
Psarras, G. ;
Moll, V. H. ;
McEntee, R. ;
Statheropoulos, M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 :240-248
[22]   A novel micromachined high-field asymmetric waveform-ion mobility spectrometer [J].
Miller, RA ;
Eiceman, GA ;
Nazarov, EG ;
King, AT .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (03) :300-306
[23]   Methodology for assessing human health impacts due to pollutants emitted from building materials [J].
Park, Hyo Seon ;
Ji, Changyoon ;
Hong, Taehoon .
BUILDING AND ENVIRONMENT, 2016, 95 :133-144
[24]   Ion mobility spectrometers with doped gases [J].
Puton, Jaroslaw ;
Nousiainen, Marjaana ;
Sillanpaa, Mika .
TALANTA, 2008, 76 (05) :978-987
[25]   Determination of seven pyrethroids biocides and their synergist in indoor air by thermal-desorption gas chromatography/mass spectrometry after sampling on Tenax TA® passive tubes [J].
Raeppel, Caroline ;
Appenzeller, Brice M. ;
Millet, Maurice .
TALANTA, 2015, 131 :309-314
[26]   Physicochemical characterisation of odours [J].
Ramel, M ;
Nomine, M .
ANALUSIS, 2000, 28 (03) :171-179
[27]   Differentiation of air samples with and without microbial volatile organic compounds by aspiration ion mobility spectrometry and semiconductor sensors [J].
Rasanen, Riikka-Marjaana ;
Hakansson, Markus ;
Viljanen, Martti .
BUILDING AND ENVIRONMENT, 2010, 45 (10) :2184-2191
[28]   Cooling load reduction in office buildings of hot-arid climate, combining phase change materials and night purge ventilation [J].
Solgi, Ebrahim ;
Fayaz, Rima ;
Kari, Behrouz Mohammad .
RENEWABLE ENERGY, 2016, 85 :725-731
[29]  
Sun Y., 2005, DETECTION TECHNOLOGI
[30]   Detection of microbial volatile organic compounds (MVOCs) by ion-mobility spectrometry [J].
Tiebe, Carlo ;
Miessner, Hans ;
Koch, Bernhard ;
Huebert, Thomas .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (07) :2313-2323