A SYSTEM FOR CEREBRAL BLOOD-FLOW MEASUREMENT USING AN (H2O)-O-15 AUTORADIOGRAPHIC METHOD AND POSITRON EMISSION TOMOGRAPHY

被引:171
作者
KANNO, I
IIDA, H
MIURA, S
MURAKAMI, M
TAKAHASHI, K
SASAKI, H
INUGAMI, A
SHISHIDO, F
UEMURA, K
机构
关键词
D O I
10.1038/jcbfm.1987.37
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:143 / 153
页数:11
相关论文
共 21 条
[1]   STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY [J].
ALPERT, NM ;
ERIKSSON, L ;
CHANG, JY ;
BERGSTROM, M ;
LITTON, JE ;
CORREIA, JA ;
BOHM, C ;
ACKERMAN, RH ;
TAVERAS, JM .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) :28-34
[2]   A NONINVASIVE APPROACH TO QUANTITATIVE FUNCTIONAL BRAIN MAPPING WITH H-20-15 AND POSITRON EMISSION TOMOGRAPHY [J].
FOX, PT ;
MINTUN, MA ;
RAICHLE, ME ;
HERSCOVITCH, P .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (03) :329-333
[3]   QUANTITATIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN-METABOLISM IN MAN USING O-15 AND POSITRON EMISSION TOMOGRAPHY - THEORY, PROCEDURE, AND NORMAL VALUES [J].
FRACKOWIAK, RSJ ;
LENZI, GL ;
JONES, T ;
HEATHER, JD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) :727-736
[4]  
GINSBERG MD, 1984, ANN NEUROL, V15, pS12
[5]  
HAGAMI E, 1986, JPN J NUCL MED, V23, P351
[6]   EFFECT OF TISSUE HETEROGENEITY ON THE MEASUREMENT OF CEREBRAL BLOOD-FLOW WITH THE EQUILIBRIUM (CO2)-O-15 INHALATION TECHNIQUE [J].
HERSCOVITCH, P ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (04) :407-415
[7]   WHAT IS THE CORRECT VALUE FOR THE BRAIN BLOOD PARTITION-COEFFICIENT FOR WATER [J].
HERSCOVITCH, P ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1985, 5 (01) :65-69
[8]   QUANTITATIVE MEASUREMENT OF LOCAL CEREBRAL BLOOD-FLOW IN HUMANS BY POSITRON COMPUTED-TOMOGRAPHY AND O-15-WATER [J].
HUANG, SC ;
CARSON, RE ;
HOFFMAN, EJ ;
CARSON, J ;
MACDONALD, N ;
BARRIO, JR ;
PHELPS, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (02) :141-153
[9]   ERROR ANALYSIS OF A QUANTITATIVE CEREBRAL BLOOD-FLOW MEASUREMENT USING (H2O)-O-15 AUTORADIOGRAPHY AND POSITRON EMISSION TOMOGRAPHY, WITH RESPECT TO THE DISPERSION OF THE INPUT FUNCTION [J].
IIDA, H ;
KANNO, I ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
UEMURA, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (05) :536-545
[10]   ERROR ANALYSIS FOR THE DETERMINATION OF CEREBRAL BLOOD-FLOW WITH THE CONTINUOUS INHALATION OF O-15-LABELED CARBON-DIOXIDE AND POSITRON EMISSION TOMOGRAPHY [J].
JONES, SC ;
GREENBERG, JH ;
REIVICH, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (01) :116-124