Ultrasound-guided infraclavicular axillary vein cannulation

被引:2
作者
Garcia-Diaz, M. A. [1 ]
Ruiz-Castro, M. [1 ]
Barrios, F. [1 ]
Ayuso-Antolinos, M. [1 ]
机构
[1] Hosp Univ Principe Asturias, Serv Anestesiol, Madrid, Spain
来源
REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION | 2012年 / 59卷 / 05期
关键词
Ultrasound-guided; Ultrasounds; Central venous; cannulation; catheter; Axillary vein;
D O I
10.1016/j.redar.2012.03.022
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: Percutaneous central venous cannulation is a challenging procedure. Traditionally, an external landmark technique has been used to identify puncture site. We wanted to evaluate an ultrasound-guided technique for the axillary vein cannulation, looking specifically at the ease of use, success rate and decreased complications. Methods: Sixty consecutive surgical patients scheduled for central venous catheter placement were registered. An ultrasound scanner made for guiding an in plane puncture of axillary vein was used. After locating the vessels, an echo-guided sterile procedure was performed to cannulate the vein. Results: Cannulation was successful in all patients, and there were no complications during insertion of the catheters. Both axillary veins were cannulated, and the vein was punctured successfully at first attempt in 95% of the patients. The median time from the start of the first puncture (of the skin) until the aspiration of blood was 15 (7- 135) seconds. Conclusion: This ultrasound-guided technique for inserting central venous catheters in axillary vein was easy to apply. This procedure could increase precision and safety in patients undergoing axillary vein cannulation. (C) 2011 Sociedad Espanola de Anestesiologia, Reanimacion y Terapeutica del Dolor. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:254 / 258
页数:5
相关论文
共 14 条
[1]  
Barash P., 2009, MED REP, V1, P65
[2]   Ultrasonic locating devices for central venous cannulation: meta-analysis [J].
Hind, D ;
Calvert, N ;
McWilliams, R ;
Davidson, A ;
Paisley, S ;
Beverley, C ;
Thomas, S .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7411) :361-364
[3]   Before we go too far: Ultrasound-guided central catheter placement [J].
Levitov, Alexander B. ;
Aziz, Sameh ;
Slonim, Anthony D. .
CRITICAL CARE MEDICINE, 2009, 37 (08) :2473-2474
[4]   A novel technique for ultrasound-guided supraclavicular subclavian cannulation [J].
Mallin, Michael ;
Louis, Hunter ;
Madsen, Troy .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (08) :966-969
[5]  
Maslove D, 2010, NEW ENGL J MED, V363, P796, DOI 10.1056/NEJMc1006062
[6]   Current concepts - Preventing complications of central venous catheterization [J].
McGee, DC ;
Gould, MK .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (12) :1123-1133
[7]   Ultrasound-guided puncture of the jugular vein using a posterior approach [J].
Perez Reyes, J. M. ;
Bethencourt Munoz, S. ;
Cabrejas Ibarz, M. T. ;
Tejero Garcia, M. ;
Valdivia Martin, J. ;
Gonzalez Miranda, F. .
REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2008, 55 (10) :616-620
[8]   Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature [J].
Randolph, AG ;
Cook, DJ ;
Gonzales, CA ;
Pribble, CG .
CRITICAL CARE MEDICINE, 1996, 24 (12) :2053-2058
[9]   Transpectoral ultrasound-guided catheterization of the axillary vein: An alternative to standard catheterization of the subclavian vein [J].
Sandhu, NS .
ANESTHESIA AND ANALGESIA, 2004, 99 (01) :183-187
[10]   Ultrasound-guided infraclavicular axillary vein cannulation for central venous access [J].
Sharma, A ;
Bodenham, AR ;
Mallick, A .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 93 (02) :188-192