THE EFFECTS OF REPROCESSING CUPROPHANE AND POLYSULFONE DIALYZERS ON BETA-2-MICROGLOBULIN REMOVAL FROM HEMODIALYSIS-PATIENTS

被引:26
|
作者
PETERSEN, J
MOORE, RM
KACZMAREK, RG
SINGH, B
YEH, I
HAMBURGER, S
KANKAM, M
机构
[1] US FDA,CTR DEVICES & RADIOL HLTH,OFF SCI & TECHNOL,DIV BIOMETR SCI,EPIDEMIOL BRANCH,ROCKVILLE,MD 20852
[2] STANFORD UNIV,VET ADM MED CTR,SCH MED,DEPT NEPHROL,PALO ALTO,CA 94304
关键词
HEMODIALYSIS; DIALYZER REUSE; BETA-2-MICROGLOBULIN;
D O I
10.1016/S0272-6386(12)81125-5
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
To further define the relationship between dialyzer reuse and the removal of β2-microglobulin (β2M) during dialysis, 26 patients who received hemodialysis were studied. Thirteen patients were dialyzed with conventional cuprophane dialyzers, and thirteen patients were dialyzed with high-flux polysulfone dialyzers. Patients in each group were dialyzed with only new dialyzers during the primary-use phase of the study, and reprocessed dialyzers during the reuse phase. Dialyzers were used six times during the reuse phase. Serum β2M levels were measured both predialysis and postdialysis, and adjusted for fluid loss. Dialysis with conventional cuprophane new dialyzers during the primary-use phase of the study resulted in a 3.3% increase in serum β2M levels, and a 2.4% increase in serum β2M levels during the reuse phase. The difference in the change of the concentration of β2M between primary-use and reuse phases was not statistically significant. Dialysis with high-flux polysulfone new dialyzers during the primary-use phase was associated with a decrease of 59.5% in the mean postdialysis concentration of serum β2M compared with the predialysis level. A corresponding decrease of 62.6% in serum β2M levels was observed after dialysis with high-flux polysulfone reprocessed dialyzers during the reuse phase. These data show no evidence of an adverse effect on the clearance of β2M during dialysis from the reuse of dialyzers up to six times. The results confirm previous studies that have reported that high-flux dialysis with polysulfone dialyzers removes substantial amounts of β2M, and dialysis with conventional cuprophane dialyzers does not. © 1991, National Kidney Foundation, Inc.. All rights reserved.
引用
收藏
页码:174 / 178
页数:5
相关论文
共 50 条
  • [1] THE EFFECTS OF REPROCESSING HIGH-FLUX POLYSULFONE DIALYZERS WITH PEROXYACETIC ACID ON BETA-2-MICROGLOBULIN REMOVAL IN HEMODIAFILTRATION
    KERR, PG
    ARGILES, A
    CANAUD, B
    FLAVIER, JL
    MION, C
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1992, 19 (05) : 433 - 438
  • [2] EFFECT OF DIALYZER REPROCESSING WITH RENALIN ON SERUM BETA-2-MICROGLOBULIN AND COMPLEMENT ACTIVATION IN HEMODIALYSIS-PATIENTS
    WESTHUYZEN, J
    FOREMAN, K
    BATTISTUTTA, D
    SALTISSI, D
    FLEMING, SJ
    AMERICAN JOURNAL OF NEPHROLOGY, 1992, 12 (1-2) : 29 - 36
  • [3] BETA-2-MICROGLOBULIN GENERATION RATE AND CLEARANCE RATE IN MAINTENANCE HEMODIALYSIS-PATIENTS
    MAEDA, K
    SHINZATO, T
    OTA, T
    KOBAYAKAWA, H
    TAKAI, I
    FUJITA, Y
    MORITA, H
    NEPHRON, 1990, 56 (02): : 118 - 125
  • [4] BETA-2-MICROGLOBULIN GENERATION AND REMOVAL IN LONG SLOW AND SHORT FAST HEMODIALYSIS
    SKROEDER, NR
    JACOBSON, SH
    HOLMQUIST, B
    KJELLSTRAND, P
    KJELLSTRAND, CM
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (05) : 519 - 526
  • [5] THE EFFECT OF DIALYZER REPROCESSING ON PERFORMANCE AND BETA(2)-MICROGLOBULIN REMOVAL USING POLYSULFONE MEMBRANES
    DIAZ, RJ
    WASHBURN, S
    CAUBLE, L
    SISKIND, MS
    VANWYCK, D
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (04) : 405 - 410
  • [6] The removal of beta-2-microglobulin by an immunoadsorption wall
    Yang, TH
    Lee, CJ
    Chu, IM
    Hwang, JC
    Yang, TL
    ARTIFICIAL ORGANS, 1999, 23 (02) : 131 - 138
  • [7] THE ROLE OF ADSORPTION IN BETA-2-MICROGLOBULIN REMOVAL
    DAVID, S
    CANINO, F
    FERRARI, ME
    CAMBI, V
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1991, 6 : 64 - 68
  • [8] In Vitro Removal of Beta-2-Microglobulin From Uremic Blood With an Immunoadsorption Wall
    Yang, Tsung-Hua
    Lin, Bo-Jhou
    Ma, Yi-Ling
    Chou, Kang-Ju
    ARTIFICIAL ORGANS, 2012, 36 (01) : 78 - 86
  • [9] Membrane flux not biocompatibility determines beta-2-microglobulin levels in hemodialysis patients
    Pickett, TM
    Cruickshank, A
    Greenwood, RN
    Taube, D
    Davenport, A
    Farrington, K
    BLOOD PURIFICATION, 2002, 20 (02) : 161 - 166
  • [10] HIGH-FLUX SYNTHETIC VERSUS CELLULOSIC MEMBRANES FOR BETA-2-MICROGLOBULIN REMOVAL DURING HEMODIALYSIS, HEMODIAFILTRATION AND HEMOFILTRATION
    FLOEGE, J
    GRANOLLERAS, C
    DESCHODT, G
    HECK, M
    BAUDIN, G
    BRANGER, B
    TOURNIER, O
    REINHARD, B
    EISENBACH, GM
    SMEBY, LC
    KOCH, KM
    SHALDON, S
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1989, 4 (07) : 653 - 657