AN ATTEMPT TO PREPARE HEPATITIS-B VIRUS (HBV)-FREE PLASMA BY ULTRAFILTRATION USING MICROPOROUS REGENERATED CELLULOSE HOLLOW FIBER

被引:8
作者
SEKIGUCHI, S
ITO, K
KOBAYASHI, M
IKEDA, H
MANABE, S
TSURUMI, T
ISHIKAWA, G
SATANI, M
YAMAGUCHI, K
机构
[1] Hokkaido Red Cross Blood Center, Nishi-ku, Sapporo
[2] Asahi Chemical Industry Co. Ltd, Cniyodaku, Tokyo, Imperial Twr. 18F
[3] Institute of Laboratory Animals, Yamaguchi University School of Medicine, Ube, Yamaguchi
来源
TRANSFUSION SCIENCE | 1990年 / 11卷 / 02期
关键词
D O I
10.1016/0955-3886(90)90097-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Hepatitis B Virus(HBV) can be effectively removed from HBV-positive plasma by filtration with a Bemberg(R) Microporous Membrane (BMM) with a pore size of 30 nm or less, however considerable amounts of macromolecular IgM and Factor VIII are trapped in the BMM. We report that HBV-free plasma with adequate amounts of all of the plasma proteins can be obtained by double filtration with a BMM with a pore size of 50 nm. Thus, it may be possible to remove HBV or other transfusion-associated viruses from plasma by BMM filtration with good recovery of all of the plasma components.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 13 条
[1]  
Harada, Yoshiyama, Yamamoto, Effect of heat and fresh human serum on the infectivity of human T-cell lymphotropic virus type III evaluated with new bioassay systems, J Clin Microbiol, 22, pp. 908-911, (1985)
[2]  
Schimpf, Mannucci, Kreutz, Brackmann, Auerswald, Ciavar-ella, Mosseler, DeRosa, Kraus, Brueckmann, Mancuso, Mittler, Haschke, Morfini, Absence of hepatitis after treatment with a pasteurized factor VIII concentrate in patients with hemophilia and no previous transfusions, N Engl J Med, 316, pp. 918-922, (1987)
[3]  
Prince, Stephan, Brotman, Beta-propiolactone/ultraviolet irradiation: a review of its effectiveness for inactivation of viruses in blood derivatives, Rev Infect Dis, 5, pp. 92-107, (1983)
[4]  
Horowitz, Wiebe, Lippin, Stryker, Inactivation of viruses in labile blood derivatives I. Disruption of lipid-enveloped viruses by tri(n-butyl) phosphate, Transfusion, 25, pp. 516-522, (1985)
[5]  
Hamamoto, Harada, Kobayashi, Yamaguchi, Iijima, Manabe, Tsurumi, Aizawa, Yamamoto, A novel method for removal of human immunodeficiency virus (HIV): filtration with porous polymeric membrane, Vox Sang, 56, pp. 230-236, (1989)
[6]  
Kamide, Manabe, Role of microporous separation phenomena in the formation of porous polymeric membranes, Materials Science of Synthetic Membranes, pp. 197-228, (1985)
[7]  
Takahashi, Nakagawa, Hashimoto, Takahashi, Imai, Miyakawa, Mayumi, Large-scale isolation of Dane particles from plasma containing hepatitis B antigen and demonstration of a circular double-stranded DNA molecule extruding directly from their cores, J Immunol, 117, (1976)
[8]  
Hirata, Emerick, Boley, Hepatitis B virus antigen detection by reverse passive hemagglutination, Proc Soc Exp Biol Med, 143, pp. 761-763, (1973)
[9]  
Beminger, Hammer, Hoyer, Gerin, An assay for the detection of the dna genome of hepatitis b virus in serum, Journal of Medical Virology, 9, (1982)
[10]  
Hardisty, Macpherson, A one stage factor VIII (antihaemophilic globulin) assay and its use on venous and capillary plasma, Thromb Diath Haemorrh, 7, pp. 215-228, (1962)