METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS

被引:440
作者
AGINS, HJ
ALCOCK, NW
BANSAL, M
SALVATI, EA
WILSON, PD
PELLICCI, PM
BULLOUGH, PG
机构
[1] MEM SLOAN KETTERING CANC CTR, DEPT MED, NEW YORK, NY 10021 USA
[2] HOSP SPECIAL SURG, NEW YORK, NY 10021 USA
关键词
D O I
10.2106/00004623-198870030-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
引用
收藏
页码:347 / 356
页数:10
相关论文
共 41 条
[1]   TISSUE REACTION TO IMPLANTED BIOMATERIALS [J].
AKAGAWA, Y ;
HASHIMOTO, M ;
KONDO, N ;
YAMASAKI, A ;
TSURU, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (05) :681-686
[2]  
ALCOCK NW, UNPUB TISSUE ANAL TI
[3]  
BEDER OE, 1956, SURGERY, V39, P470
[4]  
Bothe RT., 1940, SURG GYNECOL OBSTET, V71, P598
[5]   RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[6]  
CANTLEY LC, 1978, J BIOL CHEM, V253, P7361
[7]  
CANTLEY LC, 1977, J BIOL CHEM, V252, P7421
[8]  
CLARKE IC, 1983, ASTM STP, V796, P136
[9]  
DOBBS HS, 1983, ASTM STP, V796, P173
[10]   INVIVO METAL-ION RELEASE FROM POROUS TITANIUM-FIBER MATERIAL [J].
DUCHEYNE, P ;
WILLEMS, G ;
MARTENS, M ;
HELSEN, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (03) :293-308