ELEMENTAL ANALYSIS OF RENAL SLICES BY PROTON-INDUCED X-RAY-EMISSION

被引:16
作者
LOWE, T
CHEN, Q
FERNANDO, Q
KEITH, R
GANDOLFI, AJ
机构
[1] UNIV ARIZONA,DEPT CHEM,TUCSON,AZ 85721
[2] UNIV ARIZONA,DEPT ANESTHESIOL,TUCSON,AZ 85724
关键词
ARSENIC; CADMIUM; CHROMIUM; ELEMENTAL ANALYSIS; INTERACTIVE TOXICITY; MERCURY; METAL ANALYSIS; NEPHROTOXICITY; PROTON-INDUCED X-RAY EMISSION (PIXE); X-RAY EMISSION;
D O I
10.2307/3431439
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We optimized proton-induced X-ray emission (PIXE) for tissue analysis in a toxicity-disposition study.We used cultured rabbit renal slices as the biological system to demonstrate the use of PIXE analysis. The renal slices were exposed to HgCl2+ CdCl2, K2Cr2O7, or NaAsO2 alone or in a mixture. The PIXE analysis provides information on concentrations of elements above atomic number 11, and it is the only analytical technique that can determine 20-30 elements nondestructively in a single, small sample (approximately 5 mg) with detection limits of 1-5 ppm (dry weight). The renal slices are thin targets that yield X-ray emission spectra with low backgrounds and high elemental sensitivities. The nondestructive nature of PIXE and the ability to simultaneously measure uptake of multiple metals and endogenous elements are unique to this methodology. Key words. arsenic, cadmium, chromium, elemental analysis, interactive toxicity, mercury, metal analysis, nephrotoxicity, proton-induced X-ray emission (PIXE), X-ray emission.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 30 条
[1]   ELIMINATION OF CHARGING IN PROTON-INDUCED X-RAY-EMISSION ANALYSIS OF INSULATING SAMPLES [J].
AHLBERG, M ;
JOHANSSON, G ;
MALMQVIST, K .
NUCLEAR INSTRUMENTS & METHODS, 1975, 131 (02) :377-379
[2]   TISSUE SLICING AND CULTURING REVISITED [J].
BRENDEL, K ;
GANDOLFI, AJ ;
KRUMDIECK, CL ;
SMITH, PF .
TRENDS IN PHARMACOLOGICAL SCIENCES, 1987, 8 (01) :11-15
[3]  
CABRI LJ, 1985, CAN MINERAL, V23, P133
[4]   SPECIMEN PREPARATION IN PIXE ANALYSIS [J].
CAMPBELL, JL .
NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (1-2) :263-273
[5]   OPTIMIZATION OF PIXE SENSITIVITY FOR BIOMEDICAL APPLICATIONS [J].
CAMPBELL, JL ;
RUSSELL, SB ;
FAIQ, S ;
SCHULTE, CW ;
OLLERHEAD, RW ;
GINGERICH, RR .
NUCLEAR INSTRUMENTS & METHODS, 1981, 181 (1-3) :285-292
[6]   PRACTICAL PROBLEMS WITH A PROTON PROBE [J].
CAMPBELL, JL ;
TEESDALE, WJ ;
MAXWELL, JA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 56-7 :694-698
[7]  
Chu W.-K., 1978, BACKSCATTERING SPECT
[8]   ANALYTICAL APPLICATION OF PARTICLE INDUCED X-RAY-EMISSION [J].
JOHANSSON, SAE ;
JOHANSSON, TB .
NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (03) :473-516
[9]  
JOHANSSON SAE, 1988, PIXE NOVEL TECHNIQUE, P134
[10]   X-RAY ANALYSIS - ELEMENTAL TRACE ANALYSIS AT 10-12G LEVEL [J].
JOHANSSON, TB ;
AKSELSSON, R ;
JOHANSSON, SA .
NUCLEAR INSTRUMENTS & METHODS, 1970, 84 (01) :141-+