LOW-PRESSURE MEMBRANES - ASSESSING INTEGRITY

被引:0
作者
ADHAM, SS
JACANGELO, JG
LAINE, JM
机构
[1] MONTGOMERY WATSON,HERNDON,VA 22070
[2] LYONNAISSE EAUX DOMEZ,LE PECQ,FRANCE
来源
JOURNAL AMERICAN WATER WORKS ASSOCIATION | 1995年 / 87卷 / 03期
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Several methods for monitoring the integrity of low-pressure membranes were identified and evaluated using pilot-scale systems. These techniques included particle counting, particle monitoring, turbidity monitoring, bubble-point testing, air-pressure-hold testing, and sonic sensing. Although it does not provide continuous integrity monitoring throughout the filtration cycle, the air-pressure-hold test was the most effective direct monitoring method. Of the technique that provide continuous monitoring, particle counting was the most sensitive.
引用
收藏
页码:62 / 75
页数:14
相关论文
共 18 条
[1]  
ADHAM S, 1993, THESIS U ILLINOIS UR
[2]  
ADHAM SS, 1994, ASCE CRITICAL ISSUES
[3]  
ADHAM SS, 1991 P AWWA ANN C NE
[4]  
BERSILLON JL, 1991 AWWA MEMBR TECH
[5]  
CHERYAN M, 1988, ULTRAFILTRATION HDB
[6]  
DUCLERT F, 1990, 5TH WORLD FILT C NIC
[7]  
HENEGHAN KS, 1991 AWWA MEMBR TECH
[8]  
JACANGELO JG, 1989, J AM WATER WORKS ASS, V81, P68
[9]  
JACANGELO JG, 1991, J AM WATER WORKS ASS, V83, P97
[10]  
LAINE JM, 1989, J AM WATER WORKS ASS, V81, P61