A BIO-FET SENSOR FOR LACTOSE BASED ON CO-IMMOBILIZED BETA-GALACTOSIDASE GLUCOSE-DEHYDROGENASE

被引:22
|
作者
SEVILLA, F
KULLICK, T
SCHEPER, T
机构
[1] UNIV MUNSTER,INST BIOCHEM,WILHELM KLEMM STR 2,D-48149 MUNSTER,GERMANY
[2] UNIV ST TOMAS ESPANA,NAT SCI RES CTR,MANILA 1008,PHILIPPINES
[3] UNIV HANNOVER,INST TECH CHEM,D-30167 HANNOVER,GERMANY
来源
BIOSENSORS & BIOELECTRONICS | 1994年 / 9卷 / 4-5期
关键词
BIOFET SENSOR; ENZYME FET SENSOR; LACTOSE SENSOR; CO-IMMOBILIZED BETA-GALACTOSIDASE GLUCOSE DEHYDROGENASE;
D O I
10.1016/0956-5663(94)80024-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A field-effect transistor (FET) biosensor for lactose is presented. The bioFET device employs a bi-enzyme system consisting of beta-galactosidase and glucose dehydrogenase co-immobilized on the surface of the FET gate. The sensor response was measured in a differential mode, wherein the source voltage in the bioFET is compared with that in a pH-sensitive FET sensor placed next to it. The sensor produced a rapid and reproducible response to lactose. The response was affected by several factors such as stirring, NAD+ concentration, pH and buffer capacity. The optimum conditions for the performance of the bioFET were investigated.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 10 条
  • [1] SIMULATION OF BATCH AND CONTINUOUS REACTORS WITH CO-IMMOBILIZED YEAST AND BETA-GALACTOSIDASE
    AXELSSON, A
    ZACCHI, G
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 1991, 52 (04) : 481 - 497
  • [3] Conductometric biosensor based on glucose oxidase and beta-galactosidase for specific lactose determination in milk
    Marrakchi, Mouna
    Dzyadevych, Sergei V.
    Lagarde, Florence
    Martelet, Claude
    Jaffrezic-Renault, Nicole
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (5-6): : 872 - 875
  • [4] Flexible Enzyme-Free Gate Engineered Bio-FET Glucose Sensor Based on Nickel-Tungstate Microcrystals
    Farahmandpour, Milad
    Ansari, Hamid Reza
    Kordrostami, Zoheir
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 9308 - 9316
  • [5] The sandy of microdialysis glucose sensor system based on co-immobilized peroxidase with glucose oxidase by sol-gel technique
    Yu, P
    Chen, YQ
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 415 - 416
  • [6] Co-immobilized glucose oxidase and β-galactosidase on bovine serum albumin coated allyl glycidyl ether (AGE)-ethylene glycol dimethacrylate (EGDM) copolymer as a biosensor for lactose determination in milk
    Jasti, Lakshmi Swarnalatha
    Dola, Sandhya Rani
    Fadnavis, Nitin W.
    Addepally, Uma
    Daniels, Siona
    Ponrathnam, Surendra
    ENZYME AND MICROBIAL TECHNOLOGY, 2014, 64-65 : 67 - 73
  • [7] AMPEROMETRIC GLUCOSE SENSOR BASED ON GLUCOSE-DEHYDROGENASE IMMOBILIZED ON A GRAPHITE ELECTRODE MODIFIED WITH AN N, N'-BIS(BENZOPHENOXAZINYL) DERIVATIVE OF BENZENE-1,4-DICARBOXAMIDE
    POLASEK, M
    GORTON, L
    APPELQVIST, R
    MARKOVARGA, G
    JOHANSSON, G
    ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 283 - 292
  • [8] Amperometric tetrathiafulvalene-mediated sensor sensitive to reduced nicotinamide adenine dinucleotide based on co-immobilized lactate oxidase and lactate dehydrogenase
    Zhang, XL
    Liu, HY
    Wu, XX
    Qi, DY
    Zhang, ZY
    Dai, M
    Deng, JQ
    Feng, F
    ANALYTICAL COMMUNICATIONS, 1996, 33 (03): : 111 - 114
  • [9] FLOW-INJECTION ANALYSIS OF LACTOSE USING COVALENTLY IMMOBILIZED BETA-GALACTOSIDASE, MUTAROTASE, AND GLUCOSE-OXIDASE PEROXIDASE ON A 2-FLUORO-1-METHYLPYRIDINIUM SALT-ACTIVATED FRACTOGEL SUPPORT
    NARINESINGH, D
    STOUTE, VA
    DAVIS, G
    NGO, TT
    ANALYTICAL BIOCHEMISTRY, 1991, 194 (01) : 16 - 24
  • [10] HIGHLY SELECTIVE AND SENSITIVE DETECTION OF NADP COENZYMES USING CO-IMMOBILIZED GLUCOSE-6-PHOSPHATE-DEHYDROGENASE DIAPHORASE REACTORS AS ONLINE AMPLIFIERS BASED ON SUBSTRATE RECYCLING IN A CHEMILUMINOMETRIC FLOW-INJECTION SYSTEM
    YAO, T
    OGAWA, H
    NAKAHARA, T
    TALANTA, 1995, 42 (09) : 1297 - 1303