CAROTID-ARTERY STENOSIS - REASSESSMENT OF THE DOPPLER CRITERIA

被引:8
作者
HARTNELL, GG
GIBSON, RN
WILLIAMS, R
HEMINGWAY, AP
机构
[1] Department of Diagnostic Radiology, Royal Postgraduate Medical School, Hammersmith Hospital, London
关键词
Carotid arteries; digital subtraction angiography; disease; flow study; ultrasound study;
D O I
10.1016/0720-048X(90)90125-U
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Few previous studies of the accuracy of duplex Doppler in the assessment of carotid artery stenosis have looked at the accuracy in excluding disease in populations with a significant number of normal arteries. In addition, few studies have compared different criteria for stenosis. Duplex Doppler was used to evaluate the carotid arteries in 80 patients. Two well-described methods for analysing Doppler traces were used and the results were compared with those obtained from non-selective digital subtraction angiography. On the basis of these findings, the Doppler criteria used for carotid stenosis were redefined in terms of changes in peak velocity rather than Doppler frequency shift. Using these criteria, the sensitivity of Doppler in identifying carotid stenosis was 97% (98% sensitivity for > 50% stenosis) and specificity was increased from 84% to 93%. © 1990.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 17 条
  • [1] Blackshear, Philips, Thiele, Hirsch, Chikos, Marinelli, Ward, Strandness, Detection of carotid occulusive disease by ultrasonic imaging and pulsed Doppler spectrum analysis, Surgery, 86, pp. 698-706, (1979)
  • [2] Ratliff, Haines, Humphries, Birch, Chant, The reliability of Doppler ultrasound techniques in the assessment of carotid disease, Angiology, 36, pp. 333-340, (1985)
  • [3] Sheldon, Janowitz, Loborgne, Sisna, Rojo, Intravenous DSA of extracranial carotid lesions: comparison with other techniques and specimens, AJR, 143, pp. 1289-1294, (1984)
  • [4] James, Earnest, Forbes, Reese, Houser, Folger, High-resolution dynamic ultrasound imaging of the carotid bifurcation: a prospective evaluation, Radiology, 144, pp. 853-858, (1982)
  • [5] Reilly, Lusky, Hughes, Ferrell, Steony, Ehrenfeld, Carotid plaque histology using real-time ultrasonography: clinical and therapeutic implications, Am J Surg, 146, pp. 188-193, (1983)
  • [6] Wood, Lukin, Tomsick, Chambers, Digital subtraction angiography with intravenous injection: assessment of 1000 carotid bifurcations, AJR, 140, pp. 855-859, (1983)
  • [7] Barter, Kerslake, Barbir, Scnheidan, Stevens, Impact of IV-DSA in the management of cerebrovascular disease: safety and efficacy, Clin Radiol, 39, (1988)
  • [8] Earnest, Forbes, Sandok, Piepgras, Faust, Ilstrup, Amadt, Complications of cerebral angiography: prospective assessment of risk, AJR, 142, pp. 247-253, (1984)
  • [9] Jeans, MacKenzie, Baird, Angiography in transient cerebral ischaemia using three views of the carotid bifurcation, Br J Radiol, 59, pp. 134-142, (1986)
  • [10] Jeans, Fernando, Sheddon, Aldoori, Baird, The place of duplex scanning in the investigation of patients with TIAs, Br J Radiol, 57, (1984)