A COMPARISON OF ULTRASOUND EXPOSURE IN THERAPY AND PULSED DOPPLER FIELDS

被引:7
作者
STARRITT, HC
DUCK, FA
机构
关键词
DIAGNOSTIC ULTRASOUND; THERAPEUTIC ULTRASOUND; EXPOSURE; MEASUREMENT;
D O I
10.1259/0007-1285-65-775-557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A detailed comparison of the ultrasound exposure in water from a therapeutic beam and a pulsed Doppler beam was carried out. A significant overlap in acoustic power was found between therapy intensity levels used clinically and the upper end of the diagnostic range, between approximately 100 mW and 200 mW. In addition, pulse pressure amplitudes in the range 0.5-1.0 MPa were measured close to the transducer on both units. It is common to use physiotherapy equipment at pulse average intensities of 0.5 W/cm2 or less, and at these levels exposures of similar magnitude may be obtained with beams currently defined as therapeutic and those available from pulsed Doppler equipment.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [21] Low-intensity pulsed ultrasound: Nonunions
    Dijkman, Bernadette G.
    Sprague, Sheila
    Bhandari, Mohit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2009, 43 (02) : 141 - 148
  • [22] Low-Intensity Pulsed Ultrasound Accelerates Healing in Rat Calcaneus Tendon Injuries
    Jeremias Junior, Sergio Luiz
    Camanho, Gilberto Luis
    Bassit, Ana Cristina Ferreira
    Forgas, Andrea
    Ingham, Sheila J. M.
    Abdalla, Rene Jorge
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2011, 41 (07) : 526 - 531
  • [23] Measurement of Thermal Effects of Doppler Ultrasound: An In Vitro Study
    Helmy, Samir
    Bader, Yvonne
    Koch, Marianne
    Tiringer, Denise
    Kollmann, Christian
    PLOS ONE, 2015, 10 (08):
  • [24] MEASUREMENT OF BLOOD PERFUSION IN TISSUE USING DOPPLER ULTRASOUND
    DYMLING, SO
    PERSSON, HW
    HERTZ, CH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (05) : 433 - 444
  • [25] Standardization of ultrasound exposure reporting for bio-effects and safety studies
    ter Haar, Gail
    ULTRASOUND, 2010, 18 (01) : 28 - 30
  • [26] Comparison of Angiogenesis in Bone Defect Healing Process due to the Difference in the Frequency of Low-Intensity Pulsed Ultrasound (LIPUS)
    Sasaki, Hodaka
    Monden, Kazuya
    Yoshinari, Masao
    Yajima, Yasutomo
    JOURNAL OF HARD TISSUE BIOLOGY, 2016, 25 (02) : 157 - 164
  • [27] Occupational exposure to radiofrequency electromagnetic fields
    Stam, Rianne
    INDUSTRIAL HEALTH, 2022, 60 (03) : 201 - 215
  • [28] EFFECT OF PULSED ELECTROMAGNETIC FIELDS ON ENDOPLASMIC RETICULUM STRESS
    Keczan, E.
    Keri, G.
    Banhegyi, G.
    Stiller, I.
    JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2016, 67 (05): : 769 - 775
  • [29] Effects of Pulsed and Sinusoidal Electromagnetic Fields on Rat Testes
    Tunik, Selcuk
    Baran, Ozlem Pamukcu
    Akpolat, Veysi
    Ayaz, Ercan
    Nergiz, Yusuf
    Celik, M. Salih
    Yumusak, Ozkan
    ANALYTICAL AND QUANTITATIVE CYTOPATHOLOGY AND HISTOPATHOLOGY, 2020, 42 (03): : 77 - 84