A COMPARISON OF ULTRASOUND EXPOSURE IN THERAPY AND PULSED DOPPLER FIELDS

被引:7
|
作者
STARRITT, HC
DUCK, FA
机构
来源
BRITISH JOURNAL OF RADIOLOGY | 1992年 / 65卷 / 775期
关键词
DIAGNOSTIC ULTRASOUND; THERAPEUTIC ULTRASOUND; EXPOSURE; MEASUREMENT;
D O I
10.1259/0007-1285-65-775-557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A detailed comparison of the ultrasound exposure in water from a therapeutic beam and a pulsed Doppler beam was carried out. A significant overlap in acoustic power was found between therapy intensity levels used clinically and the upper end of the diagnostic range, between approximately 100 mW and 200 mW. In addition, pulse pressure amplitudes in the range 0.5-1.0 MPa were measured close to the transducer on both units. It is common to use physiotherapy equipment at pulse average intensities of 0.5 W/cm2 or less, and at these levels exposures of similar magnitude may be obtained with beams currently defined as therapeutic and those available from pulsed Doppler equipment.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [11] DEVELOPMENTAL EXPOSURE OF MICE TO PULSED ULTRASOUND
    KIMMEL, CA
    STRATMEYER, ME
    GALLOWAY, WD
    BROWN, NT
    LABORDE, JB
    BATES, HK
    TERATOLOGY, 1987, 35 (02) : A54 - A54
  • [12] DEVELOPMENTAL EXPOSURE OF MICE TO PULSED ULTRASOUND
    KIMMEL, CA
    STRATMEYER, ME
    GALLOWAY, WD
    BROWN, NT
    LABORDE, JB
    BATES, HK
    TERATOLOGY, 1989, 40 (04) : 387 - 393
  • [13] PULSED DOPPLER ULTRASOUND OF THE UMBILICAL ARTERIES TO ASSESS THE FETOPLACENTAL VESSEL TREE - A PROSPECTIVE HISTOLOGICAL COMPARISON
    HITSCHOLD, T
    MUNTEFERING, H
    BERLE, P
    ULTRASCHALL IN DER MEDIZIN, 1992, 13 (04): : 162 - 165
  • [14] Comparison of unenhanced helical CT scanning and pulsed Doppler ultrasound in the evaluation of acute renal obstruction
    RosenfieldDarling, ML
    Neitlich, JD
    Scoutt, LM
    Smith, RC
    RADIOLOGY, 1997, 205 : 1551 - 1551
  • [15] SENSITIVITY AND SPECIFICITY OF DOPPLER ULTRASOUND IN THE DETECTION OF VALVULAR REGURGITATION - COMPARISON OF CONTINUOUS AND PULSED WAVE TECHNIQUES
    KWAN, OL
    HANDSHOE, R
    HANDSHOE, SD
    JONES, P
    SMITH, MD
    DEMARIA, AN
    CIRCULATION, 1983, 68 (04) : 229 - 229
  • [16] Transit time broadening: A pulsed Doppler ultrasound perspective
    Yu, ACH
    Steinman, AH
    Lui, EYL
    Cobbold, RSC
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 2113 - 2116
  • [17] RANGE AMBIGUITY IN PULSED DOPPLER ULTRASOUND - THE AMBIGUITY CLARIFIED
    JAWAD, IA
    TAYLOR, ML
    PRUITTHUDSON, F
    YOUNG, HS
    JOURNAL OF CLINICAL ULTRASOUND, 1985, 13 (07) : 475 - 479
  • [18] Optimized GPU Framework for Pulsed Wave Doppler Ultrasound
    Wang, Li
    Shi, Dan
    Liu, Dong C.
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [19] REGIONAL MYOCARDIAL THICKENING MEASURED BY PULSED DOPPLER ULTRASOUND
    HARTLEY, CJ
    LEWIS, RM
    LATSON, LA
    ENTMAN, ML
    CIRCULATION, 1981, 64 (04) : 67 - 67
  • [20] TRACKING OF FETAL BREATHING MOVEMENTS BY PULSED DOPPLER ULTRASOUND
    SHINOZUKA, N
    YAMAKOSHI, Y
    OKAI, T
    MIZUNO, M
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1991, 1 (03) : 202 - 207