A COMPARISON OF ULTRASOUND EXPOSURE IN THERAPY AND PULSED DOPPLER FIELDS

被引:7
|
作者
STARRITT, HC
DUCK, FA
机构
来源
BRITISH JOURNAL OF RADIOLOGY | 1992年 / 65卷 / 775期
关键词
DIAGNOSTIC ULTRASOUND; THERAPEUTIC ULTRASOUND; EXPOSURE; MEASUREMENT;
D O I
10.1259/0007-1285-65-775-557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A detailed comparison of the ultrasound exposure in water from a therapeutic beam and a pulsed Doppler beam was carried out. A significant overlap in acoustic power was found between therapy intensity levels used clinically and the upper end of the diagnostic range, between approximately 100 mW and 200 mW. In addition, pulse pressure amplitudes in the range 0.5-1.0 MPa were measured close to the transducer on both units. It is common to use physiotherapy equipment at pulse average intensities of 0.5 W/cm2 or less, and at these levels exposures of similar magnitude may be obtained with beams currently defined as therapeutic and those available from pulsed Doppler equipment.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF PULSED DOPPLER ULTRASOUND AND ANGIOGRAPHY IN THE PORTAL-HYPERTENSION PATIENT
    NELSON, RC
    LOVETT, KE
    CHEZMAR, JL
    MOYERS, JH
    TORRES, WE
    MURPHY, FB
    BERNARDINO, ME
    SOUTHERN MEDICAL JOURNAL, 1987, 80 (09) : 69 - 69
  • [2] GLYCOPROTEIN AND GANGLIOSIDE CHANGES IN HUMAN TROPHOBLASTS AFTER EXPOSURE TO PULSED DOPPLER ULTRASOUND
    HEFFERLAUC, M
    LATIN, V
    BREYER, B
    FLOGEL, M
    MULLER, WEG
    LAUC, G
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (04): : 579 - 584
  • [3] PULSED ULTRASOUND DOPPLER IN CARDIAC MONITORING
    LANGJENSEN, T
    CHRISTENSEN, T
    NYGAARD, E
    ACTA PHYSIOLOGICA SCANDINAVICA, 1984, 121 (03): : A27 - A27
  • [4] LIMITS OF DOPPLER COOLING IN PULSED LASER FIELDS
    MOLMER, K
    PHYSICAL REVIEW LETTERS, 1991, 66 (18) : 2301 - 2304
  • [5] DEVICE FOR TEACHING THE PRINCIPLES OF PULSED DOPPLER ULTRASOUND
    KUNI, CC
    JOURNAL OF CARDIOVASCULAR ULTRASONOGRAPHY, 1988, 7 (03): : 269 - 272
  • [6] PULSED DOPPLER ULTRASOUND IMAGING OF THE VERTEBRAL ARTERY
    WOOD, CPL
    MEIRE, HB
    BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (634): : 1028 - 1028
  • [7] PULSED DOPPLER ULTRASOUND FOR MEASUREMENT OF UTEROPLACENTAL PERFUSION
    SKODLER, WD
    PHILIPP, K
    PATEISKY, N
    SAGL, R
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 1987, 242 (1-4) : 741 - 741
  • [8] ASSESSMENT OF HEMODYNAMIC FUNCTION WITH PULSED DOPPLER ULTRASOUND
    BERMAN, W
    ALVERSON, DC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (01) : S104 - S112
  • [9] EXAMINATION OF THE PRECEREBRAL ARTERIES WITH PULSED DOPPLER ULTRASOUND
    ROSJO, O
    ACTA NEUROLOGICA SCANDINAVICA, 1983, 67 (04): : 251 - 251
  • [10] DIAGNOSIS OF RENAL PSEUDOANEURYSMS BY PULSED DOPPLER ULTRASOUND
    CHOU, YH
    TIU, CM
    PAN, HB
    SU, YG
    CHANG, T
    JOURNAL OF CLINICAL ULTRASOUND, 1985, 13 (09) : 662 - 666