ASSESSING THE IMPACT OF BLOOD-SAMPLE TYPE ON THE ESTIMATED PREVALENCE OF IMPAIRED GLUCOSE-TOLERANCE AND DIABETES-MELLITUS IN EPIDEMIOLOGIC SURVEYS

被引:14
作者
FARRER, M
ALBERS, CJ
NEIL, HAW
ADAMS, PC
LAKER, MF
ALBERTI, KGMM
机构
[1] UNIV NEWCASTLE UPON TYNE,SCH MED,DEPT CARDIOL,NEWCASTLE TYNE NE4 4HH,TYNE & WEAR,ENGLAND
[2] UNIV NEWCASTLE UPON TYNE,SCH MED,DEPT CLIN BIOCHEM,NEWCASTLE TYNE NE4 4HH,TYNE & WEAR,ENGLAND
[3] UNIV NEWCASTLE UPON TYNE,SCH MED,DEPT MED,NEWCASTLE TYNE NE4 4HH,TYNE & WEAR,ENGLAND
[4] RADCLIFFE INFIRM,DEPT PUBL HLTH & PRIMARY CARE,OXFORD OX2 6HE,ENGLAND
关键词
DIABETES MELLITUS; IMPAIRED GLUCOSE TOLERANCE; WHO DIAGNOSTIC CRITERIA; VENOUS WHOLE BLOOD GLUCOSE; VENOUS PLASMA GLUCOSE;
D O I
10.1111/j.1464-5491.1995.tb00486.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In a prospective study of 353 patients who had undergone coronary artery bypass graft surgery a 75 g oral glucose tolerance test was performed at 3 months and 12 months after surgery. Venous whole blood glucose and venous plasma glucose samples were assayed on a bench-top analyser. The World Health Organization diagnostic criteria for impaired glucose tolerance and diabetes mellitus were applied to venous whole blood glucose and venous plasma glucose measurements. The difference between the plasma and whole blood concentration of glucose was 0.79-0.86 mmol l(-1) at a plasma glucose of 7.8 mmol l(-1) and 1.22-1.24 mmol l(-1) at a plasma glucose of 11.1 mmol l(-1) (compared to 1.1 mmol l(-1) by World Health Organization criteria at both cut-points). Despite this, in our subject population with a high prevalence of impaired glucose tolerance (20.3 % at 3 months, 15.3 % at 12 months) and diabetes mellitus (10.1 % at 3 months and 12 months), there was no significant difference in the proportion classified impaired glucose tolerance or having diabetes mellitus using venous whole blood glucose compared to venous plasma glucose. We conclude that despite the minor anomaly between WHO diagnostic criteria based on venous whole blood glucose and venous plasma glucose measurements, these criteria are robust and give broadly comparable population prevalence of diabetes mellitus and impaired glucose tolerance irrespective of blood sample choice.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 13 条
[1]  
Classification and diagnosis of diabetes mellitus and other categories of glucose tolerance, Diabetes, 28, pp. 1039-1057, (1979)
[2]  
(1985)
[3]  
Niejadlik DC, The glucose tolerance test: An evaluation, Postgrad Med, 55, pp. 73-78, (1974)
[4]  
Neely RDG, Kiwanuka JB, Hadden DR, Influence of sample type on the interpretation of the oral glucose tolerance test for gestational diabetes mellitus, Diabetic Medicine, 8, pp. 129-134, (1991)
[5]  
Farrer M., Game FL, Albers CJ, Neil HAW, Winocour PH, Laker MF, Et al., Association between impaired glucose tolerance and circulating concentration of Lp(a) lipoprotein in relation to coronary artery disease, Br Med J, 307, pp. 832-836, (1993)
[6]  
Bland JM, Altman DG, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, 1, pp. 307-310, (1986)
[7]  
Fuller JH, Shipley MJ, Rose G., Jarrett RJ, Keen H., Coronary‐heart‐disease‐risk and impaired glucose tolerance: the Whitehall study, Lancet, 1, pp. 1374-1376, (1980)
[8]  
Jarrett RJ, Keen H., Fuller JH, McCartney M., Worsening to diabetes in men with impaired glucose tolerance (‘borderline diabetes’), Diabetologia, 16, pp. 25-30, (1979)
[9]  
Keen H., Jarrett RJ, McCartney P., The ten‐year follow‐up of the Bedford survey (1962–1972): glucose tolerance and diabetes, Diabetologia, 22, pp. 73-78, (1982)
[10]  
Saad MF, Knowler WC, Pettitt DJ, Nelson RG, Mott DM, Bennett PH, The natural history of impaired glucose tolerance in Pima Indians, N Engl J Med, 319, pp. 1500-1506, (1988)