Prospective study on dosimetric comparison of helical tomotherapy and 3DCRT for craniospinal irradiation - A single institution experience

被引:14
作者
Bandurska-Luque, Anna [1 ]
Piotrowski, Tomasz [2 ,3 ]
Skrobala, Agnieszka [2 ,3 ]
Ryczkowski, Adam [3 ]
Adamska, Krystyna [4 ]
Kazmierska, Joanna [1 ,2 ]
机构
[1] Greater Poland Canc Ctr, Radiotherapy Dept 2, Poznan, Poland
[2] Univ Med Sci, Dept Electroradiol, Poznan, Poland
[3] Greater Poland Canc Ctr, Med Phys Dept, Poznan, Poland
[4] Greater Poland Canc Ctr, Radiotherapy Dept 3, Poznan, Poland
关键词
Craniospinal irradiation; Helical tomotherapy; Dosimetric comparison;
D O I
10.1016/j.rpor.2014.12.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: This prospective study aims to assess feasibility of helical tomotherapy (HT) for craniospinal irradiation (CSI) and perform dosimetric comparison of treatment plans for both HT and 3D conformal radiotherapy (3DCRT). Background: CSI is a challenging procedure. Large PTV size requires field matching due to technical limitations of standard linear accelerators, which cannot irradiate such volumes as a single field. HT could help to avoid these limitations as irradiation of long fields is possible without field matching. Materials and methods: Three adults were enrolled from 2009 to 2010. All patients received radiochemotherapy. Treatment plans in prone position for 3DCRT and in supine position for HT were generated. The superior plan was used for patients' irradiation. Plans were compared with the application of DVH, Dx parameters - where x represents a percentage of the structure volume receiving a normalized dose and homogeneity index (HI). Results: All patients received HT irradiation. The treatment was well tolerated. The HT plans resulted in a better dose coverage and uniformity in the PTV: HI were 5.4, 7.8, 6.8 for HT vs. 10.3, 6.6, 10.4 for 3DCRT. For most organs at risk (OARs), the D(V80) was higher for HT than for 3DCRT, whereas D(V5) was lower for HT. Conclusions: HT is feasible for CSI, and in comparison with 3DCRT it improves PTV coverage. HT reduces high dose volumes of OARs, but larger volumes of normal tissue receive low radiation dose. HT requires further study to establish correlations between dosimetrical findings and clinical outcomes, especially with regard to late sequelae of treatment. (C) 2015 Greater Poland Cancer Centre. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 37 条
[31]   Dosimetric comparison of four different external beam partial breast irradiation techniques: Three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy [J].
Moon, Sung Ho ;
Shin, Kyung Hwan ;
Kim, Tae Hyun ;
Yoon, Myonggeun ;
Park, Soah ;
Lee, Doo-Hyun ;
Kim, Jong Won ;
Kim, Dae Woong ;
Park, Sung Yong ;
Cho, Kwan Ho .
RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) :66-73
[32]   Safety of total body irradiation using intensity-modulated radiation therapy by helical tomotherapy in allogeneic hematopoietic stem cell transplantation: a prospective pilot study [J].
Konishi, Tatsuya ;
Ogawa, Hiroaki ;
Najima, Yuho ;
Hashimoto, Shinpei ;
Wada, Atsushi ;
Adachi, Hiroto ;
Konuma, Ryosuke ;
Kishida, Yuya ;
Nagata, Akihito ;
Yamada, Yuta ;
Kaito, Satoshi ;
Mukae, Junichi ;
Marumo, Atsushi ;
Noguchi, Yuma ;
Toya, Takashi ;
Igarashi, Aiko ;
Kobayashi, Takeshi ;
Ohashi, Kazuteru ;
Doki, Noriko ;
Karasawa, Katsuyuki .
JOURNAL OF RADIATION RESEARCH, 2020, 61 (06) :969-976
[33]   Outcomes of allogeneic haematopoietic stem cell transplantation with intensity-modulated total body irradiation by helical tomotherapy: a 2-year prospective follow-up study [J].
Konishi, Tatsuya ;
Ogawa, Hiroaki ;
Najima, Yuho ;
Hashimoto, Shinpei ;
Kito, Satoshi ;
Atsuta, Yuya ;
Wada, Atsushi ;
Adachi, Hiroto ;
Konuma, Ryosuke ;
Kishida, Yuya ;
Nagata, Akihito ;
Yamada, Yuta ;
Kaito, Satoshi ;
Mukae, Junichi ;
Marumo, Atsushi ;
Noguchi, Yuma ;
Shingai, Naoki ;
Toya, Takashi ;
Igarashi, Aiko ;
Shimizu, Hiroaki ;
Kobayashi, Takeshi ;
Ohashi, Kazuteru ;
Doki, Noriko ;
Murofushi, Keiko Nemoto .
ANNALS OF MEDICINE, 2022, 54 (01) :2616-2625
[34]   Dosimetric comparison of helical tomotherapy, VMAT, fixed-field IMRT and 3D-conformal radiotherapy for stage I-II nasal natural killer T-cell lymphoma [J].
Liu, Xianfeng ;
Huang, Erliang ;
Wang, Ying ;
He, Yanan ;
Luo, Huanli ;
Zhong, Mingsong ;
Qiu, Da ;
Li, Chao ;
Yang, Han ;
He, Guanglei ;
Zhou, Juan ;
Jin, Fu .
RADIATION ONCOLOGY, 2017, 12
[35]   Dosimetric comparison of helical tomotherapy, VMAT, fixed-field IMRT and 3D-conformal radiotherapy for stage I-II nasal natural killer T-cell lymphoma [J].
Xianfeng Liu ;
Erliang Huang ;
Ying Wang ;
Yanan He ;
Huanli Luo ;
Mingsong Zhong ;
Da Qiu ;
Chao Li ;
Han Yang ;
Guanglei He ;
Juan Zhou ;
Fu Jin .
Radiation Oncology, 12
[36]   Dosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic cancer [J].
Ekici, Kemal ;
Pepele, Eda K. ;
Yaprak, Bahaddin ;
Ternelli, Oztun ;
Eraslan, Aysun F. ;
Kucuk, Nadir ;
Altinok, Ayse Y. ;
Sut, Pelin A. ;
Alpak, Ozlem D. ;
Colak, Cemil ;
Mayadagli, Alpaslan .
Medical Dosimetry, 2016, 41 (04) :329-333
[37]   Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT) and Helical Tomotherapy for Hippocampal-Avoidance Prophylactic Whole Brain Radiotherapy (HA-PWBRT) in Small Cell Lung Cancer; Treatment Plans Based Study [J].
Dogan, Ozlem Yetmen ;
Cini, Nilsu ;
Can, Sevecen Seyhun Nasir .
MEDICAL JOURNAL OF BAKIRKOY, 2020, 16 (03) :263-271