Prospective study on dosimetric comparison of helical tomotherapy and 3DCRT for craniospinal irradiation - A single institution experience

被引:14
|
作者
Bandurska-Luque, Anna [1 ]
Piotrowski, Tomasz [2 ,3 ]
Skrobala, Agnieszka [2 ,3 ]
Ryczkowski, Adam [3 ]
Adamska, Krystyna [4 ]
Kazmierska, Joanna [1 ,2 ]
机构
[1] Greater Poland Canc Ctr, Radiotherapy Dept 2, Poznan, Poland
[2] Univ Med Sci, Dept Electroradiol, Poznan, Poland
[3] Greater Poland Canc Ctr, Med Phys Dept, Poznan, Poland
[4] Greater Poland Canc Ctr, Radiotherapy Dept 3, Poznan, Poland
关键词
Craniospinal irradiation; Helical tomotherapy; Dosimetric comparison;
D O I
10.1016/j.rpor.2014.12.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: This prospective study aims to assess feasibility of helical tomotherapy (HT) for craniospinal irradiation (CSI) and perform dosimetric comparison of treatment plans for both HT and 3D conformal radiotherapy (3DCRT). Background: CSI is a challenging procedure. Large PTV size requires field matching due to technical limitations of standard linear accelerators, which cannot irradiate such volumes as a single field. HT could help to avoid these limitations as irradiation of long fields is possible without field matching. Materials and methods: Three adults were enrolled from 2009 to 2010. All patients received radiochemotherapy. Treatment plans in prone position for 3DCRT and in supine position for HT were generated. The superior plan was used for patients' irradiation. Plans were compared with the application of DVH, Dx parameters - where x represents a percentage of the structure volume receiving a normalized dose and homogeneity index (HI). Results: All patients received HT irradiation. The treatment was well tolerated. The HT plans resulted in a better dose coverage and uniformity in the PTV: HI were 5.4, 7.8, 6.8 for HT vs. 10.3, 6.6, 10.4 for 3DCRT. For most organs at risk (OARs), the D(V80) was higher for HT than for 3DCRT, whereas D(V5) was lower for HT. Conclusions: HT is feasible for CSI, and in comparison with 3DCRT it improves PTV coverage. HT reduces high dose volumes of OARs, but larger volumes of normal tissue receive low radiation dose. HT requires further study to establish correlations between dosimetrical findings and clinical outcomes, especially with regard to late sequelae of treatment. (C) 2015 Greater Poland Cancer Centre. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 50 条
  • [1] DOSIMETRIC COMPARISON OF TOMOTHERAPY IMRT AND 3DCRT FOR CRANIOSPINAL IRRADIATION
    Bandurska, A.
    Piotrowski, T.
    Skrobala, A.
    Ryczkowski, A.
    Kazmierska, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S259 - S259
  • [2] A dosimetric comparison of 3-dimentional conformal radiotherapy (3DCRT) and helical tomotherapy for craniospinal irradiation
    Swanson, E
    Jursinic, P
    Herman, J
    Lee, W
    Firat, SY
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S265 - S265
  • [3] Comparison of Conventional 3DCRT and IMRT for Craniospinal Irradiation
    Cifter, G.
    Goyal, S.
    Agdam, H.
    Sarfaraz, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E643 - E643
  • [4] Dosimetric Comparison of Left-sided Whole Breast Irradiation with 3DCRT, Segmental IMRT, Helical Tomotherapy, Topotherapy, and IMPT
    Sengbusch, E. R.
    Schubert, L. K.
    Westerly, D. C.
    Gondi, V.
    Krey, G.
    Soisson, E. T.
    Tome, W. A.
    Patel, R. R.
    Mackie, T. R.
    Cannon, G. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S194 - S195
  • [5] Comparative Dosimetric Study of 3DCRT, IMRT and VMAT for Whole-Breast Irradiation Following Breast Conservation: A Single-Institution Experience
    Vasudevan, A.
    Kariyarambath, S.
    Bhasi, S.
    George, P. S.
    Mathew, B. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E13 - E14
  • [6] A dosimetric comparison of two external beam radiotherapy techniques: 3DCRT & Tomotherapy in APBI
    Rajan, R.
    Kunheri, B.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S926 - S928
  • [7] First Experience of Three Dimensional Conformal Radiotherapy (3DCRT) Planning with Helical Tomotherapy
    Chao, M.
    Corry, P.
    Zhang, X.
    Penagaricano, J.
    Ratanatharathorn, V.
    MEDICAL PHYSICS, 2012, 39 (06) : 3805 - 3806
  • [8] Craniospinal radiation delivered by helical tomotherapy: A dosimetric study
    Tomblyn, M. B.
    Hui, S. K.
    Dusenbery, K. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S664 - S664
  • [9] CRANIOSPINAL IRRADIATION USING HELICAL TOMOTHERAPY: THE MCGILL EXPERIENCE
    Bahig, Houda
    Panet-Raymond, Valerie
    Freeman, Carolyn
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S76 - S77
  • [10] A single centre experience of using helical tomotherapy (HT) for craniospinal irradiation (CSI)
    Singhera, M.
    Falco, T.
    Blythe, K.
    Begum, R.
    Greener, T.
    Beaney, R.
    Mikhaeel, N.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S784 - S784