A Monte Carlo simulation of coincidence detection and imaging of gamma-ray cascades with a scintillation camera

被引:4
作者
Pahlka, R. Benton [1 ]
Kappadath, S. Cheenu [1 ]
Mawlawi, Osama R. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, UNIT 1472, POB 301402, Houston, TX 77230 USA
关键词
gamma-ray cascades; coincidence detection; gamma camera;
D O I
10.1088/2057-1976/aad572
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several radionuclei used in nuclear medicine decay through the emission of cascaded gamma-rays. These successively-emitted gamma-rays could potentially be detected in coincidence and then be used to create coincident event-based images. While several groups have considered various ways to leverage the gamma-ray cascade to produce images, the concept of producing images using cascaded gamma rays in coincidence with a dual-head gamma camera has not been previously explored in detail. Given that current dual-head gamma cameras cannot be configured in coincidence mode, the purpose of this work was to explore this concept with In-111 using a Monte Carlo simulation. First, GEANT4 was used to model a dual-head gamma camera and to simulate the decay of the nucleus. The model was then validated using planar data from a physical scanner. The validated model was then used to simulate a point source of In-111 located at the camera isocenter to evaluate the true coincidence efficiency with the detectors oriented at 90 degrees. The noise-equivalent-count-rate (NECR) as a function of timing window resolution was computed for different source activities. A simple reconstruction algorithm was then used to produce coincidence-based images from sources in various configurations. The coincident gamma-ray detection efficiency for a single point source in air with the detector heads oriented at 90 degrees was found to be 6 x 10(-8), independent of the source-to-detector distance. The time window resolution for the maximum NECR ranged between 200 and 500 ns, dependent on source activity. The algorithm could produce images over a range of timing window resolutions, with varying levels of reconstruction artifacts. Images produced from a small acrylic phantom showed that scattered events produced small degradations in resolution and contrast-to-noise ratios. This work described the conditions under which images based on coincident events from In-111 could be created using a dual head gamma camera, assuming appropriate electronics modifications.
引用
收藏
页数:18
相关论文
共 50 条
[41]   Monte Carlo simulation of Ray-Scan 64 PET system and performance evaluation using GATE toolkit [J].
Li, Suying ;
Zhang, Qiushi ;
Vuletic, Ivan ;
Xie, Zhaoheng ;
Yang, Kun ;
Ren, Qiushi .
JOURNAL OF INSTRUMENTATION, 2017, 12
[42]   Imaging characterization of a new gamma ray detector based on CRY019 scintillation crystal for PET and SPECT applications [J].
Polito, C. ;
Pani, R. ;
Trigila, C. ;
Cinti, M. N. ;
Fabbri, A. ;
Frantellizzi, V. ;
De Vincentis, G. ;
Pellegrini, R. ;
Pani, R. .
JOURNAL OF INSTRUMENTATION, 2017, 12
[43]   Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study [J].
Kim, Ho Chul ;
Kim, Hee-Joung ;
Kim, Kyuseok ;
Lee, Min-Hee ;
Lee, Youngjin .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (04) :776-780
[44]   SPECT imaging properties of the CdTe-Timepix3 detector used in a new prototype FullSPECT 3D multimodal preclinical imaging system: Comparison with scintillation gamma camera [J].
Modry, Adam ;
Dammer, Jiri ;
Trojanova, Eliska ;
Jakubek, Jan ;
Sykora, Viktor ;
Sefc, Ludek .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1032
[45]   Study on High Density Scintillators and Multi-energy Windows for Improving I-131 Gamma Image Quality: Monte Carlo Simulation Approach [J].
Kim, Minho ;
Bae, Jae Keon ;
Hong, Bong Hwan ;
Kim, Kyeong Min ;
Lee, Wonho .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (03) :305-311
[46]   Study on High Density Scintillators and Multi-energy Windows for Improving I-131 Gamma Image Quality: Monte Carlo Simulation Approach [J].
Minho Kim ;
Jae Keon Bae ;
Bong Hwan Hong ;
Kyeong Min Kim ;
Wonho Lee .
Journal of the Korean Physical Society, 2019, 74 :305-311
[47]   Feasibility of a CdTe-based SPECT for high-resolution low-dose small animal imaging: a Monte Carlo simulation study [J].
Park, S. -J. ;
Yu, A. R. ;
Lee, Y. -J. ;
Kim, Y. -S. ;
Kim, H. -J. .
JOURNAL OF INSTRUMENTATION, 2014, 9
[48]   A Monte Carlo study comparing dead-time losses of a gamma camera between tungsten functional paper and lead sheet for dosimetry in targeted radionuclide therapy with Lu-177 [J].
Nakanishi, Kohei ;
Fujita, Naotoshi ;
Iwanaga, Haruna ;
Asano, Yuki ;
Abe, Shinji ;
Nishii, Ryuichi ;
Kato, Katsuhiko .
ANNALS OF NUCLEAR MEDICINE, 2025, 39 (02) :199-207
[49]   Detectors for high-resolution gamma-ray imaging based on a single CsI (T1) scintillator coupled to an array of silicon drift detectors [J].
Fiorini, C ;
Longoni, A ;
Perotti, F ;
Labanti, C ;
Rossi, E ;
Lechner, P ;
Strüder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :346-350
[50]   Time encoded imaging of extended gamma-ray sources in 3D using the OrionUM pixelated CdZnTe with subpixel estimation and depth of interaction corrections [J].
Shy, D. ;
Petryk, M. ;
Chen, Z. ;
Thompson, S. ;
He, Z. .
JOURNAL OF INSTRUMENTATION, 2021, 16 (03)