ELECTRICALLY EVOKED WHOLE-NERVE ACTION-POTENTIALS - PARAMETRIC DATA FROM THE CAT
被引:65
作者
:
BROWN, CJ
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
BROWN, CJ
[
1
]
ABBAS, PJ
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
ABBAS, PJ
[
1
]
机构
:
[1]
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
来源
:
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA
|
1990年
/ 88卷
/ 05期
关键词
:
D O I
:
10.1121/1.400117
中图分类号
:
O42 [声学];
学科分类号
:
070206 ;
082403 ;
摘要
:
In a companion paper [Brown et al., J. Acoust. Soc. Am. 88, 1385–1391 (1990)], a method for recording the electrically evoked whole-nerve action potential in human cochlear implant users was reported. The procedure for recording the response requires that two biphasic current pulses, a “masker” and a “probe, ” be presented at a rate and level sufficient to drive the auditory nerve into a refractory state. The present study was designed to assess the sensitivity of that recording technique to variations in stimulation parameters. The experiments described in this paper demonstrate that: (1) the EAP as recorded in the cat is triphasic and is defined by two negative peaks occurring at latencies of approximately 0.26 and 0.82 ms; (2) EAP amplitude is independent of the level of the masker stimulus for current levels equal to or greater than the current level of the probe stimulus; and (3) the time course of recovery of the EAP from the refractory state is stable over a range of both probe and masker current levels. © 1990, Acoustical Society of America. All rights reserved.
引用
收藏
页码:2205 / 2210
页数:6
相关论文
共 16 条
[1]
ELECTRICALLY EVOKED BRAIN-STEM POTENTIALS IN COCHLEAR IMPLANT PATIENTS WITH MULTI-ELECTRODE STIMULATION
ABBAS, PJ
论文数:
0
引用数:
0
h-index:
0
ABBAS, PJ
BROWN, CJ
论文数:
0
引用数:
0
h-index:
0
BROWN, CJ
[J].
HEARING RESEARCH,
1988,
36
(2-3)
: 153
-
162
[2]
ELECTRICALLY EVOKED WHOLE-NERVE ACTION-POTENTIALS - DATA FROM HUMAN COCHLEAR IMPLANT USERS
BROWN, CJ
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
BROWN, CJ
ABBAS, PJ
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
ABBAS, PJ
GANTZ, B
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
GANTZ, B
[J].
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA,
1990,
88
(03)
: 1385
-
1391
[3]
ACOUSTICALLY DERIVED AUDITORY-NERVE ACTION-POTENTIAL EVOKED BY ELECTRICAL-STIMULATION - AN ESTIMATION OF THE WAVEFORM OF SINGLE UNIT CONTRIBUTION
DESAUVAGE, RC
论文数:
0
引用数:
0
h-index:
0
DESAUVAGE, RC
CAZALS, Y
论文数:
0
引用数:
0
h-index:
0
CAZALS, Y
ERRE, JP
论文数:
0
引用数:
0
h-index:
0
ERRE, JP
ARAN, JM
论文数:
0
引用数:
0
h-index:
0
ARAN, JM
[J].
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA,
1983,
73
(02)
: 616
-
627
[4]
DISCHARGE PATTERNS OF CAT PRIMARY AUDITORY FIBERS WITH ELECTRICAL-STIMULATION OF THE COCHLEA
HARTMANN, R
论文数:
0
引用数:
0
h-index:
0
HARTMANN, R
TOPP, G
论文数:
0
引用数:
0
h-index:
0
TOPP, G
KLINKE, R
论文数:
0
引用数:
0
h-index:
0
KLINKE, R
[J].
HEARING RESEARCH,
1984,
13
(01)
: 47
-
62
[5]
RESPONSES OF CAT AUDITORY-NERVE FIBERS TO BIPHASIC ELECTRICAL-CURRENT PULSES
JAVEL, E
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
JAVEL, E
TONG, YC
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
TONG, YC
SHEPHERD, RK
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
SHEPHERD, RK
CLARK, GM
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
CLARK, GM
[J].
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY,
1987,
96
(01)
: 26
-
30
[6]
EVALUATION OF 8TH NERVE INTEGRITY BY THE ELECTRICALLY EVOKED MIDDLE LATENCY RESPONSE
JYUNG, RW
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
JYUNG, RW
MILLER, JM
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
MILLER, JM
CANNON, SC
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
CANNON, SC
[J].
OTOLARYNGOLOGY-HEAD AND NECK SURGERY,
1989,
101
(06)
: 670
-
682
[7]
Kiang N. Y., 1976, ELECTROCOCHLEOGRAPHY
[8]
PHYSIOLOGICAL CONSIDERATIONS IN ARTIFICIAL STIMULATION OF INNER-EAR
KIANG, NYS
论文数:
0
引用数:
0
h-index:
0
KIANG, NYS
MOXON, EC
论文数:
0
引用数:
0
h-index:
0
MOXON, EC
[J].
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY,
1972,
81
(05)
: 714
-
&
[9]
KILENY PR, 1987, ARCH OTOLARYNGOL, V113, P1072
[10]
Nagal D, 1974, ARCH OTORHINOLARYNG, V206, P293
←
1
2
→
共 16 条
[1]
ELECTRICALLY EVOKED BRAIN-STEM POTENTIALS IN COCHLEAR IMPLANT PATIENTS WITH MULTI-ELECTRODE STIMULATION
ABBAS, PJ
论文数:
0
引用数:
0
h-index:
0
ABBAS, PJ
BROWN, CJ
论文数:
0
引用数:
0
h-index:
0
BROWN, CJ
[J].
HEARING RESEARCH,
1988,
36
(2-3)
: 153
-
162
[2]
ELECTRICALLY EVOKED WHOLE-NERVE ACTION-POTENTIALS - DATA FROM HUMAN COCHLEAR IMPLANT USERS
BROWN, CJ
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
BROWN, CJ
ABBAS, PJ
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
ABBAS, PJ
GANTZ, B
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
GANTZ, B
[J].
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA,
1990,
88
(03)
: 1385
-
1391
[3]
ACOUSTICALLY DERIVED AUDITORY-NERVE ACTION-POTENTIAL EVOKED BY ELECTRICAL-STIMULATION - AN ESTIMATION OF THE WAVEFORM OF SINGLE UNIT CONTRIBUTION
DESAUVAGE, RC
论文数:
0
引用数:
0
h-index:
0
DESAUVAGE, RC
CAZALS, Y
论文数:
0
引用数:
0
h-index:
0
CAZALS, Y
ERRE, JP
论文数:
0
引用数:
0
h-index:
0
ERRE, JP
ARAN, JM
论文数:
0
引用数:
0
h-index:
0
ARAN, JM
[J].
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA,
1983,
73
(02)
: 616
-
627
[4]
DISCHARGE PATTERNS OF CAT PRIMARY AUDITORY FIBERS WITH ELECTRICAL-STIMULATION OF THE COCHLEA
HARTMANN, R
论文数:
0
引用数:
0
h-index:
0
HARTMANN, R
TOPP, G
论文数:
0
引用数:
0
h-index:
0
TOPP, G
KLINKE, R
论文数:
0
引用数:
0
h-index:
0
KLINKE, R
[J].
HEARING RESEARCH,
1984,
13
(01)
: 47
-
62
[5]
RESPONSES OF CAT AUDITORY-NERVE FIBERS TO BIPHASIC ELECTRICAL-CURRENT PULSES
JAVEL, E
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
JAVEL, E
TONG, YC
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
TONG, YC
SHEPHERD, RK
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
SHEPHERD, RK
CLARK, GM
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
UNIV MELBOURNE,DEPT OTOLARYNGOL,PARKVILLE,VIC 3052,AUSTRALIA
CLARK, GM
[J].
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY,
1987,
96
(01)
: 26
-
30
[6]
EVALUATION OF 8TH NERVE INTEGRITY BY THE ELECTRICALLY EVOKED MIDDLE LATENCY RESPONSE
JYUNG, RW
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
JYUNG, RW
MILLER, JM
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
MILLER, JM
CANNON, SC
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
UNIV MICHIGAN,KRESGE HEARING RES INST,ANN ARBOR,MI 48109
CANNON, SC
[J].
OTOLARYNGOLOGY-HEAD AND NECK SURGERY,
1989,
101
(06)
: 670
-
682
[7]
Kiang N. Y., 1976, ELECTROCOCHLEOGRAPHY
[8]
PHYSIOLOGICAL CONSIDERATIONS IN ARTIFICIAL STIMULATION OF INNER-EAR
KIANG, NYS
论文数:
0
引用数:
0
h-index:
0
KIANG, NYS
MOXON, EC
论文数:
0
引用数:
0
h-index:
0
MOXON, EC
[J].
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY,
1972,
81
(05)
: 714
-
&
[9]
KILENY PR, 1987, ARCH OTOLARYNGOL, V113, P1072
[10]
Nagal D, 1974, ARCH OTORHINOLARYNG, V206, P293
←
1
2
→