ELECTRICALLY EVOKED WHOLE-NERVE ACTION-POTENTIALS - PARAMETRIC DATA FROM THE CAT

被引:65
作者
BROWN, CJ [1 ]
ABBAS, PJ [1 ]
机构
[1] UNIV IOWA,DEPT SPEECH PATHOL & AUDIOL,IOWA CITY,IA 52242
关键词
D O I
10.1121/1.400117
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In a companion paper [Brown et al., J. Acoust. Soc. Am. 88, 1385–1391 (1990)], a method for recording the electrically evoked whole-nerve action potential in human cochlear implant users was reported. The procedure for recording the response requires that two biphasic current pulses, a “masker” and a “probe, ” be presented at a rate and level sufficient to drive the auditory nerve into a refractory state. The present study was designed to assess the sensitivity of that recording technique to variations in stimulation parameters. The experiments described in this paper demonstrate that: (1) the EAP as recorded in the cat is triphasic and is defined by two negative peaks occurring at latencies of approximately 0.26 and 0.82 ms; (2) EAP amplitude is independent of the level of the masker stimulus for current levels equal to or greater than the current level of the probe stimulus; and (3) the time course of recovery of the EAP from the refractory state is stable over a range of both probe and masker current levels. © 1990, Acoustical Society of America. All rights reserved.
引用
收藏
页码:2205 / 2210
页数:6
相关论文