A NEW METHOD FOR DETECTION OF UNBALANCE VOLTAGE SUPPLY IN THREE PHASE INDUCTION MOTOR

被引:0
作者
Sheikh, Muhammad Aman [1 ]
Nor, Nursyarizal Mohd [1 ]
Ibrahim, Taib [1 ]
机构
[1] Univ Teknol PETRONAS, Elect & Elect Engn Dept, Tronoh 31750, Perak, Malaysia
来源
JURNAL TEKNOLOGI | 2016年 / 78卷 / 5-8期
关键词
Diagnosis; condition monitoring; inter-turn short circuit; insulation failure; induction motor; rotor slot harmonics; winding insulation;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Induction motors are associated with various techno-economic advantages; therefore these are widely used in residential, commercial and industrial systems. Cost effective and reliable process of condition monitoring of induction motor is very important. It is found that unbalance voltage supply is one of the major factors that produce uneven heating due to reverse current and leads to inter-turn short circuit. The issue regarding unbalanced voltage supply has attracted the attention of researcher and engineers in recent past. In this paper, a new effective non-invasive (online) method is proposed that only use rotor harmonic current signature for the detection of unbalance voltage supply instead of main line current signature. This is a sensor-less and online approach that accomplishes the reliable and accurate analysis of the induction motors. Moreover, it allows a continuous real time tracking without disturbing the normal operation and guarantees the overall production process. Additionally, this method recognizes the unbalance and estimate the severity of the unbalance in the voltage source. The effects of unbalance voltage supply are investigated through experiments. In order to perform the analysis and detect the asymmetry due to unbalance voltage, an experimental set up is designed that can accurately repeat the measurements. In the proposed work, unbalance voltage supply is diagnosed through experimental hardware setup. To validate the propose methods an experiment is performed that confirm that motor operating under unbalance voltage supply give a significant rise in the rotor harmonic while under balance voltage supply there is so such a rise in the rotor harmonic. (C) 2016 Penerbit UTM Press. All rights reserved
引用
收藏
页码:7 / 12
页数:6
相关论文
共 11 条
[1]  
Albrecht P. F., 1986, ENERGY CONVERSION IE, V1, P39
[2]  
Eftekhari M., 2013, EL ENG ICEE 2013 21, P1
[3]   Stator Current and Motor Efficiency as Indicators for Different Types of Bearing Faults in Induction Motors [J].
Frosini, Lucia ;
Bassi, Ezio .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (01) :244-251
[4]   Early Estimation of Faults in Induction Motors Using Symbolic Dynamic-Based Analysis of Stator Current Samples [J].
Gupta, R. A. ;
Wadhwani, A. K. ;
Kapoor, S. R. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) :102-114
[5]  
Joksimovic G. M., IND ELECT IEEE T, V47, P1078
[6]   High-Resolution Parameter Estimation Method to Identify Broken Rotor Bar Faults in Induction Motors [J].
Kim, Yong-Hwa ;
Youn, Young-Woo ;
Hwang, Don-Ha ;
Sun, Jong-Ho ;
Kang, Dong-Sik .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) :4103-4117
[7]  
Moin Siddiqui Khadim, 2012, 2012 International Conference on Computing, Electronics and Electrical Technologies (ICCEET 2012), P1, DOI 10.1109/ICCEET.2012.6203753
[8]  
Nandi S., 2005, EL MACH DRIV IEEE IN, P256
[9]  
Shashidhara S.M., 2013, INT J ADV RES ELECT, V2
[10]  
Tavner L. R. P. J., 2006, CONDITION MONITORING