Conceptual design of the dual X-ray absorptiometry health informatics prediction system for osteoporosis care

被引:0
|
作者
Erjiang, E. [1 ]
Carey, John J. [2 ,3 ]
Wang, Tingyan [1 ,4 ]
Yang, Lan [1 ,5 ]
Chan, Wing P. [6 ]
Whelan, Bryan [2 ,7 ]
Silke, Carmel [2 ,7 ]
O'Sullivan, Miriam [2 ,7 ]
Rooney, Bridie [8 ]
McPartland, Aoife [2 ,7 ]
O'Malley, Grainne [8 ]
Brennan, Attracta [9 ]
Yu, Ming [1 ]
Dempsey, Mary [5 ]
机构
[1] Tsinghua Univ, Dept Ind Engn, Beijing, Peoples R China
[2] Natl Univ Ireland, Sch Med, Galway, Ireland
[3] Galway Univ Hosp, Dept Rheumatol, Galway, Ireland
[4] Univ Oxford, Nuffield Dept Med, Oxford, England
[5] Natl Univ Ireland, Sch Engn, Galway H91 TK33, Ireland
[6] Taipei Med Univ, Wan Fang Hosp, Dept Radiol, Taipei, Taiwan
[7] Our Ladys Univ Hosp, Dept Rheumatol, Manorhamilton, Ireland
[8] Sligo Univ Hosp, Dept Geriatr Med, Sligo, Ireland
[9] Natl Univ Ireland, Sch Comp Sci, Galway, Ireland
关键词
data analysis framework; disease prediction; healthcare big data; health information prediction system; osteoporosis;
D O I
暂无
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Osteoporotic fractures are a major and growing public health problem, which is strongly associated with other illnesses and multi-morbidity. Big data analytics has the potential to improve care for osteoporotic fractures and other non-communicable diseases (NCDs), reduces healthcare costs and improves healthcare decision-making for patients with multi-disorders. However, robust and comprehensive utilization of healthcare big data in osteoporosis care practice remains unsatisfactory. In this paper, we present a conceptual design of an intelligent analytics system, namely, the dual X-ray absorptiometry (DXA) health informatics prediction (HIP) system, for healthcare big data research and development. Comprising data source, extraction, transformation, loading, modelling and application, the DXA HIP system was applied in an osteoporosis healthcare context for fracture risk prediction and the investigation of multi-morbidity risk. Data was sourced from four DXA machines located in three healthcare centres in Ireland. The DXA HIP system is novel within the Irish context as it enables the study of fracture-related issues in a larger and more representative Irish population than previous studies. We propose this system is applicable to investigate other NCDs which have the potential to improve the overall quality of patient care and substantially reduce the burden and cost of all NCDs.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Conceptual design of the dual X-ray absorptiometry health informatics prediction system for osteoporosis care
    Erjiang, E.
    Carey, John J.
    Wang, Tingyan
    Yang, Lan
    Chan, Wing P.
    Whelan, Bryan
    Silke, Carmel
    O'Sullivan, Miriam
    Rooney, Bridie
    McPartland, Aoife
    O'Malley, Grainne
    Brennan, Attracta
    Yu, Ming
    Dempsey, Mary
    HEALTH INFORMATICS JOURNAL, 2022, 28 (01)
  • [2] Prevalence of Low Bone Mass and Osteoporosis in Ireland: the Dual-Energy X-Ray Absorptiometry (DXA) Health Informatics Prediction (HIP) Project
    Carey, John J.
    Erjiang, E.
    Wang, Tingyan
    Yang, Lan
    Dempsey, Mary
    Brennan, Attracta
    Yu, Ming
    Chan, Wing P.
    Whelan, Bryan
    Silke, Carmel
    O'Sullivan, Miriam
    Rooney, Bridie
    McPartland, Aoife
    O'Malley, Grainne
    JBMR PLUS, 2023, 7 (10)
  • [3] Detection of osteoporosis by dual energy X-ray absorptiometry
    Makhdoom, Asadullah
    Rahopoto, Muhammad Qasim
    Siddiqui, Khaleeque Ahmed
    Qureshi, Ghulam Ali
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (06) : 1265 - 1269
  • [4] Utility of dual X-ray absorptiometry and single X-ray absorptiometry as diagnostic tools for involutional osteoporosis
    T. Inoue
    K. Yamazaki
    K. Kushida
    Osteoporosis International, 1997, 7 : 117 - 119
  • [5] Why dual X-ray absorptiometry is the gold standard in diagnosing osteoporosis
    Jelic, Dorde
    Stefanovic, Dara
    Petronijevic, Milan
    Jelic, Marina Andelic
    VOJNOSANITETSKI PREGLED, 2008, 65 (12) : 919 - 922
  • [6] The usefulness of dual energy X-ray and laser absorptiometry of the calcaneus versus dual energy X-ray absorptiometry of hip and spine in diagnosing manifest osteoporosis
    de Klerk, Gijs
    van der Velde, D.
    van der Palen, J.
    van Bergeijk, L.
    Hegeman, J. H.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (02) : 251 - 257
  • [7] The usefulness of dual energy X-ray and laser absorptiometry of the calcaneus versus dual energy X-ray absorptiometry of hip and spine in diagnosing manifest osteoporosis
    Gijs de Klerk
    D. van der Velde
    J. van der Palen
    L. van Bergeijk
    J. H. Hegeman
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 251 - 257
  • [8] Comparison of Phalangeal Absorptiometry Technique with Dual Energy X-Ray Absorptiometry Technique in the Diagnosis of Osteoporosis
    Huner, Berrin
    Ozguzel, Mehmet Hayri
    Atar, Sevgi
    TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 55 (02): : 68 - 72
  • [9] Dual Energy X-ray Absorptiometry Scanning for Osteoporosis Detection: Analysis of Patients at a Tertiary Care Hospital
    Nisar, Aamer
    Hamza, Hafiz Muhammad
    Awan, Ayaz A.
    Malik, Muiz M.
    Gondal, Abdullah
    Riaz, Mehwish
    Bhatti, Hamza Z.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [10] The role of quantitative ultrasound in predicting osteoporosis defined by dual X-ray absorptiometry
    Çetin, A
    Ertürk, H
    Çeliker, R
    Sivri, A
    Hasçelik, Z
    RHEUMATOLOGY INTERNATIONAL, 2001, 20 (02) : 55 - 59