MEASUREMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION IN SHEEP WITH AN AMPEROMETRIC ENZYME ELECTRODE

被引:0
|
作者
KERNER, W [1 ]
ZIER, H [1 ]
STEINBACH, G [1 ]
HAAS, J [1 ]
WARHADPANDE, R [1 ]
BRUCKEL, J [1 ]
PFEIFFER, EF [1 ]
机构
[1] UNIV ULM,DEPT INTERNAL MED 1,D-7900 ULM,FED REP GER
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:A539 / A539
页数:1
相关论文
共 50 条
  • [1] MEASUREMENT OF THE SUBCUTANEOUS GLUCOSE-CONCENTRATION
    SCHMIDT, FJ
    DIABETES CARE, 1993, 16 (12) : 1627 - 1628
  • [2] MEASUREMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION
    MEYERHOFF, C
    STERNBERG, F
    BISCHOF, F
    MENNEL, FJ
    PFEIFFER, EF
    DIABETES CARE, 1993, 16 (12) : 1626 - 1627
  • [3] THE AMPEROMETRIC ESTIMATION OF INTERSTITIAL GLUCOSE-CONCENTRATION - HOW TO INTERPRET THE ELECTRODE SIGNAL
    ABEL, P
    FISCHER, U
    SALZSIEDER, E
    BRUNSTEIN, E
    DIABETOLOGIA, 1987, 30 (07) : A492 - A492
  • [4] CONTINUOUSLY MONITORED SUBCUTANEOUS GLUCOSE-CONCENTRATION BY USING IMPLANTED ENZYME ELECTRODES
    MULLER, A
    ABEL, P
    FISCHER, U
    BIOMEDICA BIOCHIMICA ACTA, 1986, 45 (06) : 769 - 777
  • [5] A POTENTIALLY IMPLANTABLE ENZYME ELECTRODE FOR AMPEROMETRIC MEASUREMENT OF GLUCOSE
    KERNER, W
    ZIER, H
    STEINBACH, G
    BRUCKEL, J
    PFEIFFER, EF
    WEISS, T
    CAMMANN, K
    PLANCK, H
    HORMONE AND METABOLIC RESEARCH, 1988, 20 : 8 - 13
  • [6] MEASUREMENT OF GLUCOSE-CONCENTRATION IN THE PRESENCE OF COREACTANTS WITH A PLATINUM-ELECTRODE
    LERNER, H
    SOELDNER, JS
    COLTON, CK
    GINER, J
    DIABETES CARE, 1982, 5 (03) : 229 - 237
  • [7] POTENTIOMETRIC MEASUREMENT OF GLUCOSE-CONCENTRATION WITH AN IMMOBILIZED GLUCOSE-OXIDASE CATALASE ELECTRODE
    WINGARD, LB
    LIU, CC
    WOLFSON, SK
    YAO, SJ
    DRASH, AL
    DIABETES CARE, 1982, 5 (03) : 199 - 202
  • [8] CONTINUOUS GLUCOSE MONITORING IN SUBCUTANEOUS TISSUE AND BLOOD WITH AN AMPEROMETRIC ENZYME ELECTRODE
    BRUCKEL, J
    ZIER, H
    KERNER, W
    PFEIFFER, EF
    BIOSENSORS : APPLICATIONS IN MEDICINE, ENVIRONMENTAL PROTECTION AND PROCESS CONTROL, 1989, 13 : 89 - 91
  • [9] QUANTITATION OF GLUCOSE-CONCENTRATION USING A GLUCOSE OXIDASE CATALASE ELECTRODE BY POTENTIOMETRIC MEASUREMENT
    LIU, CC
    WINGARD, LB
    WOLFSON, SK
    YAO, SJ
    DRASH, AL
    SCHILLER, JG
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1979, 6 (01): : 19 - 26
  • [10] GLUCOSE-CONCENTRATION IN SUBCUTANEOUS EXTRACELLULAR-SPACE
    SCHMIDT, FJ
    SLUITER, WJ
    SCHOONEN, AJM
    DIABETES CARE, 1993, 16 (05) : 695 - 700