HEMODIALYZER PERFORMANCE - BIOLOGICAL INDEXES

被引:12
作者
HOLMES, CJ
机构
[1] Baxter Healthcare, Renal Division, Illinois, McGaw Park
关键词
HEMODIALYSIS; BIOCOMPATIBILITY;
D O I
10.1111/j.1525-1594.1995.tb02274.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the last decade there has been a rapid increase in the number of biological indices that could potentially be used as measures of hemodialyzer or membrane biocompatibility. Consequently, it has become more challenging for all of those involved in renal replacement therapy to evaluate the relative merits of one membrane versus another when faced with their ever increasing variety of parameters. This review attempts to summarize the current array of biological parameters described in the literature as indices of biocompatibility and provide a critique of their utility. Emphasis is placed on measures of activation of the plasma cascade systems, complement, coagulation, and kinin as primary indices of biocompatibility. Additional information on neutrophil, monocyte, platelet, lymphocyte and natural killer (NK) cell effects may provide further insight into blood-membrane mediated interactions although many of these may parallel plasma cascade systems activation. The importance of good statistical design and analysis is emphasized to ensure meaningful interpretation of any study.
引用
收藏
页码:1126 / 1135
页数:10
相关论文
共 61 条
[1]   INVIVO T-CELL PREACTIVATION IN CHRONIC UREMIC HEMODIALYZED AND NON-HEMODIALYZED PATIENTS [J].
BEAURAIN, G ;
NARET, C ;
MARCON, L ;
GRATEAU, G ;
DRUEKE, T ;
URENA, P ;
NELSON, DL ;
BACH, JF ;
CHATENOUD, L .
KIDNEY INTERNATIONAL, 1989, 36 (04) :636-644
[2]   DIFFERENTIAL ACTIVATION OF MONOCYTES IN HEMODIALYSIS-PATIENTS EXPOSED TO DIFFERENT TYPES OF MEMBRANES [J].
BLUMENSTEIN, M ;
ZIEGLERHEITBROCK, HWL ;
SCHILLER, B ;
SCHMIDT, B ;
WARD, RA ;
GURLAND, HJ .
SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1990, 31 (02) :183-190
[3]  
CARUANA RJ, 1992, INT J ARTIF ORGANS, V15, P493
[4]  
CASES A, 1993, KIDNEY INT, V43, pS217
[5]   ANAPHYLATOXIN FORMATION DURING HEMODIALYSIS - COMPARISON OF NEW AND RE-USED DIALYZERS [J].
CHENOWETH, DE ;
CHEUNG, AK ;
WARD, DM ;
HENDERSON, LW .
KIDNEY INTERNATIONAL, 1983, 24 (06) :770-774
[6]  
CHEUNG AK, 1994, J AM SOC NEPHROL, V5, P110
[7]   ACTIVATION OF COMPLEMENT BY HEMODIALYSIS MEMBRANES - POLYACRYLONITRILE BINDS MORE C3A THAN CUPROPHAN [J].
CHEUNG, AK ;
PARKER, CJ ;
WILCOX, LA ;
JANATOVA, J .
KIDNEY INTERNATIONAL, 1990, 37 (04) :1055-1059
[8]   ACTIVATION OF THE ALTERNATIVE PATHWAY OF COMPLEMENT BY CELLULOSIC HEMODIALYSIS MEMBRANES [J].
CHEUNG, AK ;
PARKER, CJ ;
WILCOX, L ;
JANATOVA, J .
KIDNEY INTERNATIONAL, 1989, 36 (02) :257-265
[9]  
COLLINS DM, 1993, J AM SOC NEPHROL, V4, P148
[10]   GRANULOCYTE ACTIVATION AND ADHESION MOLECULES DURING HEMODIALYSIS WITH CUPROPHANE AND A HIGH-FLUX BIOCOMPATIBLE MEMBRANE [J].
COMBE, C ;
POURTEIN, M ;
DEPRECIGOUT, V ;
BAQUEY, A ;
MOREL, D ;
POTAUX, L ;
VINCENDEAU, P ;
BEZIAN, JH ;
APARICIO, M .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (03) :437-442