Accuracy of various imaging methods for detecting misfit at the tooth-restoration interface in posterior teeth

被引:5
作者
Francio, Luciano Andrei [1 ]
Silva, Fernanda Evangelista [2 ]
Valerio, Claudia Scigliano [2 ]
Assuncao e Alves Cardoso, Claudia [2 ]
Jansen, Wellington Correa [3 ]
Manzi, Flavio Ricardo [2 ]
机构
[1] Univ Tuiuti Parana, Dept Dent, Curitiba, Parana, Brazil
[2] Pontificia Univ Catolica Minas Gerais, Dept Oral Radiol, Belo Horizonte, MG, Brazil
[3] Pontificia Univ Catolica Minas Gerais, Dept Dent, Belo Horizonte, MG, Brazil
关键词
Biomedical and Dental Materials; Cone-Beam Computed Tomography; Digital Radiography; X-ray diagnosis;
D O I
10.5624/isd.2018.48.2.87
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The present study aimed to evaluate which of the following imaging methods best assessed misfit at the tooth-restoration interface: (1) bitewing radiographs, both conventional and digital, performed using a photostimulable phosphor plate (PSP) and a charge-coupled device (CCD) system; (2) panoramic radiographs, both conventional and digital; and (3) cone-beam computed tomography (CBCT). Materials and Methods: Forty healthy human molars with class I cavities were selected and divided into 4 groups according to the restoration that was applied: composite resin, composite resin with liner material to simulate misfit, dental amalgam, and dental amalgam with liner material to simulate misfit. Radiography and tomography were performed using the various imaging methods, and the resulting images were analyzed by 2 calibrated radiologists. The true presence or absence of misfit corresponding to an area of radiolucency in regions subjacent to the esthetic and metal restorations was validated with microscopy. The data were analyzed using a receiver operating characteristic (ROC) curve, and the scores were compared using the Cohen kappa coefficient. Results: For bitewing images, the digital systems (CCD and PSP) showed a higher area under the ROC curve (AUROC) for the evaluation of resin restorations, while the conventional images exhibited a larger AUROC for the evaluation of amalgam restorations. Conventional and digital panoramic radiographs did not yield good results for the evaluation of resin and amalgam restorations (P < .05). CBCT images exhibited good results for resin restorations (P> .05), but showed no discriminatory ability for amalgam restorations (P < .05). Conclusion: Bitewing radiographs (conventional or digital) should be the method of choice when assessing dental restoration misfit.
引用
收藏
页码:87 / 96
页数:10
相关论文
共 25 条
[1]  
Belem MD, 2013, DENTOMAXILLOFAC RAD, V42, P2012
[2]   Comparative evaluation among different materials to replace soft tissue in oral radiology studies [J].
Caldas, Maria de Paula ;
de Moraes Ramos-Perez, Flavia Maria ;
de Almeida, Solange Maria ;
Haiter-Neto, Francisco .
JOURNAL OF APPLIED ORAL SCIENCE, 2010, 18 (03) :264-267
[3]   A comparison of 18 different x-ray detectors currently used in dentistry [J].
Farman, AG ;
Farman, TT .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 99 (04) :485-489
[4]   Detection of non-cavitated approximal caries lesions in digital images from seven solid-state receptors with particular focus on task-specific enhancement filters. An ex vivo study in human teeth [J].
Haiter-Neto, Francisco ;
dos Anjos Pontual, Andrea ;
Frydenberg, Morten ;
Wenzel, Ann .
CLINICAL ORAL INVESTIGATIONS, 2008, 12 (03) :217-223
[5]   Detection of Vertical Root Fractures in Endodontically Treated Teeth by a Cone Beam Computed Tomography Scan [J].
Hassan, Bassam ;
Metska, Maria Elissavet ;
Ozok, Ahmet Rifat ;
van der Stelt, Paul ;
Wesselink, Paul Rudolf .
JOURNAL OF ENDODONTICS, 2009, 35 (05) :719-722
[6]   Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography [J].
Kamburoglu, K. ;
Kolsuz, E. ;
Murat, S. ;
Yuksel, S. ;
Ozen, T. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (06) :450-459
[7]   Occlusal Caries Depth Measurements Obtained by Five Different Imaging Modalities [J].
Kamburoglu, Kivanc ;
Kurt, Hakan ;
Kolsuz, Eray ;
Oztas, Bengi ;
Tatar, Ilkan ;
Celik, Hakan Hamdi .
JOURNAL OF DIGITAL IMAGING, 2011, 24 (05) :804-813
[8]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[9]   Radiographic diagnosis of dental restoration misfit: a systematic review [J].
Liedke, G. S. y ;
Spin-Neto, R. ;
da Silveira, H. E. D. ;
Wenzel, A. .
JOURNAL OF ORAL REHABILITATION, 2014, 41 (12) :957-967
[10]   Diagnostic accuracy of cone beam computed tomography sections with various thicknesses for detecting misfit between the tooth and restoration in metal-restored teeth [J].
Liedke, Gabriela Salatino ;
Spin-Neto, Rubens ;
Vizzotto, Mariana Boessio ;
da Silveira, Priscila Fernanda ;
Wenzel, Ann ;
Dias da Silveira, Heloisa Emilia .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (02) :E131-E137