INFLAMMATORY ARTHRITIS AFTER FAILURE OF SILICONE-RUBBER REPLACEMENT OF THE RADIAL HEAD

被引:81
作者
VANDERWILDE, RS [1 ]
MORREY, BF [1 ]
MELBERG, MW [1 ]
VINH, TN [1 ]
机构
[1] MAYO CLIN & MAYO FDN,DEPT ORTHOPAED,ROCHESTER,MN 55905
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1994年 / 76B卷 / 01期
关键词
D O I
10.1302/0301-620X.76B1.8300687
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The management of radial head fractures complicated by ligamentous disruption remains a matter of controversy. The use of a silicone radial head implant to provide temporary stability is thought to help to protect the ligaments during healing. The reported complications of long-term implantation of a silicone replacement include fracture, dislocation, synovitis, lymphadenitis and subchondral resorption. We now report one case in which an inflammatory process resulted in generalised cartilage degeneration. This has not previously been noted.