ELECTRICAL-IMPEDANCE TOMOGRAPHY WITH CORTICAL OR SCALP ELECTRODES DURING GLOBAL CEREBRAL-ISCHEMIA IN THE ANESTHETIZED RAT

被引:34
作者
HOLDER, DS
机构
[1] Dept. of Physiol., Univ. Coll., London
来源
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT | 1992年 / 13卷 / 01期
关键词
D O I
10.1088/0143-0815/13/1/008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The performance of a prototype impedance imaging (Electrical Impedance Tomography, EIT) system using cortical or scalp electrodes has been assessed in a model of global cerebral ischaemia in the anaesthetised rat. In preliminary calibration experiments using a circular array of electrodes around a tank of saline, the centre of a polythene rod could be localised with a mean error of 4% of the tank diameter, and two such rods could be discriminated when separated by 22% of the tank diameter. Cerebral ischaemia was produced by diathermy of the vertebral arteries and reversible occlusion of the common carotid arteries for 15 min. A bimodal impedance increase of about 50 - 200% was recorded with a ring of cortical electrodes in the fronto-occipital plane. With a similarly orientated ring of scalp electrodes, a unimodal impedance increase of about 10% was observed. In both cases, impedance reversed after cerebral reperfusion. Similar but irreversible changes were observed post mortem. As the reconstruction algorithm assumes constant initial resistivity, this suggests that modifications to allow for initial conditions would be needed for more accurate imaging with scalp electrodes.
引用
收藏
页码:87 / 98
页数:12
相关论文
共 15 条
[1]  
Barber D C, 1987, Clin Phys Physiol Meas, V8 Suppl A, P47, DOI 10.1088/0143-0815/8/4A/006
[2]  
Brown B H, 1987, Clin Phys Physiol Meas, V8 Suppl A, P91, DOI 10.1088/0143-0815/8/4A/012
[3]  
EYUBOGLU BM, 1989, P IEEE EMBS C SEATTL, P442
[4]   CEREBRAL-ISCHEMIA PRODUCED BY 4-VESSEL OCCLUSION IN THE RAT - A QUANTITATIVE-EVALUATION OF CEREBRAL BLOOD-FLOW [J].
FURLOW, TW .
STROKE, 1982, 13 (06) :852-855
[5]   DETECTION OF CEREBRAL-ISCHEMIA IN THE ANESTHETIZED RAT BY IMPEDANCE MEASUREMENT WITH SCALP ELECTRODES - IMPLICATIONS FOR NONINVASIVE IMAGING OF STROKE BY ELECTRICAL-IMPEDANCE TOMOGRAPHY [J].
HOLDER, DS .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 (01) :63-75
[6]   DETECTION OF CORTICAL SPREADING DEPRESSION IN THE ANESTHETIZED RAT BY IMPEDANCE MEASUREMENT WITH SCALP ELECTRODES - IMPLICATIONS FOR NONINVASIVE IMAGING OF THE BRAIN WITH ELECTRICAL-IMPEDANCE TOMOGRAPHY [J].
HOLDER, DS .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 (01) :77-86
[7]  
JORGENSEN MB, 1982, ACTA NEUROL SCAND, V66, P536
[8]  
MCARDLE FJ, 1989, 11TH P IEEE ENG MED, P480
[9]  
Murphy D, 1987, Clin Phys Physiol Meas, V8 Suppl A, P131, DOI 10.1088/0143-0815/8/4A/017
[10]   NEW MODEL OF BILATERAL HEMISPHERIC ISCHEMIA IN THE UNANESTHETIZED RAT [J].
PULSINELLI, WA ;
BRIERLEY, JB .
STROKE, 1979, 10 (03) :267-272