MEASUREMENT OF ELASTIC RESISTING FORCES OF INTRAOCULAR HAPTIC LOOPS OF VARYING GEOMETRICAL DESIGNS AND MATERIAL COMPOSITION

被引:21
作者
GUTHOFF, R
ABRAMO, F
DRAEGER, J
CHUMBLEY, L
机构
关键词
dynamometry; elastic force; haptic loop; intraocular lens; poly(methyl methacrylate); poly-HEMA; polypropylene; silicone; stiffness; vector analysis;
D O I
10.1016/S0886-3350(13)80768-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The relationship between experimentally induced intraocular lens (IOL) haptic deformation and resulting elastic haptic counter-resisting forces measured by electronic dynamometry was examined for 34 different IOL haptics of varying material composition and geometrical designs. Poly(methyl methacrylate) (PMMA) and polypropylene loops of similar geometry did not fundamentally differ from one another, although lenses of differing geometry behaved differently. Unlike PMMA and polypropylene loops, soft haptics of poly-HEMA and silicone rubber demonstrated a larger elastic resistance force to the same degree of deformation. This was based upon design characteristics of the lenses and not upon intrinsic properties of the materials, which would have produced the opposite result. By comparative analysis of these dynamometer measurements and considerations of the lens design and elastic properties (including memory) of the component materials, we can calculate the stresses upon the zonular and capsular bag structures during and after IOL implantation. © 1990, American Society of Cataract and Refractive Surgery. All rights reserved.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 30 条
[1]  
McDonnell PJ, Zarbin MA, Green WR, Posterior capsule opacification in pseudophakic eyes, Ophthalmology, 90, pp. 1548-1553, (1983)
[2]  
McDonnell PJ, Patel A, Green WR, Comparison of intracapsular and extracapsular cataract surgery
[3]  
histopathologic study of eyes obtained postmortem, Ophthalmology, 92, pp. 1208-1225, (1985)
[4]  
McDonnell PJ, Champion R, Green WR, Location and composition of haptics of posterior chamber intraocular lenses
[5]  
histopathologic study of postmortem eyes, Ophthalmology, 94, pp. 136-142, (1987)
[6]  
Champion R, McDonnell PJ, Green WR, Intraocular lenses. Histopathologic characteristics of a large series of autopsy eyes, Surv Ophthalmol, 30, pp. 1-32, (1985)
[7]  
Apple DJ, Reidy JJ, Googe JM, Et al., A comparison of ciliary sulcus and capsular bag fixation of posterior chamber intraocular lenses, Am Intra-Ocular Implant Soc J, 11, pp. 44-63, (1985)
[8]  
Boke W, Intraokulare Entzundungsreaktionen nach Implantation einer retropupillaren Linse, Klin Monatsbl Augenheilkd, 190, pp. 393-402, (1987)
[9]  
Crawford JB, A histopathologic study of the position of the Shearing intraocular lens in the posterior chamber, Am J Ophthalmol, 91, pp. 458-461, (1981)
[10]  
Binkhorst CD, Safe all-in-the-bag pseudophakia with a new lens design (the moustache lens), Doe Ophthalmol, 59, pp. 57-69, (1985)