PROGRAMMED-TEMPERATURE INJECTOR FOR LARGE-VOLUME SAMPLE INTRODUCTION IN CAPILLARY GAS-CHROMATOGRAPHY AND FOR LIQUID-CHROMATOGRAPHY GAS-CHROMATOGRAPHY INTERFACING

被引:45
作者
STANIEWSKI, J
JANSSEN, HG
CRAMERS, CA
RIJKS, JA
机构
[1] Eindhoven University of Technology, Faculty of chemical Engineering, Laboratory of Instrumental Analysis, Eindhoven, 5600 MB
关键词
PROGRAMMED-TEMPERATURE SAMPLE INTRODUCTION; PTV INJECTOR; LARGE VOLUME INJECTION; ONLINE LC-GC INTERFACING; WATER ANALYSIS;
D O I
10.1002/mcs.1220040407
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The introduction of large sample volumes in capillary gas chromatography is becoming increasingly important in various application areas. Especially in the analysis of very dilute samples (e.g., environmental samples) and in coupled LC-GC, large volume sampling is extremely important. Programmed-temperature sample introduction is shown to be an attractive technique for these purposes. In this paper we present some applications of large volume sampling in environmental analysis. Water samples were analyzed using both off-line and on-line extraction with gas chromatography (GC) analysis. In the off-line method, pollutants were extracted into hexane or methylene chloride. Using the programmed-temperature injector, up to 250-mu-L of the extract could be introduced into the GC system. In this way, reproducible quantitative analyses of PAHs and herbicides were achieved at sub-ppb concentrations using flame ionization detection. In the on-line mode, pollutants were preconcentrated on a short liquid chromatography (LC) column packed with a PLRP-S solid phase extraction material. After the trapping step, the components were desorbed by ethyl acetate and transferred directly into the programmed-temperature vaporizer (PTV-GC system. Using this method, detection limits below about 1 ppb of herbicides in water were obtained.
引用
收藏
页码:331 / 338
页数:8
相关论文
共 50 条
[21]   Role of the retaining precolumn in large-volume on-column injections of volatiles to gas chromatography [J].
Kristenson, EM ;
Kamminga, DA ;
Catalina, MI ;
Espiga, C ;
Vreuls, RJJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :95-104
[22]   USE OF OPEN-TUBULAR TRAPPING COLUMNS FOR ONLINE EXTRACTION CAPILLARY GAS-CHROMATOGRAPHY OF AQUEOUS SAMPLES [J].
MOL, HGJ ;
JANSSEN, HG ;
CRAMERS, CA .
HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1993, 16 (07) :413-418
[23]   Detectability enhancement by the use of large-volume injections in gas chromatography cryotrapping Fourier transform infrared spectrometry [J].
Hankemeier, T ;
vanderLaan, HTC ;
Vreuls, JJ ;
Vredenbregt, MJ ;
Visser, T ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1996, 732 (01) :75-84
[24]   Temperature-programmed packed capillary liquid chromatography separation with large volume on-column focusing of retinyl esters [J].
Molander, P ;
Thommesen, SJ ;
Bruheim, IA ;
Trones, R ;
Greibrokk, T ;
Lundanes, E ;
Gundersen, TE .
HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (09) :490-494
[25]   A new cleanup method of dioxins in sediment using large volume injection gas chromatography online coupled with liquid chromatography [J].
Tang, Fengmei ;
Ni, Yuwen ;
Zhang, Haijun ;
Li, Yun ;
Jin, Jing ;
Wang, Longxing ;
Chen, Jiping .
ANALYTICA CHIMICA ACTA, 2012, 729 :73-79
[26]   Separation of ceramides by sub-ambient temperature-assisted large volume injection in temperature-programmed packed capillary liquid chromatography [J].
Molander, P ;
Holm, A ;
Lundanes, E ;
Greibrokk, T ;
Ommundsen, E .
HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (11) :653-655
[27]   Analysis of chlorophenoxy acid herbicides in water by large-volume on-line derivatization and gas chromatography-mass spectrometry [J].
Ding, WH ;
Liu, CH ;
Yeh, SP .
JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) :111-116
[28]   SPECIATION ANALYSIS OF ORGANOTIN IN THE RIVER SCHELDT BY CAPILLARY GAS-CHROMATOGRAPHY ATOMIC-EMISSION SPECTROMETRY (GC-AES) [J].
CEULEMANS, M ;
SZPUNARLOBINSKA, J ;
DIRKX, WMR ;
LOBINSKI, R ;
ADAMS, FC .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 52 (1-4) :113-125
[29]   Micro liquid-liquid extraction combined with large-volume injection gas chromatography-mass spectrometry for the determination of haloacetaldehydes in treated water [J].
Serrano, Maria ;
Silva, Manuel ;
Gallego, Mercedes .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (46) :8295-8302
[30]   Large-volume injections in capillary gas chromatography using a separately, heated packed pre-column: Application to mercury speciation in natural water [J].
Hanstrom, S ;
Briche, C ;
Emteborg, H ;
Baxter, DC .
ANALYST, 1996, 121 (11) :1657-1663