PERFORMANCE OF EVACUATED TUBE SOLAR COLLECTOR USING WATER-BASED TITANIUM OXIDE NANOFLUID

被引:90
|
作者
Mahendran, M. [1 ]
Lee, G. C. [1 ]
Sharma, K. V. [2 ]
Shahrani, A. [1 ]
Bakar, R. A. [1 ]
机构
[1] Univ Malaysia Pahang, Fac Mech Engn, Pekan 26600, Pahang, Malaysia
[2] Jawaharlal Nehru Technol Univ Hyderabad, Hyderabad 500085, Andhra Pradesh, India
关键词
Solar Energy; Nanofluid; Evacuated Tube Solar Collector;
D O I
10.15282/jmes.3.2012.6.0028
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Experiments are undertaken to determine the efficiency of an evacuated tube solar collector using water-based Titanium Oxide (TiO2) nanofluid at the Pekan Campus (3 degrees 32' N, 103 degrees 25'E), Faculty of Mechanical Engineering, University Malaysia Pahang, for the conversion of solar thermal energy. Malaysia lies in the equatorial zone with an average daily solar insolation of more than 900 W/m(2), which can reach a maximum of 1200 W/m(2) for most of the year. Traditionally water is pumped through the collector at an optimum flow rate, for the extraction of solar thermal energy. If the outlet temperature of the water is high, further circulation of the water through the collector is useless. This is due to the low thermal conductivity of water of 0.6 W/m.K compared to metals which is many orders higher. Hence it is necessary to reduce the surface temperature either by pumping water at a higher flow rate or by enhancing the fluid's properties by the dispersion of nanoparticles. Pumping water at higher flow rates is not advantageous as the overall efficiency of the system is lowered. Liquids in which nanosized particles of metal or their oxides are dispersed in a base liquid such as water are known as 'Nanofluids'. This results in higher values of thermal conductivity compared to the base liquid. The thermal conductivity increases with the concentration and temperature of the nanofluid. The increase in thermal conductivity with temperature is advantageous for application in collectors as the solar insolation varies throughout the day, with a minimum in the morning reaching a maximum at 2.00p.m and reducing thereafter. The efficiency of the collector estimated using a TiO2 nanofluid of 0.3% concentration is about 0.73, compared to water which is about 0.58. The efficiency is enhanced by 16.7% maximum with 30-50nm sized TiO2 nanoparticles dispersed in the water, compared to the system working solely with water. The flow rate is fixed at 2.7 liters per minute for both liquids.
引用
收藏
页码:301 / 310
页数:10
相关论文
共 50 条
  • [41] Improving performance of flat plate solar collector using nanofluid water/zinc oxide
    Shokrgozar Abbasi, Ali
    Khan, Aghaiy Naser
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (11) : 3391 - 3403
  • [42] Thermal Performance of Evacuated Tube Heat Pipe Solar Collector
    Putra, Nandy
    Kristian, M. R.
    David, R.
    Haliansyah, K.
    Ariantara, Bambang
    PROCEEDINGS OF THE 3RD AUN/SEED-NET REGIONAL CONFERENCE ON ENERGY ENGINEERING AND THE 7TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS (RCENE/THERMOFLUID 2015), 2016, 1737
  • [43] PERFORMANCE OF AN ACTIVE SOLAR STILL COUPLED TO EVACUATED TUBE COLLECTOR
    Sampathkumar, Karuppusamy
    Senthilkumar, Palanisamy
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2014, 13 (02): : 333 - 344
  • [44] Performance comparison of evacuated U-tube solar collector integrated parabolic reflector with conventional evacuated U-tube solar collector
    KIRAN NAIK, B.
    PREMNATH, S.
    MUTHUKUMAR, P.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2021, 46 (03):
  • [45] Turbulent flow analysis of a flattened tube in- plane curved solar collector using Titanium oxide nanofluid
    Sacithra, A.
    Manivannan, A.
    HEAT AND MASS TRANSFER, 2019, 55 (06) : 1783 - 1799
  • [46] Turbulent flow analysis of a flattened tube in- plane curved solar collector using Titanium oxide nanofluid
    A. Sacithra
    A. Manivannan
    Heat and Mass Transfer, 2019, 55 : 1783 - 1799
  • [47] Performance comparison of evacuated U-tube solar collector integrated parabolic reflector with conventional evacuated U-tube solar collector
    B KIRAN NAIK
    S PREMNATH
    P MUTHUKUMAR
    Sādhanā, 2021, 46
  • [48] Thermal performance of a solar cooker based on an evacuated tube solar collector with a PCM storage unit
    Sharma, SD
    Iwata, T
    Kitano, H
    Sagara, K
    SOLAR ENERGY, 2005, 78 (03) : 416 - 426
  • [49] Assessment of TiO2 water-based nanofluids with two distinct morphologies in a U type evacuated tube solar collector
    Hosseini, Seyed Mohammad Sadegh
    Dehaj, Mohammad Shafiey
    APPLIED THERMAL ENGINEERING, 2021, 182 (182)
  • [50] Performance evaluation of TiN/water nanofluid charged U-pipe evacuated tube solar thermal collector with twisted tape inserts
    Deshmukh, Kishor
    Kadam, Sunil
    Shirke, Makarand
    Nehe, Sandip
    Karmare, Suhas
    Galande, Swapnil
    HEAT AND MASS TRANSFER, 2025, 61 (01)