PERFORMANCE OF EVACUATED TUBE SOLAR COLLECTOR USING WATER-BASED TITANIUM OXIDE NANOFLUID

被引:90
作者
Mahendran, M. [1 ]
Lee, G. C. [1 ]
Sharma, K. V. [2 ]
Shahrani, A. [1 ]
Bakar, R. A. [1 ]
机构
[1] Univ Malaysia Pahang, Fac Mech Engn, Pekan 26600, Pahang, Malaysia
[2] Jawaharlal Nehru Technol Univ Hyderabad, Hyderabad 500085, Andhra Pradesh, India
关键词
Solar Energy; Nanofluid; Evacuated Tube Solar Collector;
D O I
10.15282/jmes.3.2012.6.0028
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Experiments are undertaken to determine the efficiency of an evacuated tube solar collector using water-based Titanium Oxide (TiO2) nanofluid at the Pekan Campus (3 degrees 32' N, 103 degrees 25'E), Faculty of Mechanical Engineering, University Malaysia Pahang, for the conversion of solar thermal energy. Malaysia lies in the equatorial zone with an average daily solar insolation of more than 900 W/m(2), which can reach a maximum of 1200 W/m(2) for most of the year. Traditionally water is pumped through the collector at an optimum flow rate, for the extraction of solar thermal energy. If the outlet temperature of the water is high, further circulation of the water through the collector is useless. This is due to the low thermal conductivity of water of 0.6 W/m.K compared to metals which is many orders higher. Hence it is necessary to reduce the surface temperature either by pumping water at a higher flow rate or by enhancing the fluid's properties by the dispersion of nanoparticles. Pumping water at higher flow rates is not advantageous as the overall efficiency of the system is lowered. Liquids in which nanosized particles of metal or their oxides are dispersed in a base liquid such as water are known as 'Nanofluids'. This results in higher values of thermal conductivity compared to the base liquid. The thermal conductivity increases with the concentration and temperature of the nanofluid. The increase in thermal conductivity with temperature is advantageous for application in collectors as the solar insolation varies throughout the day, with a minimum in the morning reaching a maximum at 2.00p.m and reducing thereafter. The efficiency of the collector estimated using a TiO2 nanofluid of 0.3% concentration is about 0.73, compared to water which is about 0.58. The efficiency is enhanced by 16.7% maximum with 30-50nm sized TiO2 nanoparticles dispersed in the water, compared to the system working solely with water. The flow rate is fixed at 2.7 liters per minute for both liquids.
引用
收藏
页码:301 / 310
页数:10
相关论文
共 50 条
  • [21] Performance improvement of a heat pipe evacuated solar water collector using quartz/water nanofluid: A numerical and experimental study
    Aytac, Ipek
    Khanlari, Ataollah
    Tuncer, Azim Dogus
    Variyenli, Halil Ibrahim
    Unvar, Sinan
    RENEWABLE ENERGY, 2024, 236
  • [22] Solar thermal energy performance on mono/ trihybrid nanofluid flow through the evacuated thermal collector tube
    Rathore, Niraj
    Sandeep, N.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (94) : 36883 - 36899
  • [23] Comparative analysis of eccentric evacuated tube solar collector with circular and rectangular absorber working with nanofluid
    Ismail, Kamal A. R.
    Teles, Mavd P. R.
    Lino, Fatima A. M.
    CLEANER ENGINEERING AND TECHNOLOGY, 2021, 3
  • [24] Thermal performance of an open thermosyphon using nanofluid for evacuated tubular high temperature air solar collector
    Liu, Zhen-Hua
    Hu, Ren-Lin
    Lu, Lin
    Zhao, Feng
    Xiao, Hong-shen
    ENERGY CONVERSION AND MANAGEMENT, 2013, 73 : 135 - 143
  • [25] Failure Investigation of Evacuated Tube Solar Collector of Water Heater
    Siddharaj V. Kumbhar
    Journal of Failure Analysis and Prevention, 2019, 19 : 1202 - 1206
  • [26] Evaluation of a micro-particle-enhanced phase-change material integrated heat pipe evacuated tube solar collector system using lanthanum oxide/water nanofluid
    Bhalavi, Jyoti
    Soni, Sanjay
    Gupta, Bhupendra
    Chauhan, Om Prakash
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 117 - 145
  • [27] Failure Investigation of Evacuated Tube Solar Collector of Water Heater
    Kumbhar, Siddharaj V.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2019, 19 (05) : 1202 - 1206
  • [28] Turbulent flow analysis of a flattened tube in- plane curved solar collector using Titanium oxide nanofluid
    A. Sacithra
    A. Manivannan
    Heat and Mass Transfer, 2019, 55 : 1783 - 1799
  • [29] Turbulent flow analysis of a flattened tube in- plane curved solar collector using Titanium oxide nanofluid
    Sacithra, A.
    Manivannan, A.
    HEAT AND MASS TRANSFER, 2019, 55 (06) : 1783 - 1799
  • [30] Performance evaluation of evacuated tube solar collector using Al2O3/ water nanofluid: Experiment, modelling, life cycle and cost analysis in the UAE context
    Rahman, Shek
    Said, Zafar
    Issa, Salah
    Assad, Mamdouh El Haj
    Sharma, Prabhakar
    Hachicha, Ahmed Amine
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2025, 76