共 33 条
Response reduction factor R evaluation for soft story reinforced concrete buildings
被引:0
作者:
Cerda, Pedro
[1
]
Rivero, Pedro
[2
]
Lobo-Quintero, William
[2
]
机构:
[1] Univ Ctr Occidental Lisandro Alvarado, Barquisimeto, Venezuela
[2] Univ Los Andes, Fac Ingn, Dept Estruct, Merida, Venezuela
来源:
CIENCIA E INGENIERIA
|
2006年
/
27卷
/
02期
关键词:
Soft story;
nonlinear analysis;
reduction factor;
D O I:
暂无
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
In the Venezuelan Code Covenin 1756-2001 "Edificaciones Sismorresistentes", the analysis of soft-story buildings is carried out considering a response factor R, but recommends that the solicitations are multiplied for 1.30. In this paper this recommendation is evaluated, considering structural models in 3D with soft-story located in different heights. A response reduction factor R=6 is considered without to increase the design solicitations. Twelve reinforced concrete buildings are analyzed: 4 of 6-floor levels, 4 of 12-floor levels and 4 of 18-floor levels. Basic buildings of same heights and others with soft-story applied in inferior, intermediate and superior level are considered. The behavior of each structure and the influence of soft-story in the global response are analyzed, with static and the dynamic nonlinear methods and three different accelerograms: two real and one simulated. The results averages indicate that in 6-floor levels buildings the response factor R is 0.71 times that of COVENIN code, for 12 is 0.73 and 18-floor levels is 0.60. The average is a factor equal to 0.68. Carrying out a good design is not necessary to affect the solicitations for a factor 1.3 indicated in the Code, and is preferable to reduce the factor R indicated in Covenin 1756: 2001. Other recommendations are made to contribute to the specification given by the Coven in Code 1756-2001.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 33 条