A RANDOMISED CONTROLLED TRIAL OF BUTTONHOLE CANNULATION FOR THE PREVENTION OF FISTULA ACCESS COMPLICATIONS

被引:73
作者
Chow, Josephine [1 ,2 ]
Rayment, Glenda [3 ]
Miguel, Susana San [3 ]
Gilbert, Margaret [3 ]
机构
[1] Sydney South West Area Hlth Serv, Area Cardiovasc Stream, Sydney, NSW, Australia
[2] Univ Sydney, Nursing Sch, Sydney, NSW, Australia
[3] Univ Tasmania, Nursing Sch, Hobart, Tas, Australia
关键词
Buttonhole cannulation; Cannulation technique; Dialysis access; Haemodialysis;
D O I
10.1111/j.1755-6686.2011.00211.x
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objectives: This multicentre, prospective, open label, randomised controlled trial was to determine whether buttonhole cannulation technique in new and established haemodialysis fistula reduced complications and prolonged the access life compared to usual practice. Method: Seventy subjects were recruited for this study. Subjects randomised to the buttonhole group had their fistula cannulated by the same staff member for two to four weeks at the same angle and direction with sharp needles. Once the tunnel was developed, blunt needles were used. The control group continued with usual practice (rope ladder rotation technique). Results: Infection at the cannulation site occurred in four patients in the buttonhole group and one in the rope ladder rotation group (p = 0.11). Haematomas at the cannulation site and site pain experienced during the dialysis session were more often recorded for the buttonhole group (p < 0.05). Conclusions: This study showed that buttonhole cannulation resulted more infections, haematoma formation and site pain during dialysis than with the rope ladder rotation group. A further larger scale longitudinal study is recommended.
引用
收藏
页码:85 / 93
页数:9
相关论文
共 14 条
[1]  
ANZDATA, 2008, ANZDATA REG AD AUSTR
[2]  
Ball LK, 2006, NEPHROL NURS J, V33, P299
[3]  
Cari, 2000, CAR AUSTR REN IMP VA
[4]  
Doss Sheila, 2008, Nephrol Nurs J, V35, P417
[5]  
Hays RD, 1997, MAN USE SCORING FREN
[6]  
KRONUNG G, 1984, DIALYSIS TRANSPLANT, V13, P635
[7]  
Marticorena Rosa M, 2006, Hemodial Int, V10, P193, DOI 10.1111/j.1542-4758.2006.00094.x
[8]   A simple method to create buttonhole cannulation tracks in a busy hemodialysis unit [J].
Marticorena, Rosa M. ;
Hunter, Joyce ;
Cook, Ramona ;
Kashani, Mina ;
Delacruz, Julia ;
Petershofer, Elizabeth ;
MacLeod, Steve ;
Dacouris, Niki ;
McFarlane, Philip A. ;
Donnelly, Sandra M. ;
Goldstein, Marc B. .
HEMODIALYSIS INTERNATIONAL, 2009, 13 (03) :316-321
[9]  
McCaffery Margo, 2002, Nursing, V32, P68
[10]   Hemodialysis vascular access: An ounce of prevention [J].
Schwab, SJ .