Effects of debonding of orthodontic brackets on topography and surface roughness of composite restorations

被引:0
作者
Moradi, Mina [1 ]
Hormozi, Elham [2 ]
Shamohammadi, Milad [3 ]
Rakhshan, Vahid [4 ]
机构
[1] North Khorasan Univ Med Sci, Sch Dent, Dept Orthodont, Bojnurd, Iran
[2] Isfahan Univ Med Sci, Sch Dent, Dept Orthodont, Esfahan, Iran
[3] Ahvaz Jundishapur Univ Med Sci, Sch Dent, Dept Orthodont, Ahvaz, Iran
[4] Azad Univ, Fac Dent, Dept Dent Anat, Tehran, Iran
关键词
Surface roughness; Composite restoration; Bracket debonding; Surface treatments; Profilometry;
D O I
10.1016/j.ortho.2018.09.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: To increase bond strength of brackets bonded to composite restorations, underlying composite restorations are usually roughened. This and subsequent bracket debonding might deteriorate smoothness of composite restoration, leading to clinical and aesthetic problems. Since this was not assessed before, this study was conducted. Methods: Seventy intact human premolars were collected and filled with composite restorations. They were randomly divided into 3 groups: control (n = 10), surface treatments before bracket bonding (bur, sandblasting, overall n = 40), and surface roughening without bracket bonding (bur, sandblasting, overall n = 20). The 40 specimens with bracket bonding steps were divided into two subgroups of with and without polishing after debonding of brackets (each n = 10). After aging the composites in two steps and treating surfaces according to abovementioned protocols, their surface topographies were evaluated under stereomicroscopy (80 x), scanning electron microscopy (using Zachrisson-Arthun index, at 500 x and 1000 x zooms), and by profilometry. Profilometry parameters and Zachrisson-Arthun index were statistically compared among different groups (alpha = 0.05, 0.005). Results: According to Kruskal-Wallis test, all profilometry parameters or the Zachrisson and Arthun index were significantly different between groups involving bracket debonding and control (P <= 0.001). Three-way ANOVA indicated that bracket debonding, polishing after debonding, and surface treatments before bracket bonding had a significant effect on Ra and Rz (P <= 0.05). Tukey post hoc test showed that bur and sandblasting methods were not significantly different (P > 0.05). Conclusion: Bur-roughening or sandblasting of composite surface before bonding brackets can increase surface roughness, while polishing can reduce it back to control levels. (C) 2018 CEO. Published by Elsevier Masson SAS. All rights reserved
引用
收藏
页码:623 / 637
页数:15
相关论文
共 50 条
  • [41] The effects of height and surface roughness of abutments and the type of cement on bond strength of cement-retained implant restorations
    Al Hamad, Khaled Q.
    Al Rashdan, Bashar A.
    Abu-Sitta, Ethar H.
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (06) : 638 - 644
  • [42] Carbamide peroxide bleaching agents: effects on surface roughness of enamel, composite and porcelain
    R. R. Moraes
    J. L. M. Marimon
    L. F. J. Schneider
    L. Correr Sobrinho
    G. B. Camacho
    M. Bueno
    Clinical Oral Investigations, 2006, 10 : 23 - 28
  • [43] Carbamide peroxide bleaching agents: Effects on surface roughness of enamel, composite and porcelain
    Moraes, RR
    Marimon, JLM
    Schneider, LFJ
    Sobrinho, LC
    Camacho, GB
    Bueno, M
    CLINICAL ORAL INVESTIGATIONS, 2006, 10 (01) : 23 - 28
  • [44] A Study of the Surface Topography and Roughness of Glazed and Unglazed Feldspathic Ceramics
    Mehulic, Ketij
    Svetlicic, Vesna
    Segota, Suzana
    Vojvodic, Denis
    Kovacic, Ivan
    Katanec, Davor
    Petricevic, Nikola
    Glavina, Domagoj
    Celebic, Asja
    COLLEGIUM ANTROPOLOGICUM, 2010, 34 : 235 - 238
  • [45] Modelling the combined effect of surface roughness and topography on bacterial attachment
    Chinnaraj, Subash Bommu
    Jayathilake, Pahala Gedara
    Dawson, Jack
    Ammar, Yasmine
    Portoles, Jose
    Jakubovics, Nicholas
    Chen, Jinju
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2021, 81 : 151 - 161
  • [46] Effectiveness of Porcelain Polishing Methods on the Roughness and Color Stability of CAD-CAM Ceramics after Orthodontic Bracket Debonding
    Haralur, Satheesh B.
    Shiban, Abdullah Saeed
    Alqahtani, Nasser Mohammed
    MATERIALS, 2023, 16 (14)
  • [47] Effects of alkaline etching on the surface roughness of a fibre-reinforced epoxy composite
    Roizard, X
    Wery, M
    Kirmann, J
    COMPOSITE STRUCTURES, 2002, 56 (03) : 223 - 228
  • [48] Bionic effects of nano hydroxyapatite dentifrice on demineralised surface of enamel post orthodontic debonding: in-vivo split mouth study
    Purva Verma
    Srirengalakshmi Muthuswamy Pandian
    Progress in Orthodontics, 22
  • [49] Bionic effects of nano hydroxyapatite dentifrice on demineralised surface of enamel post orthodontic debonding: in-vivo split mouth study
    Verma, Purva
    Muthuswamy Pandian, Srirengalakshmi
    PROGRESS IN ORTHODONTICS, 2021, 22 (01)
  • [50] Interfacial Effects of Surface Roughness and Topography on the Bond Strength of Silver-Sintered Joints on Copper Substrates
    Stegmann, Tamira
    Durst, Karsten
    Bruder, Enrico
    Gunst, Stefan
    Schwoebel, Andre
    JOURNAL OF ELECTRONIC MATERIALS, 2025, : 4143 - 4153