Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience

被引:1
作者
Gaba, Sahil [1 ,2 ]
Wahal, Naman [1 ,2 ]
Gautam, Deepak [1 ,2 ]
Pandit, Hemant [1 ,3 ]
Kumar, Vijay [1 ,2 ]
Malhotra, Rajesh [1 ]
机构
[1] All India Inst Med Sci, New Delhi, India
[2] All India Inst Med Sci, Dept Orthopaed, New Delhi, India
[3] Univ Leeds, Chapel Allerton Hosp, Leeds, W Yorkshire, England
来源
ARCHIVES OF BONE AND JOINT SURGERY-ABJS | 2018年 / 6卷 / 04期
关键词
Anteromedial osteoarthritis (AMOA); Microplasty instrumentation; Mobile bearing; Unicompartmental knee replacement (UKR);
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedial osteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement over phase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rate and improved component alignment. We report the results of UKR with the new instrumentation in a consecutive series with a minimum follow-up of 2 years. Methods: A prospective study of 115 cemented medial Oxford UKRs implanted in 89 patients was done. Postoperative alignment of the tibial and femoral components was analysed. Patient reported outcome measures were recorded using Oxford Knee Score (OKS) and the American Knee Society Score (KSS). Tegner Activity Scale (TAS) was used to record the activity level. Results: 115 consecutive medial Oxford UKRs were studied. All patients were followed up annually in this prospective ethically approved study. The mean follow-up was 36 months and the minimum follow-up was 25 months. No patient died and none were lost to follow-up. At the final follow-up, the average OKS of the cohort was 39.5 (SD: 5.7). 91.2 % of the patients had good or excellent OKS with only 3.5 % reporting poor OKS. The overall limb alignment was 4.8 degrees varus (0 - 14 degrees varus). Tibia was recut in 5.2 % of cases. Median bearing size was 3 (range: 3 to 6). There was one case of bearing dislocation and one case of aseptic tibial loosening. Conclusion: This is the first study to report results of MP instrumentation at a minimum follow-up of 2 years. Our study indicates that the new instrumentation results in reliable and accurate implantation of femoral and tibial components in majority of the cases, with a decrease in number of alignment outliers, and also a reduced rate of bearing dislocation.
引用
收藏
页码:301 / 311
页数:11
相关论文
共 24 条
[1]   Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up [J].
Berger, RA ;
Meneghini, RM ;
Jacobs, JJ ;
Sheinkop, MB ;
Della Valle, CJ ;
Rosenberg, AG ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05) :999-1006
[2]  
Goodfellow J, 2011, UNICOMPARTMENTAL ART, V2nd
[3]  
GOODFELLOW JW, 1986, CLIN ORTHOP RELAT R, P21
[4]   The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome [J].
Gulati, A. ;
Chau, R. ;
Pandit, H. G. ;
Gray, H. ;
Price, A. J. ;
Dodd, C. A. F. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (07) :896-902
[5]   Radiographic Comparison of Mobile-Bearing Partial Knee Single-Peg Versus Twin-Peg Design [J].
Hurst, Jason M. ;
Berend, Keith R. ;
Adams, Joanne B. ;
Lombardi, Adolph V., Jr. .
JOURNAL OF ARTHROPLASTY, 2015, 30 (03) :475-478
[6]   Mobile-bearing Unicondylar Knee Arthroplasty: The Oxford Experience [J].
Hurst, Jason M. ;
Berend, Keith R. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (01) :113-+
[7]   Impingement of the Mobile Bearing on the Lateral Wall of the Tibial Tray in Unicompartmental Knee Arthroplasty [J].
Inui, Hiroshi ;
Taketomi, Shuji ;
Yamagami, Ryota ;
Sanada, Takaki ;
Shirakawa, Nobuyuki ;
Tanaka, Sakae .
JOURNAL OF ARTHROPLASTY, 2016, 31 (07) :1459-1464
[8]   40 years of the Oxford Knee [J].
Jackson, W. F. M. ;
Berend, K. R. ;
Spruijt, S. .
BONE & JOINT JOURNAL, 2016, 98B :1-2
[9]   Does new instrumentation improve radiologic alignment of the Oxford® medial unicompartmental knee arthroplasty? [J].
Jang, Ki-Mo ;
Lim, Hong Chul ;
Han, Seung-Beom ;
Jeong, Chandong ;
Kim, Seul-Gi ;
Bae, Ji-Hoon .
KNEE, 2017, 24 (03) :641-650
[10]   Are the Oxford® medial unicompartmental knee arthroplasty new instruments reducing the bearing dislocation risk while improving components relationships? A case control study [J].
Koh, I. J. ;
Kim, J. H. ;
Jang, S. W. ;
Kim, M. S. ;
Kim, C. ;
In, Y. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (02) :183-187