A MICROSTRIP DETECTOR WITH DELAY-LINE READOUT

被引:1
|
作者
BARBOSA, AF [1 ]
RIEKEL, C [1 ]
WATTECAMPS, P [1 ]
机构
[1] CNPQ,CBPF,RIO DE JANEIRO,BRAZIL
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 01期
关键词
D O I
10.1063/1.1142685
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Principal limitations of position sensitive gasfilled detectors for x-ray synchrotron radiation applications are the counting rate and the positional resolution. Improvements in both areas are expected with microstrip technology. First results of a linear position sensitive microstrip detector with delay line readout are shown, and the possibility to achieve two-dimensional localization is evaluated.
引用
收藏
页码:667 / 669
页数:3
相关论文
共 50 条
  • [31] TESTS OF A TIME PROJECTION CHAMBER MODULE WITH DELAY-LINE READOUT
    BUDAGOV, YA
    GLAGOLEV, VV
    OMELYANENKO, AA
    SEMENOV, AA
    HLINKA, V
    POVINEC, P
    SITAR, B
    KLADIVA, E
    SEMAN, M
    SPALEK, J
    ARTYKOV, AM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 284 (2-3): : 433 - 438
  • [32] A HIGH-RESOLUTION DELAY-LINE READOUT FOR MICROCHANNEL PLATES
    SIEGMUND, OHW
    LAMPTON, ML
    RAFFANTI, R
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 476 - 485
  • [33] LARGE DRIFT TUBE ARRAYS WITH EXTERNAL DELAY-LINE READOUT
    BROLL, C
    CHARVEYS, A
    DECLAIS, Y
    FAVIER, J
    LEBEAU, M
    MOYNOT, M
    PERROT, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03): : 385 - 395
  • [34] RECENT DEVELOPMENTS IN DELAY-LINE READOUT OF MULTIWIRE PROPORTIONAL CHAMBERS
    PEREZMEN.V
    PARKER, SI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 45 - 50
  • [35] ALTERNATIVE APPROACHES TO DELAY-LINE READOUT FOR MULTIWIRE PROPORTIONAL CHAMBERS
    CIPRIANI, F
    GABRIEL, A
    KOCH, MHJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2): : 286 - 291
  • [36] SYNCHRONOUS DELAY-LINE DETECTOR PROVIDES WIDEBAND PERFORMANCE
    LUTZ, JF
    MICROWAVES & RF, 1982, 21 (12) : 71 - &
  • [37] Imaging mass spectrometry using a delay-line detector
    Froesch, Martin
    Luxembourg, Stefan L.
    Verheijde, Duncan
    Heeren, Ron M. A.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2010, 16 (01) : 35 - 45
  • [38] A HIGH-COUNT RATE AREA DETECTOR WITH MULTIPLE DELAY-LINE READOUT FOR X-RAY CRYSTALLOGRAPHY
    KOIKE, M
    HASEGAWA, K
    MOCHIKI, K
    OGAWA, T
    HASHIZUME, H
    IITAKA, Y
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C411 - C411
  • [39] DRIFT CHAMBERS WITH DELAY-LINE READOUT OPERATED IN THE LIMITED STREAMER MODE
    DAUBIE, E
    DEFONTAINES, F
    GRARD, F
    KESTEMAN, J
    PINGOT, O
    POIRET, C
    DECLERCQ, C
    ETIENNE, L
    GOORENS, B
    LEMONNE, J
    TAVERNIER, S
    VANBEEK, G
    VANDERVELDE, C
    VANDONINCK, W
    VANLANCKER, L
    WICKENS, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3): : 435 - 442
  • [40] IMAGING PROPERTIES OF A DELAY-LINE READOUT USING LARGE MICROCHANNEL PLATES
    SHEPHERD, JA
    SOBOTTKA, SE
    WILLIAMS, MB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 154 - 157