A MICROSTRIP DETECTOR WITH DELAY-LINE READOUT

被引:1
|
作者
BARBOSA, AF [1 ]
RIEKEL, C [1 ]
WATTECAMPS, P [1 ]
机构
[1] CNPQ,CBPF,RIO DE JANEIRO,BRAZIL
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 01期
关键词
D O I
10.1063/1.1142685
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Principal limitations of position sensitive gasfilled detectors for x-ray synchrotron radiation applications are the counting rate and the positional resolution. Improvements in both areas are expected with microstrip technology. First results of a linear position sensitive microstrip detector with delay line readout are shown, and the possibility to achieve two-dimensional localization is evaluated.
引用
收藏
页码:667 / 669
页数:3
相关论文
共 50 条
  • [1] Study of delay-line readout for GEM detector
    Zhou, Yi
    Li, Cheng
    Sun, Yongjie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 71 - 76
  • [2] FPGA implementation of a delay-line readout system for a particle detector
    Seferiadis, G
    Pouchet, M
    Gough, MP
    MEASUREMENT, 2006, 39 (01) : 90 - 99
  • [3] Study of Delay-line Readout for Boron Coated Straw detector
    Yu, Hao
    Gong, Hui
    Wang, Yongqiang
    Wang, Xuewu
    Li, Jianmin
    Li, Yuanjing
    Kang, Kejun
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [4] PROPORTIONAL CHAMBERS WITH DELAY-LINE READOUT IN THE MD-1 DETECTOR
    AULCHENKO, VM
    BONDAR, AE
    FILIMONOV, GS
    KOLACHEV, GM
    MINAKOV, GD
    ONUCHIN, AP
    PANIN, VS
    RODYAKIN, VA
    TELNOV, VI
    ZHILICH, VN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3): : 267 - 271
  • [5] Two-dimensional GEM imaging detector with delay-line readout
    Guedes, GP
    Breskin, A
    Chechik, R
    Vartsky, D
    Bar, D
    Barbosa, AF
    Marinho, PRB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03): : 473 - 483
  • [6] DELAY-LINE READOUT FOR MULTICELL DETECTORS
    DITTA, J
    KURODA, K
    NEMOZ, C
    SILLOU, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 250 (03): : 539 - 542
  • [7] DELAY-LINE READOUT FOR DRIFT CHAMBERS
    KREHBIEL, H
    WARMING, P
    ELSEN, E
    NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (1-2): : 347 - 351
  • [8] DELAY-LINE READOUT FOR PROPORTIONAL CHAMBERS
    RINDI, A
    PEREZMEN.V
    WALLACE, RI
    NUCLEAR INSTRUMENTS & METHODS, 1970, 77 (02): : 325 - +
  • [9] DELAY-LINE READOUT DRIFT CHAMBERS
    ATENCIO, LG
    AMANN, JF
    BOUDRIE, RL
    MORRIS, CL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 187 (2-3): : 381 - 386
  • [10] DELAY-LINE READOUT OF MICROCHANNEL PLATES
    SOBOTTKA, SE
    WILLIAMS, MB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 348 - 351