FLUORESCENCE LIFETIME MEASUREMENTS TO MONITOR MEMBRANE LIPID MIXING

被引:11
|
作者
BURGESS, SW [1 ]
LENTZ, BR [1 ]
机构
[1] UNIV N CAROLINA,DEPT BIOCHEM & BIOPHYS,CHAPEL HILL,NC 27599
关键词
D O I
10.1016/0076-6879(93)20072-B
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This chapter describes fluorescence lifetime measurements to monitor membrane lipid mixing. The only lipid mixing assay utilizing an intensive probe property is the DPHpPC fluorescence. Several fluorescent probes have been developed to monitor the intermembrane mixing of lipids during membrane fusion. The chapter explains how fluorescence lifetime measurements are used to monitor lipid exchange in model membrane systems induced to fuse by polyethylene glycol (PEG). It also examines the features of the probe, which make it useful not only for this fusion assay, but also as a probe for fusion-independent lipid exchange, phase separation, and formation of membrane domains. The aspects of the technique that limit its effectiveness as a tool for studying membrane fusion or the other membrane processes are also mentioned. to monitor the mixing of membrane phospholipid compartments by using the DPHpPC fluorescent lifetime lipid mixing assay, calibration curves must be generated by measuring the lifetime of the probe at different lipid/probe ratios. Because the lifetime of a fluorophore is dependent on the environment in which it resides, separate calibration curves must be generated for each lipid system studied. © 1993
引用
收藏
页码:42 / 50
页数:9
相关论文
共 50 条
  • [21] FLUORESCENCE LIFETIME MEASUREMENTS OF MERCURY PROTEIN COMPLEXES
    PESEK, JJ
    ABPIKAR, H
    BECKER, JF
    APPLIED SPECTROSCOPY, 1988, 42 (03) : 473 - 477
  • [22] Fluorescence Lifetime Imaging for viscosity and diffusion measurements
    Suhling, Klaus
    Teijeiro-Gonzalez, Yurema
    Steinmark, I. Emilie
    James, Arjuna L.
    Economou, Augoustina M.
    Yahioglu, Gokhan
    Le Marois, Alix
    Hirvonen, Liisa M.
    Nedbal, Jakub
    Levitt, James A.
    Chung, Pei-Hua
    Dreiss, Cecile A.
    Beavil, Andrew J.
    Beavil, Rebecca L.
    Ortiz-Zapater, Elena
    Lorenz, Christian D.
    Parsons, Maddy
    Crnjar, Alessandro
    Cornell, Bethan
    Molteni, Carla
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XIX, 2019, 10882
  • [23] Fluorescence lifetime measurements at the human fundus.
    Schweitzer, D
    Kolb, A
    Hammer, M
    Loesch, A
    Holz, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S62 - S62
  • [24] Spectrally resolved fluorescence lifetime and FRET measurements
    Kelbauskas, Laimonas
    Dietrich, Sascha
    Hoffmann, Birgit
    Zimmer, Thomas
    Benndorf, Klaus
    Becker, Wolfgang
    Bergmann, Axel
    Kloecker, Nikolaj
    Biskup, Christoph
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES VI, 2006, 6089
  • [25] Fluorescence lifetime measurements and spectral analysis of adamantyldiazirine
    Buterbaugh, JS
    Toscano, JP
    Weaver, WL
    Gord, JR
    Hadad, CM
    Gustafson, TL
    Platz, MS
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (15) : 3580 - 3591
  • [27] Investigations on exponential lifetime measurements for fluorescence thermometry
    Fernicola, VC
    Rosso, L
    Galleano, R
    Sun, T
    Zhang, ZY
    Grattan, KTV
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (07) : 2938 - 2943
  • [28] INSTRUMENT FOR VACUUM UV FLUORESCENCE LIFETIME MEASUREMENTS
    LYKE, RL
    WARE, WR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (03) : 320 - 326
  • [29] Multi-dimensional fluorescence lifetime measurements
    Biskup, Christoph
    Hoffmann, Birgit
    Kelbauskas, Laimonas
    Zimmer, Thomas
    Dietrich, Sascha
    Becker, Wolfgang
    Bergmann, Axel
    Kloecker, Nikolaj
    Benndorf, Klaus
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES VII, 2007, 6442
  • [30] Double-pulse fluorescence lifetime measurements
    Buist, AH
    Muller, M
    Gijsbers, EJ
    Brakenhoff, GJ
    Sosnowski, TS
    Norris, TB
    Squier, J
    JOURNAL OF MICROSCOPY-OXFORD, 1997, 186 : 212 - 220