Example calculation of the sound insulation of a floor slab between residential units according to DIN 4109-2:2016

被引:0
作者
Naumann, Kai [1 ]
Schoch, Torsten [1 ]
机构
[1] Xella Technol & Forschungsgesellschaft mbH, Hohes Steinfeld 1, D-14797 Kloster Lehnin, Germany
关键词
building acoustics; sound insulation; autoclaved aerated concrete blocks; massive building; homogeneous building materials; masonry; apartment block; joint;
D O I
10.1002/dama.201600697
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The DIN 4109 series of standards has been revised in recent years and harmonised with European design codes. After the drafts of DIN 4109 were issued in November 2013, the documents shall now be finally published in summer 2016. The calculation procedure according to DIN 4109-2 is based on the simplified procedure from EN 12354:2000, in which the noise transmission routes are calculated individually, similarly to the calculation for framed buildings according to supplement 1 to DIN 4109. The procedure according to DIN 4109-2 is based on formulae, which are filled with figures from the building element catalogue of parts 3-2 to 3-6. This article shows examples of calculation steps for the determination of the weighted airborne sound reduction R'(w),(R) according to DIN 4109-2:2016 for a floor slab between residential units.