Sensitive Voltammetric Method for Piroxicam Determination in Pharmaceutical, Urine and Tap Water Samples using an Anodically Pretreated Boron-Doped Diamond Electrode

被引:1
作者
Rosseto, Hallyssonn Augusto Pires [1 ]
Matos, Roberto [2 ]
Medeiros, Roberta Antigo [2 ]
机构
[1] Univ Estadual Oeste Parana Unioeste, Ctr Engn & Ciencias Exatas, BR-85903000 Toledo, PR, Brazil
[2] Univ Estadual Londrina, Ctr Ciencias Exatas, Dept Quim, CP 10-011, BR-86057970 Londrina, PR, Brazil
来源
BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY | 2018年 / 5卷 / 18期
关键词
anti-inflammatory; anodic pretreatment; BDD electrode; square-wave voltammetry; electroanalytical method;
D O I
10.30744/brjac.2179-3425.2018.5.18.40-50
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid voltammetric method for piroxicam (PRX) determination was developed using an anodically pretreated boron-doped diamond electrode and the square-wave voltammetric technique. Analytical curves were obtained for PRX concentrations from 0.50 to 11.0 mu mol L-1, with detection limits of 0.16 mu mol L-1. The proposed method was successfully applied in the determination of PRX in pharmaceutical formulations (tablets), with results similar to those obtained using a reference spectrophotometric method (at a confidence level of 95%), and in the recovery of PRX in synthetic urine and tap water samples. Comparative to other electroanalytical methods based on different electrodes, the method yielded good results, being adequate for PRX determination in different samples with the advantage that it involves the use of a non-modified electrode.
引用
收藏
页码:40 / 50
页数:11
相关论文
共 43 条
[1]   VOLTAMMETRIC DETERMINATION OF PIROXICAM IN MICELLAR MEDIA BY USING CONVENTIONAL AND SURFACTANT CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODES [J].
ACUNA, JA ;
DELAFUENTE, C ;
VAZQUEZ, MD ;
TASCON, ML ;
SANCHEZBATANERO, P .
TALANTA, 1993, 40 (11) :1637-1642
[2]  
Amin AS, 2010, B CHEM SOC ETHIOPIA, V24, P121
[3]   A multidimensional high performance liquid chromatography method coupled with amperometric detection using a boron-doped diamond electrode for the simultaneous determination of sulfamethoxazole and trimethoprim in bovine milk [J].
Andrade, Leonardo S. ;
de Moraes, Marcela C. ;
Rocha-Filho, Romeu C. ;
Fatibello-Filho, Orlando ;
Cass, Quezia B. .
ANALYTICA CHIMICA ACTA, 2009, 654 (02) :127-132
[4]  
[Anonymous], VAL AN PROC TEXT MET
[5]   Carbon ceramic electrode incorporated with zeolite ZSM-5 for determination of Piroxicam [J].
Asadpour-Zeynali, Karim ;
Majidi, Mir Reza ;
Zarifi, Mitra .
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2010, 8 (01) :155-162
[6]   A glassy carbon electrode modified with MCM-41/nickel hydroxide nanoparticle/multiwalled carbon nanotube composite as a sensor for the simultaneous determination of dopamine, piroxicam, and cefixime [J].
Babaei, Ali ;
Afrasiabi, Mohammad .
IONICS, 2015, 21 (06) :1731-1740
[7]   A Sensitive Simultaneous Determination of Epinephrine and Piroxicam Using a Glassy Carbon Electrode Modified with a Nickel Hydroxide Nanoparticles/Multiwalled Carbon Nanotubes Composite [J].
Babaei, Ali ;
Sohrabi, Masoud ;
Afrasiabi, Mohammad .
ELECTROANALYSIS, 2012, 24 (12) :2387-2394
[8]   Development and Validation of an HPLC Method for the Simultaneous Analysis of 23 Selected Drugs Belonging to Different Therapeutic Groups in Human Urine Samples [J].
Baranowska, Irena ;
Markowski, Piotr ;
Baranowski, Jacek .
ANALYTICAL SCIENCES, 2009, 25 (11) :1307-1313
[9]  
Beltagi AM, 2007, CHEM ANAL-WARSAW, V52, P387
[10]   Assessments of the Effect of Increasingly Severe Cathodic Pretreatments on the Electrochemical Activity of Polycrystalline Boron-Doped Diamond Electrodes [J].
Brocenschi, Ricardo F. ;
Hammer, Peter ;
Deslouis, Claude ;
Rocha-Filho, Romeu C. .
ANALYTICAL CHEMISTRY, 2016, 88 (10) :5363-5368