HIGH-FREQUENCY VOLUME COILS FOR CLINICAL NMR IMAGING AND SPECTROSCOPY

被引:296
作者
VAUGHAN, JT [1 ]
HETHERINGTON, HP [1 ]
OTU, JO [1 ]
PAN, JW [1 ]
POHOST, GM [1 ]
机构
[1] UNIV WISCONSIN,DEPT PHYS,WAUKESHA,WI
关键词
HIGH FREQUENCY MR VOLUME COILS; TUNABLE COAXIAL CAVITY; QUADRATURE COIL; DOUBLE TUNED;
D O I
10.1002/mrm.1910320209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A tuned transmission line resonator has been developed in theory and in practical design for the clinical NMR volume coil application at 4.1 tesla. The distributed circuit transmission line resonator was designed for high frequency, large conductive volume applications where conventional lumped element coil designs perform less efficiently. The resonator design has made use of a resonant coaxial cavity, which could be variably tuned to the Larmor frequency of interest by tunable transmission line elements. Large head- and body-sized volumes, high efficiencies, and broad tuning ranges have been shown to be characteristic of the transmission line resonator to frequencies of 500 MHz. The B-1 homogeneity of the resonator has been demonstrated to be a function of the electromagnetic properties of the load itself. By numerically solving Maxwell's equations for the fully time-dependent B-1 field, coil homogeneity was predicted with finite element models of anatomic structure, and inhomogeneities corrected for. A how-to exposition of coil design and construction has been included. Simple methods of quadrature driving and double tuning the transmission line resonator have also been presented. Human head images obtained with a tuned transmission line resonator at 175 MHz have clearly demonstrated uncompromised high field advantages of signal-to-noise and spatial resolution.
引用
收藏
页码:206 / 218
页数:13
相关论文
共 27 条
[1]  
Barfuss H, 1990, NMR Biomed, V3, P31, DOI 10.1002/nbm.1940030106
[2]  
Bomsdorf H, 1988, NMR Biomed, V1, P151, DOI 10.1002/nbm.1940010308
[3]  
CHATTERJEE R, 1986, ELEMENTS MICROWAVE E
[4]  
Chipman RA., 1968, THEORY PROBLEMS TRAN
[5]  
DUCK FA, 1990, PHYSICAL PROPERTIES
[6]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[7]  
Harrington R. F., 1961, TIME HARMONIC ELECTR
[8]  
HETHERINGTON HP, 1993, 12TH P SMRM ANN M, P901
[9]  
HETHERINGTON HP, 1993, J MAGN RESON IMAGI P, V3, P313
[10]  
KUZNIECKY R, 1993, 12TH P SMRM ANN M NE, P484